Dongmei Hao

Prof. Dr. Dongmei Hao

Beijing University of Technology, Beijing 100124
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Biocybernetics and Biomedical Engineering
Verified
Journal Article
Open access
JPJin Peng
Jin Peng
DHDongmei Hao
Dongmei Hao
LYLin Yang
Lin Yang
MDMengqing Du
Mengqing Du
XSXiaoxiao Song
Xiaoxiao Song
DZDingchang Zheng
Dingchang Zheng
Developing a computational method for recognizing preterm delivery is important for timely diagnosis and treatment of preterm delivery. The main aim of this study was to evaluate electrohysterogram (EHG) signals recorded at different gestational weeks for recognizing the preterm delivery using random forest (RF). EHG signals from 300 pregnant women were divided into two groups depending on when the signals were recorded: i) preterm and term delivery with EHG recorded before the 26th week of gestation (denoted by PE and TE group), and ii) preterm and term delivery with EHG recorded during or after the 26th week of gestation (denoted by PL and TL group). 31 linear features and nonlinear features were derived from each EHG signal, and then compared comprehensively within PE and TE group, and PL and TL group. After employing the adaptive synthetic sampling approach and six-fold cross-validation, the accuracy (ACC), sensitivity, specificity and area under the curve (AUC) were applied to evaluate RF classification. For PL and TL group, RF achieved the ACC of 0.93, sensitivity of 0.89, specificity of 0.97, and AUC of 0.80. Similarly, their corresponding values were 0.92, 0.88, 0.96 and 0.88 for PE and TE group, indicating that RF could be used to recognize preterm delivery effectively with EHG signals recorded before the 26th week of gestation.

1 October 2019 in Computers in Biology and Medicine
Verified
Journal Article
Open access
DHDongmei Hao
Dongmei Hao
JPJin Peng
Jin Peng
YWYing Wang
Ying Wang
JLJuntao Liu
Juntao Liu
XZXiya Zhou
Xiya Zhou
DZDingchang Zheng
Dingchang Zheng
Uterine contraction (UC) activity is commonly used to monitor the approach of labour and delivery. Electrohysterograms (EHGs) have recently been used to monitor UC and distinguish between efficient and inefficient contractions. In this study, we aimed to identify UC in EHG signals using a convolutional neural network (CNN). An open-access database (Icelandic 16-electrode EHG database from 45 pregnant women with 122 recordings, DB1) was used to develop a CNN model, and 14000 segments with a length of 45 s (7000 from UCs and 7000 from non-UCs, which were determined with reference to the simultaneously recorded tocography signals) were manually extracted from the 122 EHG recordings. Five-fold cross-validation was applied to evaluate the ability of the CNN to identify UC based on its sensitivity (SE), specificity (SP), accuracy (ACC), and area under the receiver operating characteristic curve (AUC). The CNN model developed using DB1 was then applied to an independent clinical database (DB2) to further test its generalisation for recognizing UCs. The EHG signals in DB2 were recorded from 20 pregnant women using our multi-channel system, and 308 segments (154 from UCs and 154 from non-UCs) were extracted. The CNN model from five-fold cross-validation achieved average SE, SP, ACC, and AUC of 0.87, 0.98, 0.93, and 0.92 for DB1, and 0.88, 0.97, 0.93, and 0.87 for DB2, respectively. In summary, we demonstrated that CNN could effectively identify UCs using EHG signals and could be used as a tool for monitoring maternal and foetal health.

24 February 2012 in Neurological Sciences
Verified
Journal Article
Closed access
PDF file
DHDongmei Hao
Dongmei Hao
LYLei Yang
Lei Yang
SCSu Chen
Su Chen
JTJun Tong
Jun Tong
YTYonghao Tian
Yonghao Tian
YZYanjun Zeng
Yanjun Zeng

10 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Félix Nieto-del-AmorFélix Nieto-del-Amor
Félix Nieto-del-Amor
RBRaja Beskhani
Raja Beskhani
YYYiyao Ye-Lin
Yiyao Ye-Lin
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
ADAlba Díaz
Alba Díaz
GPGema Prats-Boluda
Gema Prats-Boluda
One of the remaining challenges for the scientific-technical community is predicting preterm births, for which electrohysterography (EHG) has emerged as a highly sensitive prediction technique. Sample and fuzzy entropy have been used to characterize EHG signals, although they require optimizing many internal parameters. Both bubble entropy, which only requires one internal parameter, and dispersion entropy, which can detect any changes in frequency and amplitude, have been proposed to characterize biomedical signals. In this work, we attempted to determine the clinical value of these entropy measures for predicting preterm birth by analyzing their discriminatory capacity as an individual feature and their complementarity to other EHG characteristics by developing six prediction models using obstetrical data, linear and non-linear EHG features, and linear discriminant analysis using a genetic algorithm to select the features. Both dispersion and bubble entropy better discriminated between the preterm and term groups than sample, spectral, and fuzzy entropy. Entropy metrics provided complementary information to linear features, and indeed, the improvement in model performance by including other non-linear features was negligible. The best model performance obtained an F1-score of 90.1 ± 2% for testing the dataset. This model can easily be adapted to real-time applications, thereby contributing to the transferability of the EHG technique to clinical practice.

7 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Félix Nieto-del-AmorFélix Nieto-del-Amor
Félix Nieto-del-Amor
GPGema Prats-Boluda
Gema Prats-Boluda
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
ADAlba Díaz
Alba Díaz
VAVicente José Diago Almela
Vicente José Diago Almela
YYYiyao Ye-Lin
Yiyao Ye-Lin
Due to its high sensitivity, electrohysterography (EHG) has emerged as an alternative technique for predicting preterm labor. The main obstacle in designing preterm labor prediction models is the inherent preterm/term imbalance ratio, which can give rise to relatively low performance. Numerous studies obtained promising preterm labor prediction results using the synthetic minority oversampling technique. However, these studies generally overestimate mathematical models’ real generalization capacity by generating synthetic data before splitting the dataset, leaking information between the training and testing partitions and thus reducing the complexity of the classification task. In this work, we analyzed the effect of combining feature selection and resampling methods to overcome the class imbalance problem for predicting preterm labor by EHG. We assessed undersampling, oversampling, and hybrid methods applied to the training and validation dataset during feature selection by genetic algorithm, and analyzed the resampling effect on training data after obtaining the optimized feature subset. The best strategy consisted of undersampling the majority class of the validation dataset to 1:1 during feature selection, without subsequent resampling of the training data, achieving an AUC of 94.5 ± 4.6%, average precision of 84.5 ± 11.7%, maximum F1-score of 79.6 ± 13.8%, and recall of 89.8 ± 12.1%. Our results outperformed the techniques currently used in clinical practice, suggesting the EHG could be used to predict preterm labor in clinics.

21 January 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
XSXiaoxiao Song
Xiaoxiao Song
XQXiangyun Qiao
Xiangyun Qiao
DHDongmei Hao
Dongmei Hao
LYLin Yang
Lin Yang
XZXiya Zhou
Xiya Zhou
DZDingchang Zheng
Dingchang Zheng
Uterine contraction (UC) is an essential clinical indicator in the progress of labour and delivery. Electrohysterogram (EHG) signals recorded on the abdomen of pregnant women reflect the uterine electrical activity. This study proposes a novel algorithm for automatic recognition of UCs with EHG signals to improve the accuracy of detecting UCs. EHG signals by electrodes, the tension of the abdominal wall by tocodynamometry (TOCO) and maternal perception were recorded simultaneously in 54 pregnant women. The zero-crossing rate (ZCR) of the EHG signal and its power were calculated to modulate the raw EHG signal and highlight the EHG bursts. Then the envelope was extracted from the modulated EHG for UC recognition. Besides, UC was also detected by the conventional TOCO signal. Taking maternal perception as a reference, the UCs recognized by EHG and TOCO were evaluated with the sensitivity, positive predictive value (PPV), and UC parameters. The results show that the sensitivity and PPV are 87.8% and 93.18% for EHG, and 84.04% and 90.89% for TOCO. EHG detected a larger number of UCs than TOCO, which is closer to maternal perception. The duration and frequency of UC obtained from EHG and TOCO were not significantly different (p > 0.05). In conclusion, the proposed UC recognition algorithm has high accuracy and simple calculation which could be used for real-time analysis of EHG signals and long-term monitoring of UCs.