(1) Background: This study investigated the influence of Bis-GMA, TEGDMA, UDMA, and two different polyethylene glycol (PEG)-containing, UDMO-based co-monomers on the Young’s modulus and flexural strength, degree of methacrylate C=C double bond conversion and residual monomer elution of experimental dental resins. (2) Methods: Urethane methacrylate-based monomer was synthesised via a radical chain growth polymerization mechanism using PEG in order to improve the mechanical properties. Dental resins were formulated using Bis-GMA, UDMA, or UDMO as base monomers combined with TEGDMA as a dilution monomer and DMAEM + CQ as the photo-initiator system. Degree of conversion (DC), mechanical properties, and residual monomer content of light-activated methacrylate resin formulations were evaluated and statistically analysed by ANOVA and a Tukey’s test. (3) Results: PEG-containing UDMO resins had lower Young’s modulus and elastic strength than UDMA-derived resin for all irradiation times. The highest DC (67,418%) was observed for the PEG-containing UDMO-based resin formulation when light cured for 40 s. For all samples, DC increased with the photo-polymerization time. The amount of residual monomer decreased after increasing the light-curing period from 20 to 40 s, resin with UDMO content 0.01 mol of PEG having the smallest amount of free eluted monomer. (4) Conclusions: A strong structure–property relationship exists in photo-cured dimethacrylate-based dental resins. The time and quantity of the photochemical initiation system can influence the physical–mechanical properties of the resins but also the monomers in their composition.
The intent of the KAP (knowledge, attitude, practices) survey is to collect information about a specific target group related to their knowledge, what they consider to be known, and what they do about a particular topic. The aim of this study was to identify the level of importance of oral health, especially the level of knowledge, attitude and practices of rural patients around Cluj-Napoca, Romania. Material and methods: A questionnaire consisting of five parts was used, trying to assess the self-perception of oral health, knowledge and attitude towards oral health, dental hygiene practices and eating habits. A clinical examination was also performed in order to identify the number of missing teeth, the caries and the presence of calculus. Results: The study revealed that most patients have an average and good self-perception of oral health, although three-quarters of them have calculus deposits, and about half of them have more than three carious lesions and at least one extracted tooth. There is also a discrepancy between declared knowledge of oral health, eating habits and dental practices. Conclusions: The basic knowledge of rural patients about oral health can be considered satisfactory, but the practices, unfortunately, do not reflect this knowledge.
(1) Background: the current study investigated three nanohybrid composites: two commercial products ClearfilMajestyTM (CM) and HarmonizeTM (HU), compared with an experimental product PS2. (2) Methods: Two sample types were molded using Teflon dies. The first sample type was represented by standard discs (20 mm diameter and 2 mm thickness) (n = 60, 20/each material), used for surface conditioning investigation, specifically roughness monitoring and color stability analysis using AFM and the CIELab test, respectively. The second sample type was a standard cylindrical specimen (4 mm diameter and 6 mm height) for compression testing (n = 60, 20/each material). After complete polymerization, the samples were ground with sandpaper and further polished. The filler size and distribution in the polymer matrix were investigated with SEM. Data were statistically analyzed using the Anova Test followed by Tukey’s post hoc test on the Origin Lab 2019 software produced by OriginLab Corporation, Northampton, MA, USA. (3) Results: A mono-disperse system was identified in HU samples, while CM and PS2 revealed both nano- and microfiller particles. The samples’ observation after immersion in coffee and tea indicated that a lower roughness combined with optimal filler lamination within the polymer matrix assured the best color preservation. The compression strength was lower for the HU sample, while higher values were obtained for the complex filler systems within CM and PS2. (4) Conclusions: the behavior of the investigated nanohybrid composites strongly depends on the microstructural features.
Introduction: Several methods are currently available for providing a preview of the prosthodontic treatment, including computer simulations, 3D models, wax-ups, and mock-ups. The aim of this study is to compare the aesthetic aspects and assessment of conventional versus digital prefigurative methods. Methods: The study included 5 patients and 3 observers, for each of whom a wax-up was made in both the conventional and digital techniques. The analog method, which implied a mock-up molding with a silicone matrix of the wax-up, was compared to a digital workflow, which consisted of a mock-up milling from a digital design. The patient’s clinical mock-ups were recorded with digital photographs and assessed for nine different criteria by three observers. Results: The analysis has shown a balanced assessment of the aesthetic criteria without any significant difference between the analog and digital prefigurative methods. Conclusions: Between the two wax-ups (conventional and digital), there were some variations in smile and dental criteria; however, the obtained data were very similar. When it comes to the smile criteria, the general average grades of the mock-ups conducted using the conventional method are slightly higher than the ones using the digital technique.
Background and Objectives: The aim of this study was to compare the accuracy of three types of electronic apex locators (EALs) when two different concentrations of NaOCl irrigation solutions are used by two operators. Materials and Methods: After creating the access cavities for 20 single rooted extracted teeth, the actual canal length (ACL) of each canal was determined visually using a #10 file and magnification. The teeth were subsequently inserted in plastic molds filled with alginate. The electronic measurement of root canal length (EWL) was performed using three different electronic apex locators: Root ZX II, Apex ID, and Dual Pex. Two independent operators, an endodontic specialist with 20 years practice and an undergraduate student in the final year of study, performed the irrigation procedures with two different concentrations of NaOCl (2% and 5.25%), and then measured the EWL using each of the EALs. The accuracy of all EALs, was determined in each case by subtracting the EWL from the ACL. Statistical analyses were performed using one-way ANOVA test. Results: In the presence of 2% NaOCl solution, for a margin error of ±0.5 mm, Root ZX II, Apex ID, and Dual Pex presented an accuracy of 90%, 80%, and 85% respectively. The increase in the concentration of the irrigation solution affected the accuracy of Root ZX II and Apex ID for both operators, diminishing it to 75% for the same margin error, but improved Dual Pex’s accuracy to 100%. Conclusions: The best accuracy in working length determination was obtained by Root ZX II for 2% NaOCl solution and by Dual Pex for 5.25% NaOCl solution with no significant statistical difference when compared.
The aim of the present study was to obtain experimental infiltration materials, intended for the treatment of dental white spots, and to investigate them. Two series of infiltrants (P1–P6)/(P1F–P6F) were obtained, based on different monomer mixtures, without/with glass filler (with fluoride release ability). Each infiltrant from the second series contained the same amount of glass powder, and each infiltrant from the (P–PF) group contained the same resin composition. The characteristics of the experimental infiltrants were investigated by degree of conversion (DC), mechanical strength, water sorption (WS), and fluoride release, in addition to residual monomer for (P1F–P6F) infiltrants. The results were compared with those obtained for commercial Icon infiltrant. For the experimental infiltrants, without/with filler, the recorded DC was in the range of 58.27–89.70%/60.62–89.99%, compared with Icon (46.94%) 24 h after polymerization. The release of fluoride depends on the permeability of the polymer matrix, with respect to the water sorption, which may help to diffuse ions in the storage medium but which can also influence the release of residual monomers. The highest flexural strengths were recorded for the (TEGDMA/HEMA/Bis-GMA) infiltrants (133.94 ± 16.389 MPa/146.31 ± 7.032 MPa). The best experimental infiltrants were P2 and P2F (Bis-GMA/HEMA/TEGDMA).