This work presents a design and experimental validation of a compact ultrawideband (UWB) bowtie antenna and balanced-to-unbalanced (balun) circuit for medical microwave imaging (MWI) applications working in the frequency band of 1–6 GHz. The UWB balun is perpendicularly attached to the planar bowtie arms, whose dimensions were miniaturized by rounding the bowtie edges. The antenna reflection coefficient was lower than −12 dB for tissues with a higher water content. The antenna possesses a high radiation efficiency (over 80%) and very low backward radiation. The predicted and measured specific absorption rate (SAR) distributions together with the electric field $\vert E\vert $ distribution proved a symmetrical radiation pattern. The potential of the presented antenna element was demonstrated by successful reconstruction of the images from the measured data by MWI methods. For this purpose, an MWI system equipped with eight antennas was implemented. The radar approach was used to determine the region of interest (ROI) where the area for microwave tomography reconstruction was identified. The dielectric properties within the ROI were reconstructed by using the Born approximation method at 1 GHz. This confirmed that the antenna can be used as the basis for more accurate multifrequency MWI systems and can be implemented in UWB MWI hybrid systems.
The knowledge of frequency and temperature dependent dielectric properties of tissue is essential to develop ultra-wideband diagnostic technologies, such as a non-invasive temperature monitoring system during hyperthermia treatment. To this end, we characterized the dielectric properties of animal liver, muscle, fat and blood in the microwave frequency range from 0.5 GHz to 7 GHz and in the temperature range between 30 °C and 50 °C. The measured data were modeled to a two-pole Cole-Cole model and a second-order polynomial was introduced to fit the Cole-Cole parameters as a function of temperature. The parametric model provides access to the dielectric properties of tissue at any frequency and temperature in the specified range.
The aim of this work was to test microwave brain stroke detection and classification using support vector machines (SVMs). We tested how the nature and variability of training data and system parameters impact the achieved classification accuracy. Using experimentally verified numerical models, a large database of synthetic training and test data was created. The models consist of an antenna array surrounding reconfigurable geometrically and dielectrically realistic human head phantoms with virtually inserted strokes of arbitrary size, and different dielectric parameters in different positions. The generated synthetic data sets were used to test four different hypotheses, regarding the appropriate parameters of the training dataset, the appropriate frequency range and the number of frequency points, as well as the level of subject variability to reach the highest SVM classification accuracy. The results indicate that the SVM algorithm is able to detect the presence of the stroke and classify it (i.e., ischemic or hemorrhagic) even when trained with single-frequency data. Moreover, it is shown that data of subjects with smaller strokes appear to be the most suitable for training accurate SVM predictors with high generalization capabilities. Finally, the datasets created for this study are made available to the community for testing and developing their own algorithms.
The use of microwave technology is currently under investigation for non-invasive estimation of glycemia in patients with diabetes. Due to their construction, metamaterial (MTM)-based sensors have the potential to provide higher sensitivity of the phase shift of the S21 parameter () to changes in glucose concentration compared to standard microstrip transmission line (MSTL)-based sensors. In this study, a MSTL sensor and three MTM sensors with 5, 7, and 9 MTM unit cells are exposed to liquid phantoms with different dielectric properties mimicking a change in blood glucose concentration from 0 to 14 mmol/L. Numerical models were created for the individual experiments, and the calculated S-parameters show good agreement with experimental results, expressed by the maximum relative error of 8.89% and 0.96% at a frequency of 1.99 GHz for MSTL and MTM sensor with nine unit cells, respectively. MTM sensors with an increasing number of cells show higher sensitivity of 0.62° per mmol/L and unit cell to blood glucose concentration as measured by changes in . In accordance with the numerical simulations, the MTM sensor with nine unit cells showed the highest sensitivity of the sensors proposed by us, with an average of 3.66° per mmol/L at a frequency of 1.99 GHz, compared to only 0.48° per mmol/L for the MSTL sensor. The multi-cell MTM sensor has the potential to proceed with evaluation of human blood samples.
Due to the clinically proven benefit of hyperthermia treatments if added to standard cancer therapies for various tumor sites and the recent development of non-invasive temperature measurements using magnetic resonance systems, the hyperthermia community is convinced that it is a time when even patients with brain tumors could benefit from regional microwave hyperthermia, even if they are the subject of a treatment to a vital organ. The purpose of this study was to numerically analyze the ability to achieve a therapeutically relevant constructive superposition of electromagnetic (EM) waves in the treatment of hyperthermia targets within the brain. We evaluated the effect of the target size and position, operating frequency, and the number of antenna elements forming the phased array applicator on the treatment quality. In total, 10 anatomically realistic 2D human head models were considered, in which 10 circular hyperthermia targets with diameters of 20, 25, and 30 mm were examined. Additionally, applicators with 8, 12, 16, and 24 antenna elements and operating frequencies of 434, 650, 915, and 1150 MHz, respectively, were analyzed. For all scenarios considered (4800 combinations), the EM field distributions of individual antenna elements were calculated and treatment planning was performed. Their quality was evaluated using parameters applied in clinical practice, i.e., target coverage (TC) and the target to hot-spot quotient (THQ). The 12-antenna phased array system operating at 434 MHz was the best candidate among all tested systems for HT treatments of glioblastoma tumors. The 12 antenna elements met all the requirements to cover the entire target area; an additional increase in the number of antenna elements did not have a significant effect on the treatment quality.
1 January 2021 in International Journal of Hyperthermia
To develop a head and neck hyperthermia phased array system compatible with a 1.5 T magnetic resonance (MR) scanner for noninvasive thermometry.We designed a dielectric-parabolic-reflector antenna ...