Lukáš Malena

Mr. Lukáš Malena

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
LMLukáš Malena
Lukáš Malena
Ondrej FiserOndrej Fiser
Ondrej Fiser
PSPaul R. Stauffer
Paul R. Stauffer
TDTomas Drizdal
Tomas Drizdal
JVJan Vrba
Jan Vrba
DVDavid Vrba
David Vrba
The use of microwave technology is currently under investigation for non-invasive estimation of glycemia in patients with diabetes. Due to their construction, metamaterial (MTM)-based sensors have the potential to provide higher sensitivity of the phase shift of the S21 parameter (∠S21) to changes in glucose concentration compared to standard microstrip transmission line (MSTL)-based sensors. In this study, a MSTL sensor and three MTM sensors with 5, 7, and 9 MTM unit cells are exposed to liquid phantoms with different dielectric properties mimicking a change in blood glucose concentration from 0 to 14 mmol/L. Numerical models were created for the individual experiments, and the calculated S-parameters show good agreement with experimental results, expressed by the maximum relative error of 8.89% and 0.96% at a frequency of 1.99 GHz for MSTL and MTM sensor with nine unit cells, respectively. MTM sensors with an increasing number of cells show higher sensitivity of 0.62° per mmol/L and unit cell to blood glucose concentration as measured by changes in ∠S21. In accordance with the numerical simulations, the MTM sensor with nine unit cells showed the highest sensitivity of the sensors proposed by us, with an average of 3.66° per mmol/L at a frequency of 1.99 GHz, compared to only 0.48° per mmol/L for the MSTL sensor. The multi-cell MTM sensor has the potential to proceed with evaluation of human blood samples.

15 January 2025 in IEEE Sensors Journal
Verified
Journal Article
Open access
LMLukáš Malena
Lukáš Malena
OFOndrej Fiser
Ondrej Fiser
TDTomas Drizdal
Tomas Drizdal
TPTomas Pokorny
Tomas Pokorny
MNMarek Novak
Marek Novak
DVDavid Vrba
David Vrba
For a first time 20 human blood samples with varying glucose concentrations using previously introduced metamaterial microwave (MTM) sensors, which had been already tested with phantoms. The MTM sensors based on composite right/left-handed metamaterial transmission line showed a detectable phase shift in the forward transmission parameter (∠S21) which is related to the blood glucose concentration. Application of a novel biochemical approach introduces separate mathematical models based on gender, reflecting physiological difference in blood, which were further evidenced by measured variations in blood dielectric properties. This contributed to enhanced sensor performance as well as the professional sample preservation system. The accuracy of glucose concentration estimation was analyzed using mean absolute relative difference (MARD) and Parkes error grids. The MARD values for the Female and Male group reached 23 % and 29 % respectively. The findings demonstrate the potential of the MTM sensor for non-invasive glycemia monitoring.

17 August 2022 in Physica Medica
Verified
Journal Article
Open access
TDTomas Drizdal
Tomas Drizdal
MPMargarethus M. Paulides
Margarethus M. Paulides
KSKemal Sumser
Kemal Sumser
DVDavid Vrba
David Vrba
LMLukáš Malena
Lukáš Malena
GRGerard C. van Rhoon
Gerard C. van Rhoon
Hyperthermia is a cancer treatment in which the target region is heated to temperatures of 40-44 °C usually applying external electromagnetic field sources. The behavior of the hyperthermia applicators (antennas) in clinical practice should be periodically checked with phantom experiments to verify the applicator's performance over time. The purpose of this study was to investigate the application of photogrammetry reconstructions of 3D applicator position in these quality control procedure measurements. Photogrammetry reconstruction was applied at superficial hyperthermia scenario using the Lucite cone applicator (LCA) and phased-array heating in the head and neck region using the HYPERcollar3D. Wire-frame models of the entire measurement setups were created from multiple-view images and used for recreation of the setup inside 3D electromagnetic field simulation software. We evaluated applicator relation (Ra) between measured and simulated absolute specific absorption rate (SAR) for manually created and photogrammetry reconstructed simulation setups. We found a displacement of 7.9 mm for the LCA and 8.2 mm for the HYPERcollar3D setups when comparing manually created and photogrammetry reconstructed applicator models placements. Ra improved from 1.24 to 1.18 for the LCA and from 1.17 to 1.07 for the HYPERcollar3D when using photogrammetry reconstructed simulation setups. Photogrammetry reconstruction technique holds promise to improve measurement setup reconstruction and agreement between measured and simulated absolute SAR.

3 March 2022 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
DVDavid Vrba
David Vrba
LMLukáš Malena
Lukáš Malena
JAJakub Albrecht
Jakub Albrecht
JFJitka Fricova
Jitka Fricova
MAMartin Anders
Martin Anders
JVJan Vrba
Jan Vrba
In this paper, we monitored the accuracy of non-navigated application of repetitive Transcranial Magnetic Stimulation (rTMS) in 10 patients suffering from orofacial pain by using functional magnetic resonance (fMRI), computer modeling and numerical simulation. Through a unique process, each fMRI scan was used to define a Region of Interest (ROI) where the source of the orofacial pain was located, which was to be stimulated using rTMS. For each patient, MRI scans with a spatial resolution of 0.7 mm were converted into an anatomically accurate head model. The head model including the ROI was then co-registered with a model of the stimulation coil in an electromagnetic field numerical simulator. The accuracy of rTMS application was evaluated based on the calculations of electric field intensity distribution in the ROI. The research has yielded unique insight into ROIs (with average volume 904mm3) in patients with orofacial pain and has also extended further possibilities of human head MRI image semi-automatic segmentation. According to the calculations performed, the average ROI volume that was stimulated by an electric field with an intensity of over 80 V/m was only 4.4%, with the maximum ROI volume being 20.5%. Furthermore, a numerical study of the impact of coil rotation and translation was performed. It demonstrated a) the optimal placement of the stimulation coil can significantly increase the volume of the stimulated ROI up to 60% and b) patients with orofacial pain would need precise coil positioning with a navigation error lower than 10 mm. Due to an acceptable proccessing time of up to 6 hours, described numerical simulation opens up new options for precise rTMS treatment planning. This planning platform together withpatient-specific navigated rTMS, could lead to significant increase of treatment outcomes in patients suffering from orofacial pain.