Developing a computational method for recognizing preterm delivery is important for timely diagnosis and treatment of preterm delivery. The main aim of this study was to evaluate electrohysterogram (EHG) signals recorded at different gestational weeks for recognizing the preterm delivery using random forest (RF). EHG signals from 300 pregnant women were divided into two groups depending on when the signals were recorded: i) preterm and term delivery with EHG recorded before the 26th week of gestation (denoted by PE and TE group), and ii) preterm and term delivery with EHG recorded during or after the 26th week of gestation (denoted by PL and TL group). 31 linear features and nonlinear features were derived from each EHG signal, and then compared comprehensively within PE and TE group, and PL and TL group. After employing the adaptive synthetic sampling approach and six-fold cross-validation, the accuracy (ACC), sensitivity, specificity and area under the curve (AUC) were applied to evaluate RF classification. For PL and TL group, RF achieved the ACC of 0.93, sensitivity of 0.89, specificity of 0.97, and AUC of 0.80. Similarly, their corresponding values were 0.92, 0.88, 0.96 and 0.88 for PE and TE group, indicating that RF could be used to recognize preterm delivery effectively with EHG signals recorded before the 26th week of gestation.
This study evaluates the progression of visual fatigue induced by visual display terminal (VDT) using automatically detected blink features. A total of 23 subjects were recruited to participate in a VDT task, during which they were required to watch a 120-min video on a laptop and answer a questionnaire every 30 min. Face video recordings were captured by a camera. The blinking and incomplete blinking images were recognized by automatic detection of the parameters of the eyes. Then, the blink features were extracted including blink number (BN), mean blink interval (Mean_BI), mean blink duration (Mean_BD), group blink number (GBN), mean group blink interval (Mean_GBI), incomplete blink number (IBN), and mean incomplete blink interval (Mean_IBI). The results showed that BN and GBN increased significantly, and that Mean_BI and Mean_GBI decreased significantly over time. Mean_BD and Mean_IBI increased and IBN decreased significantly only in the last 30 min. The blink features automatically detected in this study can be used to evaluate the progression of visual fatigue.
Arterial pulse waveform analysis has been widely used to reflect physiological changes in the cardiovascular system. This study aimed to comprehensively investigate the changes of waveform characteristics of both photoplethysmographic (PPG) and radial pulses with gestational age during normal pregnancy. PPG and radial pulses were simultaneously recorded from 130 healthy pregnant women at seven gestational time points. After normalizing the arterial pulse waveforms, the abscissa of notch point, the total pulse area and the reflection index were extracted and compared between different measurement points and between the PPG and radial pulses using post-hoc multiple comparisons with Bonferrioni correction. The results showed that the effect of gestational age on all the three waveform characteristics was significant (all p < 0.001) after adjusting for maternal age, heart rate and blood pressures. All the three waveform characteristics demonstrated similar changing trends with gestational age, and they were all significantly different between the measurements from gestational week 12–15 and the others (all p < 0.05, except for the PPG total pulse area between the first and second measurement points). In conclusion, this study has comprehensively quantified similar changes of both PPG and radial pulse waveform characteristics with gestational age.
Alcohol misuse is associated with altered punishment and reward processing. Here, we investigated neural network responses to reward and punishment and the molecular profiles of the connectivity features predicting alcohol use severity in young adults. We curated the Human Connectome Project data and employed connectome-based predictive modeling (CPM) to examine how functional connectivity (FC) features during wins and losses are associated with alcohol use severity, quantified by Semi-Structured Assessment for the Genetics of Alcoholism, in 981 young adults. We combined the CPM findings and the JuSpace toolbox to characterize the molecular profiles of the network connectivity features of alcohol use severity. The connectomics predicting alcohol use severity appeared specific, comprising less than 0.12% of all features, including medial frontal, motor/sensory, and cerebellum/brainstem networks during punishment processing and medial frontal, fronto-parietal, and motor/sensory networks during reward processing. Spatial correlation analyses showed that these networks were associated predominantly with serotonergic and GABAa signaling. To conclude, a distinct pattern of network connectivity predicted alcohol use severity in young adult drinkers. These “neural fingerprints” elucidate how alcohol misuse impacts the brain and provide evidence of new targets for future intervention.
1 March 2018 in The Journal of Physiological Sciences
It is physiologically important to understand the arterial pulse waveform characteristics change during exercise and recovery. However, there is a lack of a comprehensive investigation. This study aimed to provide scientific evidence on the arterial pulse characteristics change during exercise and recovery. Sixty-five healthy subjects were studied. The exercise loads were gradually increased from 0 to 125 W for female subjects and to 150 W for male subjects. Radial pulses were digitally recorded during exercise and 4-min recovery. Four parameters were extracted from the raw arterial pulse waveform, including the pulse amplitude, width, pulse peak and dicrotic notch time. Five parameters were extracted from the normalized radial pulse waveform, including the pulse peak and dicrotic notch position, pulse Area, Area1 and Area2 separated by notch point. With increasing loads during exercise, the raw pulse amplitude increased significantly with decreased pulse period, reduced peak and notch time. From the normalized pulses, the pulse Area, pulse Area1 and Area2 decreased, respectively, from 38 ± 4, 61 ± 5 and 23 ± 5 at rest to 34 ± 4, 52 ± 6 and 13 ± 5 at 150-W exercise load. During recovery, an opposite trend was observed. This study quantitatively demonstrated significant changes of radial pulse characteristics during different exercise loads and recovery phases.
Electrohysterogram (EHG) is a promising method for noninvasive monitoring of uterine electrical activity. The main purpose of this study was to characterize the multichannel EHG signals to distinguish between term delivery and preterm birth, as well as deliveries within and beyond 24 h. A total of 219 pregnant women were grouped in two ways: (1) term delivery (TD), threatened preterm labor (TPL) with the outcome of preterm birth (TPL_PB), and TPL with the outcome of term delivery (TPL_TD); (2) EHG recording time to delivery (TTD) ≤ 24 h and TTD > 24 h. Three bipolar EHG signals were analyzed for the 30 min recording. Six EHG features between multiple channels, including multivariate sample entropy, mutual information, correlation coefficient, coherence, direct partial Granger causality, and direct transfer entropy, were extracted to characterize the coupling and information flow between channels. Significant differences were found for these six features between TPL and TD, and between TTD ≤ 24 h and TTD > 24 h. No significant difference was found between TPL_PB and TPL_TD. The results indicated that EHG signals of TD were more regular and synchronized than TPL, and stronger coupling between multichannel EHG signals was exhibited as delivery approaches. In addition, EHG signals propagate downward for the majority of pregnant women regardless of different labors. In conclusion, the coupling and propagation features extracted from multichannel EHG signals could be used to differentiate term delivery and preterm birth and may predict delivery within and beyond 24 h.