Paulo António Ribeiro

Prof. Paulo António Ribeiro

Universidade Fernando Pessoa
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Simone MarquesSimone Marques
Simone Marques
Paulo António RibeiroPaulo António Ribeiro
Paulo António Ribeiro
CFCarlos Falcão
Carlos Falcão
Bernardo Ferreira de LemosBernardo Ferreira de Lemos
Bernardo Ferreira de Lemos
BRBlanca Ríos-Carrasco
Blanca Ríos-Carrasco
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
Introduction. Digital impressions in implant dentistry rely on many variables, and their accuracy, particularly in complete edentulous patients, is not well understood. Aim. The purpose of this literature review was to determine which factors may influence the accuracy of digital impressions in implant dentistry. Emphasized attention was given to the design of the intra-oral scan body (ISB) and scanning techniques. Materials and methods. A Medline, PubMed and EBSCO Host databases search, complemented by a hand search, was performed in order to select relevant reports regarding the appliance of digital impressions in implant dentistry. The search subject included but was not limited to accuracy of digital impressions in implant dentistry, digital scanning techniques, the design and material of the ISBs, and the depth and angulation of the implant. The related titles and abstracts were screened, and the remaining articles that fulfilled the inclusion criteria were selected for full-text readings. Results. The literature search conducted for this review initially resulted in 108 articles, among which only 21 articles fulfilled the criteria for inclusion. Studies were evaluated according to five subjects: accuracy of digital impressions in implant dentistry; the design and material of the intra-oral scan bodies; scanning technique; the influence of implants depth/angulations on the digital impression and accuracy of different intra-oral scanner devices. Conclusions. The accuracy of digital impressions in implant dentistry depends on several aspects. The depth/angulation of the implant, the experience of the operator, the intra-oral scanner used, and environmental conditions may influence the accuracy of digital impressions in implant dentistry. However, it seems that ISBs’ design and material, as well as scanning technique, have a major impact on the trueness and precision of digital impressions in implant dentistry. Future research is suggested for the better understanding of this subject, focusing on the optimization of the ISB design and scanning protocols.

Paulo António RibeiroPaulo António Ribeiro
Paulo António Ribeiro
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
CDCarmen María Díaz-Castro
Carmen María Díaz-Castro
José Vicente Ríos-SantosJosé Vicente Ríos-Santos
José Vicente Ríos-Santos
RPRoberto Padrós
Roberto Padrós
CFCarlos Falcão
Carlos Falcão
Purpose: The aim of this study was to compare the accuracy of digital dental impressions with the accuracy of impressions obtained via conventional techniques. Methods: Two different master models were created, one with parallel implants (model 1) and the other with non-parallel implants (model 2). These reference master models included 4 Klockner KL RP implants (Klockner Implant System SA, Barcelona, Spain), which were juxta-placed and equidistant in the intermentoneal region. In model 1 the implants were placed parallel to each other, whereas in model 2 the implants were placed such that there was a divergence angle of 15° between the more distal implants, and a convergence angle of 15° between the two central implants. A total of four types of impressions were obtained from model 1 (four groups, n = 10 each), including closed tray impressions with replacement abutments; open tray impression groups for dragging copings, without splinting; open tray impressions for ferrules; and impressions obtained using the 3MTM True Definition Scanner system. For model 2 three groups were created (three groups, n = 10 each), including closed tray impressions with replacement abutments; open tray impression for dragging copings, without splinting; and impressions obtained using the 3MTM True Definition Scanner system. The master models and the models obtained using conventional methods were digitalized in order to compare them via an extraoral high-resolution scanner (Imetric IScan D104i, Porretruy, Switzerland). The STL (Stereo Lithography (format for transferring 3 dimensional shape information)) digital values were loaded into reverse-engineering software and superimposed with their respective STL master models in order to evaluate deviations in three dimensions. We then analyzed the squares of the deviations in the three axes and evaluated the median and the sum of the deviation square. Statistical analysis was performed using the IBM Corp. Released 2016. IBM SPSS Statistics for Windows, Version 24.0. Armonk, NY: IBM Corp. The normality of the distributions was analyzed according to a Kolmogorov-Smirnov test. The median comparison was performed using the differences between the medians, analyzed using non-parametric Kruskal-Wallis and Mann-Whitney tests with a significance level of p < 0.05. Results: For model 1, the deviations of the digital impressions were smaller than those associated with the conventional techniques. The sum value in group D was 1,068,292, which was significantly lower than those of groups A, B, and C, which were shown to be 2,114,342, 2,165,491, and 1,265,918, respectively. This improvement was not observed when using model 2, however, where the conventional techniques yielded similar results. Group F simultaneously presented the lowest total square sum of the three deviations (1,257,835), indicating a significantly higher accuracy for this group in model 2, while the sum values were 1,660,975 and 1,489,328 for groups E and G, respectively. Conclusion: Digital impressions of full-arch models were able to achieve the accuracy of conventional impressions in an in vitro model. Nevertheless, further in vivo studies are needed to validate these in vitro results.

15 August 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
Paulo António RibeiroPaulo António Ribeiro
Paulo António Ribeiro
CDCarmen María Díaz-Castro
Carmen María Díaz-Castro
BRBlanca Ríos-Carrasco
Blanca Ríos-Carrasco
José Vicente Ríos-SantosJosé Vicente Ríos-Santos
José Vicente Ríos-Santos
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
Photogrammetry (PG) appeared as an alternative for multiple implant impressions. Stereo-photogrammetry is a more sophisticated alternative to PG, which estimates the 3D coordinates of the points of an object, making the process quicker and more precise. A search in PubMed MEDLINE, PMC, and Google Scholar was conducted to find systematic reviews published in the last 10 years. The PICdental® camera (IDITEC NORTH WEST, SL; Torrelodones, Spain) is a stereocamera that records implant positions in the mouth by means of photogrammetry with the objective of registering and obtaining a viable, reliable, and direct digital impression of the positions of the multiple implants. The use of photogrammetry via PiCdental® camera as an alternative to digital impression for multiple implants is an easy and trustworthy technique that permits an adequate fit without prosthetic complications.

Joana Meneses MartinsJoana Meneses Martins
Joana Meneses Martins
LGliliana Gavinha-Costa
liliana Gavinha-Costa
Ana Lidia Furtado Gamonal de CarvalhoAna Lidia Furtado Gamonal de Carvalho
Ana Lidia Furtado Gamonal de Carvalho
MMMaria-Conceição Manso
Maria-Conceição Manso
SGSandra Gavinha
Sandra Gavinha
Paulo António RibeiroPaulo António Ribeiro
Paulo António Ribeiro
Background: The objective was to determine if asymmetric facial features, nasal and chin deviations, affect the perception of attractiveness of a dental midline angulation, and if it is consistent among both dentists and laypeople. It was also analyzed if factors, such as the sex, age group of the participants and the dentist’s area of operation are relevant in their assessment. Methods: A cross-sectional study, approved by the Ethics Committee of Fernando Pessoa University. From a symmetrical facial model (SFM) image, a natural-looking asymmetrical face was created. Based on this asymmetric facial model six images were created, with different directions and degrees of inclination of the dental midline. In total, 236 laypersons and 242 dentists completed the online questionnaire where they rated the self-perception of attractiveness of the eight images (VAS scale from 0 to 10). Non-parametric comparisons (IBM© SPSS Statistics vs. 27.0, p < 0.05). Results: The results showed a significant difference in the perception of attractiveness between laypeople and dentists. This finding was consistent regarding every image, except for the SFM. The factors, sex of the people participating and dentist’s area of operation, seemed only to contribute to a significant difference in the perception when it came to the SFM. The perceived attractiveness of the images, for dentists and laypersons, did not differ by age group of the participant, apart from images 6 and 8. Conclusions: Dentists are more rigorous about dental midline inclinations than laypersons. The perception of attractiveness was affected by the age group and sex of the participants and the dentist’s area of operation.

24 August 2022 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
SMSimone Marques
Simone Marques
Paulo António RibeiroPaulo António Ribeiro
Paulo António Ribeiro
CGCatarina Gama
Catarina Gama
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
This article describes a digital workflow for ceramic veneer preparation using computer-aided design and computer-aided manufacturing technology. A digital waxing was planned on the exocad software program to reestablish esthetic and functional parameters. Then, the digital guides for veneer preparation were designed by using the Meshmixer design software program to control the tooth structure removed during preparation to the minimal thickness necessary for the definitive restorations. The digital guides were printed in an additively manufactured clear resin and used in the preparation appointment, allowing a more conservative and controlled preparation.

Ana Lidia Furtado Gamonal de CarvalhoAna Lidia Furtado Gamonal de Carvalho
Ana Lidia Furtado Gamonal de Carvalho
LGliliana Gavinha-Costa
liliana Gavinha-Costa
Joana Meneses MartinsJoana Meneses Martins
Joana Meneses Martins
MMMaria-Conceição Manso
Maria-Conceição Manso
SGSandra Gavinha
Sandra Gavinha
Paulo António RibeiroPaulo António Ribeiro
Paulo António Ribeiro
The present study had a convenience sample with 236 laypeople and 242 dentists who completed an online questionnaire to choose the most attractive image among six pairs for comparison. Control image: symmetric (parallelism between occlusal plane (OP), commissural line (CL), and interpupillary line (IL)). Change of Control, obtaining three images with a 3-degree inclination of the labial commissures. Image A: OP parallel to IL; Image B: OP parallel to CL; Image C: OP at 1.5 degree mean angulation between IL and CL. Non-parametric comparison (IBM© SPSS Statistics vs. 27.0, p < 0.05). The “Dentists” group’s decreasing order of preference (attractiveness) of the images is: Control > A > C > B (p < 0.05). In the “Lay” group, it is: Control > A > (C not ≠ B). Dentists significantly prefer more the Control and Image A than laypeople (p < 0.001). Sex (single exception in laypeople), age, and dentist’s area of activity did not interfere in the perception of attractiveness. Dentists and laypeople preferred the Control when compared to images with CL canted. In the existence of CL inclination, the preference of the groups was the IL as a reference for OP orientation, with the mean angulation or coincident with the CL being considered less aesthetic.