Takashi Kamiyama

Prof. Dr. Takashi Kamiyama


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TKTakashi Kamiyama
Takashi Kamiyama
KHKazuma Hirano
Kazuma Hirano
HSHirotaka Sato
Hirotaka Sato
KOKanta Ono
Kanta Ono
YSYuta Suzuki
Yuta Suzuki
YSYasushi Saito
Yasushi Saito
In neutron transmission spectroscopic imaging, the transmission spectrum of each pixel on a two-dimensional detector is analyzed and the real-space distribution of microscopic information in an object is visualized with a wide field of view by mapping the obtained parameters. In the analysis of the transmission spectrum, since the spectrum can be classified with certain characteristics, it is possible for machine learning methods to be applied. In this study, we selected the subject of solid–liquid phase fraction imaging as the simplest application of the machine learning method. Firstly, liquid and solid transmission spectra have characteristic shapes, so spectrum classification according to their fraction can be carried out. Unsupervised and supervised machine learning analysis methods were tested and evaluated with simulated datasets of solid–liquid spectrum combinations. Then, the established methods were used to perform an analysis with actual measured spectrum datasets. As a result, the solid–liquid interface zone was specified from the solid–liquid phase fraction imaging using machine learning analysis.

4 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YSYosuke Sakurai
Yosuke Sakurai
HSHirotaka Sato
Hirotaka Sato
NANozomu Adachi
Nozomu Adachi
SMSatoshi MOROOKA
Satoshi MOROOKA
Yoshikazu TodakaYoshikazu Todaka
Yoshikazu Todaka
TKTakashi Kamiyama
Takashi Kamiyama
As a new method for evaluating single crystals and oligocrystals, pulsed neutron Bragg-dip transmission analysis/imaging method is being developed. In this study, a single Bragg-dip profile-fitting analysis method was newly developed, and applied for analyzing detailed inner information in a crystalline grain position-dependently. In the method, the spectrum profile of a single Bragg-dip is analyzed at each position over a grain. As a result, it is expected that changes in crystal orientation, mosaic spread angle and thickness of a perfect crystal can be evaluated from the wavelength, the width and the integrated intensity of the Bragg-dip, respectively. For confirming this effectiveness, the method was applied to experimental data of position-dependent Bragg-dip transmission spectra of a Si-steel plate consisting of oligocrystals. As a result, inner information of multiple crystalline grains could be visualized and evaluated. The small change in crystal orientation in a grain, about 0.4°, could be observed by imaging the Bragg-dip wavelengths. By imaging the Bragg-dip widths, both another grain and mosaic block in a grain were detected. Furthermore, imaging results of the integrated intensities of Bragg-dips were consistent with the results of Bragg-dip width imaging. These small crystallographic changes have not been observed and visualized by previous Bragg-dip analysis methods.

5 January 2020 in Materials Research Proceedings
Verified
Conference Paper
Open access
PDF file
TKTakashi Kamiyama
Takashi Kamiyama
KNK. Nittoh
K. Nittoh
KTK. Takada
K. Takada
Among various kinds of detectors being developed for neutron transmission imaging, Neutron Image Intensifier (NII) is still a promising option in terms of field of view and sensitivity. Since NII has a position resolution higher than 0.1 mm, it can be expected to obtain a high-sensitivity and high-gradation fine image with a camera to be combined [1]. In this research, we selected CMOS cameras for industrial applications with linearity over a wide sensitivity range, and examined the performance of the camera, especially the cooling effect of the sensor which is important in long-time measurement. Based on this result, we developed a portable imaging system that compactly integrates a cooled camera with NII, and constructed a system that can be used quickly in various neutron facilities.

16 July 2021
Verified
Preprint
Open access
YAYuta Abe
Yuta Abe
Tetsuya KaiTetsuya Kai
Tetsuya Kai
YTYusuke Tsuchikawa
Yusuke Tsuchikawa
YMYoshihiro Matsumoto
Yoshihiro Matsumoto
JPJoseph Don Parker
Joseph Don Parker
ISIkken Sato
Ikken Sato
Boron carbide (B~4~C) is used as neutron absorbing material in Boiling Water Reactor (BWR)s and Fast Breeder Reactors (e.g., Fukushima Dai-ichi (1F) Nuclear Power Plant). Since the hardness of fuel debris containing boride from B~4~C pellet in control blade is estimated to be two times higher as that of oxide, such as UO~2~ and ZrO~2~, it is necessary to select an efficient and