Luca Barbieri

Luca Barbieri

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2017 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
AVAndrea Barbareschi Villa
Andrea Barbareschi Villa
LBLuca Barbieri
Luca Barbieri
GMGondola Marco
Gondola Marco
RMRoberto Malgesini
Roberto Malgesini
ALAndres R Leon-Garzon
Andres R Leon-Garzon
The corona effect, and in particular the Trichel phenomenon, is an important aspect of plasma physics with many technical applications, such as pollution reduction, surface and medical treatments. This phenomenon is also associated with components used in the power industry where it is, in many cases, the source of electro-magnetic disturbance, noise and production of undesired chemically active species. Despite the power industry to date using mainly alternating current (AC) transmission, most of the studies related to the corona effect have been carried out with direct current (DC) sources. Therefore, there is technical interest in validating numerical codes capable of simulating the AC phenomenon. In this work we describe a set of partial differential equations that are comprehensive enough to reproduce the distinctive features of the corona in an AC regime. The model embeds some selectable chemical databases, comprising tens of chemical species and hundreds of reactions, the thermal dynamics of neutral species and photoionization. A large set of parameters—deduced from experiments and numerical estimations—are compared, to assess the effectiveness of the proposed approach.

1 May 2017 in Journal of Computational Physics
Verified
Journal Article
Closed access
AVAndrea Barbareschi Villa
Andrea Barbareschi Villa
LBLuca Barbieri
Luca Barbieri
MGMarco Gondola
Marco Gondola
ALAndres R. Leon-Garzon
Andres R. Leon-Garzon
RMRoberto Malgesini
Roberto Malgesini

16 September 2014 in Computers & Fluids
Verified
Journal Article
Closed access
AVAndrea Barbareschi Villa
Andrea Barbareschi Villa
LBLuca Barbieri
Luca Barbieri
MGMarco Gondola
Marco Gondola
ALAndres R. Leon-Garzon
Andres R. Leon-Garzon
RMRoberto Malgesini
Roberto Malgesini

10 October 2019 in Polymers
Verified
Journal Article
Open access
PDF file
ALAndres R. Leon-Garzon
Andres R. Leon-Garzon
Giovanni DotelliGiovanni Dotelli
Giovanni Dotelli
MTMatteo Tommasini
Matteo Tommasini
Claudia BianchiClaudia Bianchi
Claudia Bianchi
Carlo PirolaCarlo Pirola
Carlo Pirola
LBLuca Barbieri
Luca Barbieri
Polymeric dielectrics are employed extensively in the power transmission industry, thanks to their excellent properties; however, under normal operating conditions these materials tend to degrade and fail. In this study, samples of low-density polyethylene, polypropylene, polymethyl methacrylate, and polytetrafluorethylene were subjected to corona discharges under nitrogen and air atmospheres. The discharges introduced structural modifications over the polymer surface. From a chemical perspective, the alterations are analogous among the non-fluorinated polymers (i.e., polyethylene (PE), polypropylene (PP), and polymethyl methacrylate (PMMA)). A simulation of the corona discharge allowed the identification of highly reactive species in the proximity of the surface. The results are consistent with the degradation of insulating polymers in high-voltage applications due to internal partial discharges that ultimately lead to the breakdown of the material.

23 January 2019 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
AVAndrea Barbareschi Villa
Andrea Barbareschi Villa
LBLuca Barbieri
Luca Barbieri
RMRoberto Malgesini
Roberto Malgesini
ALAndres R. Leon-Garzon
Andres R. Leon-Garzon
Internal partial discharges and electrical treeing are some of the main aging mechanisms of all the polymeric insulating materials present in the power net. A better understanding of this process calls for the development of more sophisticated simulation tools, based on the numerical solution of first principles equations, i.e., a set of partial differential equations. The accuracy of the predictions of these models heavily relies on the quality of the set of physical parameters used as, for example, the swarm parameters. A key aspect is the correct representation of the first electron availability which triggers the discharge. These electrons are mainly injected into the gas from the interface between the gas itself and the solid polymeric matrix by means of the Schottky effect. The work function is a very relevant parameter in defining this effect, and so the entire quality of the simulation process depends on it. In this work, we estimate the value of the work function, using electronic structure calculations, and we perform some parametric analyses to show how the discharge simulations are affected by the variation of this quantity. In particular, we assume that the polymeric material is polyethylene, which is used extensively in the electric power transmission industry. The discharge simulations produce some relevant data that can be compared against experimental data for validation purposes.

7 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
LBLuca Barbieri
Luca Barbieri
AVAndrea Barbareschi Villa
Andrea Barbareschi Villa
RMRoberto Malgesini
Roberto Malgesini
DPDaniele Palladini
Daniele Palladini
Christian LauranoChristian Laurano
Christian Laurano
To enhance grid reliability, weak points must be monitored. One of the weaknesses is the cable joints, which are prone to failure and can cause great losses from both a technical and economical point of view. Joints failures are usually caused by impurities unintentionally added during installation that cause partial discharges (PDs). In time, these discharges erode the insulation and generate treeing up to a destructive discharge between the conductor and the ground shield. For this reason, a method for the early detection of defects in joint installation and their online monitoring is required. A previously developed sensor was improved by adapting it for this purpose. It is based on the measurement of the induced current on a conductor due to a charge variation. It was experimentally tested on an actual joint in which defects were artificially introduced. Results show that the sensor is able to detect partial discharges. Moreover, a method for PD localization was developed. The first results show a coherency between the possible defect location, numerical simulations and historical background.