Objectives: To investigate the prevalence, gender influence, and relationships between burnout, depression and suicidal ideation within the last year among second, fourth and fifth-year dental students. Study Design: A cross-sectional study was carried out in 212 dental students enrolled in the second, fourth and fifth years at the School of Dentistry of Seville using the Maslach Burnout Inventory-Student Survey and the MBI-Human Services Survey, the “Patient Health Questionnaire-2”, and the “Questions about Suicidal Ideation and Attempted Suicide”. Results: The response rate among dental students was 80%. Burnout prevalence in dental students was higher in second and fourth years than in fifth year (p= 0.059 and p= 0.003, respectively). Depression prevalence in the fourth year approached significance (p= 0.051). Prevalence of suicidal ideation within the past year was higher, yet not reaching significance, in fourth year. No gender-related differences were found. A significant association was observed between burnout and depression, and between depression and suicidal ideation (p< 0.001), but no association was found between burnout and suicidal ideation. Conclusions: This study has brought our attention to the high prevalence of burnout and depression, and reported for the first time the prevalence of suicidal ideation among dental students in preclinical and clinical years.
Introduction. Digital impressions in implant dentistry rely on many variables, and their accuracy, particularly in complete edentulous patients, is not well understood. Aim. The purpose of this literature review was to determine which factors may influence the accuracy of digital impressions in implant dentistry. Emphasized attention was given to the design of the intra-oral scan body (ISB) and scanning techniques. Materials and methods. A Medline, PubMed and EBSCO Host databases search, complemented by a hand search, was performed in order to select relevant reports regarding the appliance of digital impressions in implant dentistry. The search subject included but was not limited to accuracy of digital impressions in implant dentistry, digital scanning techniques, the design and material of the ISBs, and the depth and angulation of the implant. The related titles and abstracts were screened, and the remaining articles that fulfilled the inclusion criteria were selected for full-text readings. Results. The literature search conducted for this review initially resulted in 108 articles, among which only 21 articles fulfilled the criteria for inclusion. Studies were evaluated according to five subjects: accuracy of digital impressions in implant dentistry; the design and material of the intra-oral scan bodies; scanning technique; the influence of implants depth/angulations on the digital impression and accuracy of different intra-oral scanner devices. Conclusions. The accuracy of digital impressions in implant dentistry depends on several aspects. The depth/angulation of the implant, the experience of the operator, the intra-oral scanner used, and environmental conditions may influence the accuracy of digital impressions in implant dentistry. However, it seems that ISBs’ design and material, as well as scanning technique, have a major impact on the trueness and precision of digital impressions in implant dentistry. Future research is suggested for the better understanding of this subject, focusing on the optimization of the ISB design and scanning protocols.
Gingivitis and periodontitis are chronic inflammatory diseases that affect the supporting tissues of the teeth. Although induced by the presence of bacterial biofilms, other factor, such as tobacco smoking, drugs, and various systemic diseases, are known to influence their pathogenesis. Diabetes mellitus and periodontal diseases correspond to inflammatory diseases that have pathogenic mechanisms in common, with the involvement of pro-inflammatory mediators. A bidirectional relationship between type 2 diabetes and periodontitis has been documented in several studies. Significantly less studies have focused on the association between periodontal disease and type 1 diabetes. The aim of the study is to analyze the association between periodontal status and type 1 diabetes mellitus. The “Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines” was used and registered at PROSPERO. The search strategy included electronic databases from 2012 to 2021 and was performed by two independent reviewers. According to our results, we found one article about the risk of periodontal diseases in type 1 diabetes mellitus subjects; four about glycemic control; two about oral hygiene; and eight about pro-inflammatory cytokines. Most of the studies confirm the association between type 1 diabetes mellitus and periodontal diseases. The prevalence and severity of PD was higher in DM1 patients when compared to healthy subjects.
Articles on the prevalence of peri-implant diseases showed that 90% of peri-implant tissues had some form of inflammatory response and a prevalence of peri-implantitis from 28% to 51% according to various publications. Objective: To provide an overview of how risk factors can be related with peri-implantitis. Methods: A retrospective longitudinal study including 555 implants placed in 132 patients was evaluated based on the presence of peri-implantitis following the criteria of Renvert et al. 2018. Results: In total, 21 patients (15.9%) suffered peri-implantitis (PPG) and 111 patients (84.1%) did not suffer peri-implantitis (NPG). The results reveal that smokers have a high incidence of peri-implantitis (72.7%) compared to non-smokers (27.3%) (p < 0.0005). Another variable with significant results (p < 0.01) was periodontitis: 50% PPG and 23.9% NPG suffered advanced periodontitis. Systemic diseases such as arterial hypertension, diabetes mellitus, osteoporosis, and cardiovascular diseases do not show a statistically significant influence on the incidence of peri-implantitis. Patients who did not attend their maintenance therapy appointment had an incidence of peri-implantitis of 61.4%, compared to 27.3% in those who attend (p < 0.0001). From the results obtained, we can conclude that relevant factors affect peri-implantitis, such as tobacco habits, moderate and severe periodontitis, and attendance in maintenance therapy.
The aim of this study was to evaluate the effects of different implant sites an under-preparation sequence associated with two different implant designs on implant primary stability measured by two parameters: insertion torque (IT) and implant stability quotient (ISQ). It used two different implants: one cylindrical as a control and another one with a tapered design. The implants were inserted in type III fresh humid bovine bone and four drilling sequences were used: one control, the one proposed by the implant company (P1), and three different undersized (P2, P3 and P4). P2 was the same as P1 without the cortical drill, P3 was without the last pilot drill and P4 was without both of them. The sample size was n = 40 for each of the eight groups. Final IT was measured with a torquemeter and the ISQ was measured with Penguin resonance frequency analysis. Results showed that both ISQ and IT have a tendency to increase as the preparation technique reduces the implant site diameter when compared with the standard preparation, P1. The preparations without cortical drill, P2 and P4, showed the best results when compared with the ones with a cortical drill. Tapered implants always showed higher or the same ISQ and IT values when compared with the cylindrical implants. Giving the limitations of this study, it can be concluded that reducing implant preparation can increase IT and ISQ values. Removing the cortical drill and the use of a tapered design implant are also effective methods of increasing primary implant stability.
The aim of this study was to find in the literature data on the relationship between implant surface roughness and implant stability achieved, from the time of placement to three months afterward, to help us to know what type of surface roughness is more favorable to guarantee implant stability and osseointegration. A systematic review was conducted in accordance with the PRISMA 2020 (Preferred Reporting Items for Systematic Review and Meta-analysis) statement, and the protocol was registered on the Open Science Framework. The specific inclusion and exclusion criteria were selected using the PICOS framework. The databases Medline (PubMed), Scopus, the Web of Science and The Cochrane Library were searched up to October 2023. The selection of studies and data extraction were conducted by two independent reviewers. The review included a total of 11 studies. A total of 1331 dental implant placements were identified. Two of the eleven selected studies were on humans in vivo, eight were on animals in vivo, and one was on animals in vitro. A statistically significant correlation between surface roughness and implant stability as measured by resonance frequency analysis (RFA) was not identified in ten of the eleven selected studies. It appears that there is no correlation between primary stability and the degree of implant roughness. However, there appears to be a correlation between the roughness of the implant and the degree of osseointegration, as indicated by bone-implant contact values. This correlation is more closely related to secondary stability. The great methodological variability makes it difficult to compare data and draw conclusions, so it would be desirable to agree on a common methodology to help draw appropriate conclusions from published studies.