This work presents a design and experimental validation of a compact ultrawideband (UWB) bowtie antenna and balanced-to-unbalanced (balun) circuit for medical microwave imaging (MWI) applications working in the frequency band of 1–6 GHz. The UWB balun is perpendicularly attached to the planar bowtie arms, whose dimensions were miniaturized by rounding the bowtie edges. The antenna reflection coefficient was lower than −12 dB for tissues with a higher water content. The antenna possesses a high radiation efficiency (over 80%) and very low backward radiation. The predicted and measured specific absorption rate (SAR) distributions together with the electric field $\vert E\vert $ distribution proved a symmetrical radiation pattern. The potential of the presented antenna element was demonstrated by successful reconstruction of the images from the measured data by MWI methods. For this purpose, an MWI system equipped with eight antennas was implemented. The radar approach was used to determine the region of interest (ROI) where the area for microwave tomography reconstruction was identified. The dielectric properties within the ROI were reconstructed by using the Born approximation method at 1 GHz. This confirmed that the antenna can be used as the basis for more accurate multifrequency MWI systems and can be implemented in UWB MWI hybrid systems.
17 September 2010 in International Journal of Hyperthermia
For superficial hyperthermia a custom-built multi-applicator multi-amplifier superficial hyperthermia system operating at 433 MHz is utilised. Up to 6 Lucite Cone applicators can be used simultaneously to treat an area of 600 cm2. Temperatures are measured continuously with fibre optic multi-sensor probes. For patients with non-standard clinical problems, hyperthermia treatment planning is used to support decision making with regard to treatment strategy. In 74% of our patients with recurrent breast cancer treated with a reirradiation scheme of 8 fractions of 4 Gy in 4 weeks, combined with 4 or 8 hyperthermia treatments, a complete response is achieved, approximately twice as high as the CR rate following the same reirradation alone. The CR rate in tumours smaller than 30 mm is 80–90%, for larger tumours it is 65%. Hyperthermia appears beneficial for patients with microscopic residual tumour as well. To achieve high CR rates it is important to heat the whole radiotherapy field, and to use an adequate heating technique.
Clinical trials have shown that hyperthermia is a potent adjuvant to conventional cancer treatments, but the temperatures currently achieved in the clinic are still suboptimal. Hyperthermia treatment planning simulations have potential to improve the heating profile of phased-array applicators. An important open challenge is the development of an effective optimization procedure that enables uniform heating of the target region while keeping temperature below a threshold in healthy tissues. In this work, we analyzed the effectiveness and efficiency of a recently proposed optimization approach, i.e. focusing via constrained power optimization (FOCO), using 3D simulations of twelve clinical patient specific models. FOCO performance was compared against a clinically used particle swarm based optimization approach. Evaluation metrics were target coverage at the 25% iso-SAR level, target hotspot quotient, median target temperature (T50) and computational requirements. Our results show that, on average, constrained power focusing performs slightly better than the clinical benchmark ([Formula: see text]T50 [Formula: see text] °C), but outperforms this clinical benchmark for large target volumes ([Formula: see text]40 cm[Formula: see text], [Formula: see text]T50 [Formula: see text] °C). In addition, the results are achieved in a shorter time ([Formula: see text]%) and are repeatable because the approach is formulated as a convex optimization problem.
The aim of this work was to test microwave brain stroke detection and classification using support vector machines (SVMs). We tested how the nature and variability of training data and system parameters impact the achieved classification accuracy. Using experimentally verified numerical models, a large database of synthetic training and test data was created. The models consist of an antenna array surrounding reconfigurable geometrically and dielectrically realistic human head phantoms with virtually inserted strokes of arbitrary size, and different dielectric parameters in different positions. The generated synthetic data sets were used to test four different hypotheses, regarding the appropriate parameters of the training dataset, the appropriate frequency range and the number of frequency points, as well as the level of subject variability to reach the highest SVM classification accuracy. The results indicate that the SVM algorithm is able to detect the presence of the stroke and classify it (i.e., ischemic or hemorrhagic) even when trained with single-frequency data. Moreover, it is shown that data of subjects with smaller strokes appear to be the most suitable for training accurate SVM predictors with high generalization capabilities. Finally, the datasets created for this study are made available to the community for testing and developing their own algorithms.
16 October 2017 in International Journal of Hyperthermia
Purpose: In this study, we investigated the differences in hyperthermia treatment (HT) quality between treatments applied with different hyperthermia systems for sub-superficial tumours in the head and neck (H&N) region. Materials and methods: In 24 patients, with a clinical target volume (CTV) extending up to 6 cm from the surface, we retrospectively analysed the predicted HT quality achievable by two planar applicator arrays or one phased-array hyperthermia system. Hereto, we calculated and compared the specific absorption rate (SAR) and temperature distribution coverage of the CTV and gross tumour volume (GTV) for the Lucite cone applicator (LCA: planar), current sheet applicator (CSA: planar) and the HYPERcollar (phased-array). Results: The HYPERcollar provides better SAR coverage than planar applicators if the target region is fully enclosed by its applicator frame. For targets extending outside the HYPERcollar frame, sufficient SAR coverage (25% target coverage, i.e. TC25 ≥ 75%) can still be achieved using the LCA when the target is fully under the LCA aperture and not deeper than 50 mm from the patient surface. Conclusion: Simulations predict that the HYPERcollar (hence also its successor the HYPERcollar3D) is to be preferred over planar applicators such as LCA and current sheet applicator in sub-superficial tumours in the H&N region when used within specifications.
Biological studies and clinical trials show that addition of hyperthermia stimulates conventional cancer treatment modalities and significantly improves treatment outcome. This supra-additive stimulation can be optimized by adaptive hyperthermia to counteract strong and dynamic thermoregulation. The only clinically proven method for the 3D non-invasive temperature monitoring required is by magnetic resonance (MR) temperature imaging, but the currently available set of MR compatible hyperthermia applicators lack the degree of heat control required. In this work, we present the design and validation of a high-frequency (433 MHz ISM band) printed circuit board antenna with a very low MR-footprint. This design is ideally suited for use in a range of hyperthermia applicator configurations. Experiments emulating the clinical situation show excellent matching properties of the antenna over a 7.2% bandwidth ( S11 < −15 dB). Its strongly directional radiation properties minimize inter-element coupling for typical array configurations ( S21 < −23 dB). MR imaging distortion by the antenna was found negligible and MR temperature imaging in a homogeneous muscle phantom was highly correlated with gold-standard probe measurements (root mean square error: RMSE = 0.51 °C and R2 = 0.99). This work paves the way for tailored MR imaging guided hyperthermia devices ranging from single antenna or incoherent antenna-arrays, to real-time adaptive hyperthermia with phased-arrays.