Nagananthini Ravichandran

Ms. Nagananthini Ravichandran

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2021 in Processes
Verified
Journal Article
Open access
PDF file
NRNagananthini Ravichandran
Nagananthini Ravichandran
Hady H. FayekHady H. Fayek
Hady H. Fayek
Eugen RUSUEugen RUSU
Eugen RUSU
The world has a target of achieving 100% renewable energy by the end of the century. This paper presents a case study to establish a new floating photovoltaic park (FPV) in Egyptian dams. In Egypt, two hydroelectric dams, namely High Dam and Aswan Reservoir, together produce 2.65 GW in the Upper-Egypt region. The addition of 5 MW FPV for each dam is simulated using the Helioscope software application. A comparison between the performance of the dams with and without adding the FPV is presented in terms of the evaporation rate and total produced energy. A comparison between different types of FPV, namely polycrystalline, thin film and mono-crystalline in the two dams are also presented. The results show that installing FPV in the Egyptian dams will drive the dams to better performance in terms of carbon dioxide reduction, water-saving from reducing evaporation and increasing hydropower generation.

27 June 2024 in Electric Power Systems Research
Verified
Journal Article
Open access
NRNagananthini Ravichandran
Nagananthini Ravichandran
DPDaniela Proto
Daniela Proto
AAAmedeo Andreotti
Amedeo Andreotti

8 February 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
RARamesh Kumar A
Ramesh Kumar A
KCKumar Chandrasekaran
Kumar Chandrasekaran
Eugen RUSUEugen RUSU
Eugen RUSU
NRNagananthini Ravichandran
Nagananthini Ravichandran
Hady H. FayekHady H. Fayek
Hady H. Fayek
A hybrid microgrid system is modelled using HOMER-Pro software for real-time load data and available energy sources at Elapakkam village under Ramapuram substation, Kanchipuram, Tamil Nadu, India. Optimization approaches are applied for the selection of rating of the physical components, including solar PV systems, diesel generators, storage batteries, converters, inverters, and economic parameters such as system cost, fuel cost, and cash flow. The daily community load profile for the year 2018 was estimated based on data from TANGEDCO. Accordingly, the total load demand for the village represented 8760 lines of hourly load. The aim of this paper is to select an optimal-sized and reliable hybrid microgrid system to meet the load demands with available energy inputs. However, a comparison based on the cost of energy (COE) and the penetration of renewable energy is carried out for different case studies in the village with the economic-feasibility analysis of various countries. From this analysis, emissions cannot be completely avoided, they could be minimized by combining existing systems with renewable energy systems.

27 July 2023 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Open access
ESErika Stracqualursi
Erika Stracqualursi
Rodolfo ARANEORodolfo ARANEO
Rodolfo ARANEO
NRNagananthini Ravichandran
Nagananthini Ravichandran
Amedeo AndreottiAmedeo Andreotti
Amedeo Andreotti
Salvatore CelozziSalvatore Celozzi
Salvatore Celozzi
In this article, the effects of the variable height in overhead power lines are investigated with reference to the surges produced by direct and indirect lightning events. Simulations are carried out both by an implicit finite-difference time-domain scheme and by the commercial tool EMTP-RV. Differences in the waveforms computed by the two approaches are discussed and clarified. Additionally, the validity of the commonly adopted assumption of weakly varying vertical component of the incident electric field is investigated.

15 December 2021 in Machines
Verified
Journal Article
Open access
PDF file
KCKumar Chandrasekaran
Kumar Chandrasekaran
JJJ Jasper
J Jasper
STSundarsingh Jebaseelan Somasundaram David Thanasingh
Sundarsingh Jebaseelan Somasundaram David Thanasingh
SRSripriya Ramalingam
Sripriya Ramalingam
Hady H. FayekHady H. Fayek
Hady H. Fayek
Eugen RUSUEugen RUSU
Eugen RUSU
This article briefs about a smart multifunctional single-phase inverter control for a domestic solar photo voltaic (PV)-based distributed generation that can work in both a grid-connected mode and an islanded mode by making the inverter mimic the operation of a synchronous generator. The control objectives were threefold: to provide the required active and reactive power for normal operating conditions and under varying operating conditions, to maintain the rated voltage and the rated frequency for the islanded mode, and to switch between the two modes of operation with the least amount of disturbance for the system while behaving as a virtual synchronous generator (VSG). The control structure is divided into three major loops: the outermost loop responsible for power control, the middle loop responsible for voltage control, and the innermost loop responsible for current control. The proposed control methodology incorporates the functionalities of the grid-connected and the islanded-mode control into a single complex structure and thus provides support to the grid under abnormal conditions while providing good-quality power to consumers under grid failure. The efficacy of the system is good. The operation under various modes were simulated in MATLAB Simulink, and the proportional integral (PI) controllers used for current controllers were tuned using particle swarm optimization (PSO). It can be concluded that the control structure becoming complex is benefitted by the added advantages of the smart PV system. The smart domestic PV system helps the prosumer to actively provide frequency support and voltage support, adding frequency support to the existing multifunctional PV systems.

27 February 2025 in IEEE Access
Verified
Journal Article
Open access
NRNagananthini Ravichandran
Nagananthini Ravichandran
Daniela ProtoDaniela Proto
Daniela Proto
Fabio MottolaFabio Mottola
Fabio Mottola
Amedeo AndreottiAmedeo Andreotti
Amedeo Andreotti
This paper focuses on the identification of a proper protection strategy against lightning effects on overhead distribution lines. Particularly, a multi-objective optimisation problem is formulated to contemporaneously take into account the flashover rate and the cost of the protection devices. The random nature of lightning events needs to be considered to find optimal protection. Traditional approaches typically use the Monte Carlo method to reproduce large series of lightning events that vary in location, current intensity, and current ramp rate. However, the high computational effort of the Monte Carlo approach makes it difficult to carry out the above analysis, especially when dealing with complex networks. Thus, in this paper, the Design of Experiments is proposed as the statistical tool to characterize lightning events. More specifically, full factorial design and Taguchi arrays are used which allow for significantly reducing the computational effort. Numerical applications on an actual distribution network located in Italy allowed a comparison of these methods to the Monte Carlo approach. The results evidenced the effectiveness of the proposed approach in terms of computational effort and accuracy of the analysis.