The phenomenon of high-frequency distortion (HFD) in the electric grids, at both low-voltage (LV) and medium-voltage (MV) levels, is gaining increasing interest within the scientific and technical community due to its growing occurrence and the associated impact. These disturbances are mainly injected into the grid by new installed devices, essential for achieving decentralized generation based on renewable sources. In fact, these generation systems are connected to the grid through power converters, whose switching frequencies are significantly increasing, leading to a corresponding rise in the frequency of the injected disturbances. HFD represents a quite recent issue, but numerous scientific papers have been published in recent years on this topic. Furthermore, various international standards have also covered it, to provide guidance on instrumentation and related algorithms and indices for the measurement of these phenomena. When measuring HFD in MV grids, it is necessary to use instrument transformers (ITs) to scale voltages and currents to levels fitting with the input stages of power quality (PQ) instruments. In this respect, the recently released Edition 2 of the IEC 61869-1 standard extends the concept of the IT accuracy class up to 500 kHz; however, the IEC 61869 standard family provides guidelines on how to test ITs only at power frequency. This paper provides an extensive review of literature, standards, and the main outputs of European research projects focusing on HFD and ITs. This preliminary study of the state-of-the-art represents an essential starting point for defining significant waveforms to test ITs and, more generally, to achieve a comprehensive understanding of HFD. In this framework, this paper provides a summary of the most common ranges of amplitude and frequency variations of actual HFD found in real grids, the currently adopted measurement methods, and the normative open challenges to be addressed.
To enhance grid reliability, weak points must be monitored. One of the weaknesses is the cable joints, which are prone to failure and can cause great losses from both a technical and economical point of view. Joints failures are usually caused by impurities unintentionally added during installation that cause partial discharges (PDs). In time, these discharges erode the insulation and generate treeing up to a destructive discharge between the conductor and the ground shield. For this reason, a method for the early detection of defects in joint installation and their online monitoring is required. A previously developed sensor was improved by adapting it for this purpose. It is based on the measurement of the induced current on a conductor due to a charge variation. It was experimentally tested on an actual joint in which defects were artificially introduced. Results show that the sensor is able to detect partial discharges. Moreover, a method for PD localization was developed. The first results show a coherency between the possible defect location, numerical simulations and historical background.
6 February 2023 in Modelling and Simulation in Materials Science and Engineering
Polymeric insulation employed in electrical power industry undergo irreversible and unpredictable ageing due to partial discharges (PDs). In particular, the dielectric properties of polyethylene (PE) used in high voltage cables are often compromised by the formation of electrical trees. In this work we assume that the propagation of treeing channels involves the injection of carbonic material into the gas interacting with the surface of the defect. Experimental characterizations proved that, in certain conditions, disordered graphitic carbon can form in some areas of the electrical trees, thus increasing surface conductivity and inhibiting PDs. The chemical mechanism involved in this process is yet to be clarified. Here we propose a model for this process. By means of a series of molecular dynamics simulations, we show how the chemisorption of gaseous molecules on a PE surface can lead to a bidimensional carbonic structure. The characterization of the density of states of such systems suggests that the presence of pure carbon adsorbed on the polymer causes an increase in surface conductivity.
10 February 2022 in Journal of Computational Physics
The integration of distributed energy resources and power electronic devices in modern power systems has led to significant power quality challenges, particularly the increasing of harmonic components in current and voltage waveforms. Accurate measurement of both fundamental and harmonic components is essential for grid stability, reliability, and efficient operation. Conventional inductive current and voltage transformers, while widely used, suffer from nonlinearities such as hysteresis and saturation, which degrade measurement accuracy, especially at harmonic frequencies. This paper presents a comprehensive literature review of compensation techniques aimed at improving the metrological performance of instrument transformers. It evaluates methods including Polynomial Harmonic Distortion compensation (PHD), SINusoidal characterization for DIstortion COMPensation (SINDICOMP and Extended SINDICOMP), Volterra INtegral Compensation for Instrument TrAnsformers (VINCITA), Artificial Neural Networks methods (ANN), tensor linearization, hardware-based solutions, and temperature compensation. Each technique is analysed in terms of computational complexity, real-time capability, model dependency, need for prior characterization, and scalability. The review highlights the trade-offs between model-free flexibility and model-based precision, offering insights into the selection of appropriate compensation strategies for enhancing harmonic measurement accuracy in modern power systems.
Composite insulators for high-voltage overhead lines have better performances and are lighter than traditional designs, especially in heavily polluted areas. However, since it is a relatively recent technology, reliable methods to perform live-line diagnostics are still under development, especially with regard to internal defects, which provide few external symptoms. Thermal cameras can be employed, but their use is not always straightforward as the sun radiation can hide the thermal footprint of internal degenerative effects. In this work, an optical E-field sensor has been used to diagnose the internal defects of a set of composite insulators (bandwidth 200 mHz–50 MHz, min. detectable E-field 100 V/m). Moreover, a modelling activity using finite elements has been carried out to identify the possible nature of the defects by comparing experimental E-field profiles with those simulated assuming a specific defect geometry. The results show that the sensor can detect the presence of an internal defect, since its presence distorts the E-field profile when compared to the profile of a sound insulator. Moreover, the measured E-field profiles are compatible with the corresponding simulated ones when a conductive defect is considered. However, it was observed that a defect whose conductivity is not at least two orders of magnitude greater than the conductivity of the surroundings remains undetected.