Stefan Zeisler

Stefan Zeisler


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2013 in Journal of Radioanalytical and Nuclear Chemistry
Verified
Journal Article
Closed access
PDF file
VHV. Hanemaayer
V. Hanemaayer
FBFrancois Benard
Francois Benard
KBK. R. Buckley
K. R. Buckley
JKJ. Klug
J. Klug
MKM. Kovacs
M. Kovacs
SZStefan Zeisler
Stefan Zeisler

1 February 2019 in Instruments
Verified
Journal Article
Open access
PDF file
SZStefan Zeisler
Stefan Zeisler
ALAlan Limoges
Alan Limoges
JKJoel Kumlin
Joel Kumlin
JSJonathan Siikanen
Jonathan Siikanen
CHCornelia Hoehr
Cornelia Hoehr
Gallium-68 is a popular radioisotope for positron emission tomography. To make gallium-68 more accessible, we developed a new solid target for medical cyclotrons. Fused zinc targets promise a new, efficient, and reliable technique without the downsides of other commonly used time-consuming methods for solid target fabrication, such as electroplating and sputtering. We manufactured targets by fusing small pressed zinc pellets into a recess in aluminum backings. Using a simple hotplate, the fusing could be accomplished in less than two minutes. Subsequently, the targets were cooled, polished, and used successfully for test irradiations at Ep = 12.8 MeV and up to 20 µA proton current.

3 July 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MBMichael Bakaic
Michael Bakaic
MHMatthew Hanna
Matthew Hanna
CHCyril Hnatovsky
Cyril Hnatovsky
DGDan Grobnic
Dan Grobnic
SMStephen Mihailov
Stephen Mihailov
CHCornelia Hoehr
Cornelia Hoehr
A Bragg grating inscribed into an inorganic optical fiber was tested in proton and neutron fields up to doses of 472 Gy. Observation showed that radiation had no effect on the performance of the Fiber Bragg Grating (FBG) used as a gauge measuring temperature and pressure. The FBG sensor was subsequently employed to measure the temperature and pressure inside a liquid isotope production target for nuclear medicine. The fiber Bragg grating measured the temperature and pressure of a water target as a 12 MeV proton beam impinged on it in real time and was tested with beam currents of up to 20 µA.

29 June 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CHCornelia Hoehr
Cornelia Hoehr
MHMatthew Hanna
Matthew Hanna
SZStefan Zeisler
Stefan Zeisler
CPCrystal Penner
Crystal Penner
MSMatthew Stokely
Matthew Stokely
MDMorgan Dehnel
Morgan Dehnel
Many medical isotopes can be produced on a small cyclotron. The alignment and profiles of low-energy proton beams from cyclotrons used for medical radioisotope production, such as the TR13 cyclotron at TRIUMF, Canada, cannot be directly quantified during dose delivery with simultaneous constant feedback and sharp spatial resolutions. Doped silica fibers are a potential solution that has been tested at TRIUMF. To measure the effects of irradiation inside an isotope production target, we attached fibers to the outside of an 18O gas target and measured the light output during irradiation. Different dopants, fiber diameters, and target materials were investigated. It was found that 200 µm diameter Ce- and B-doped fibers produce signals linearly proportional to the beam current. This only deviated when the target was moved such that the beam was steered into the target wall, increasing the production of prompt radiation and causing the beam current to decrease but the fiber signal to increase. With the technique described here, the beam can be monitored on the target, including its steering and its overall alignment with the target.

12 February 2019 in Instruments
Verified
Journal Article
Open access
PDF file
SZStefan Zeisler
Stefan Zeisler
BCBenjamin Clarke
Benjamin Clarke
JKJoel Kumlin
Joel Kumlin
BHBrian Hook
Brian Hook
SVSam Varah
Sam Varah
CHCornelia Hoehr
Cornelia Hoehr
A new solid target system for the TRIUMF TR13 cyclotron that can accommodate target discs with a 1-2-mm thickness and a 28-mm diameter has been developed. The target system design is based on a modified clamping mechanism of a KF-40 vacuum connector, and comprises an easy and quick ejection mechanism for the target plate. The new quick-release target system decreases the retrieval time of the irradiated target to less than 1 minute and is expected to reduce the radiation burden to operating staff by a factor of ~10.

31 August 2013 in Journal of Radioanalytical and Nuclear Chemistry
Verified
Journal Article
Closed access
PDF file
VJVinder Jaggi
Vinder Jaggi
SOSteven Olson
Steven Olson
BKBhupender Kumar
Bhupender Kumar
SZStefan Zeisler
Stefan Zeisler