Tim Wittmann

Mr. Tim Wittmann

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
TWTim Wittmann
Tim Wittmann
SLSebastian Lück
Sebastian Lück
CBChristoph Bode
Christoph Bode
JFJens Friedrichs
Jens Friedrichs
Radial turbines used in automotive fuel cell turbochargers operate with humid air. The gas expansion in the turbine causes droplets to form, which then grow through condensation. The associated release of latent heat and decrease in the gaseous mass flow strongly influence the thermodynamics of the turbine. This study aims to investigate these phenomena. For this purpose, the classical nucleation theory and Young’s growth law are integrated into a Euler–Lagrange approach. The main advantages of this approach are the calculation of individual droplet trajectories and a full resolution of the droplet spectrum. The results indicate an onset of nucleation at the blade tip and in the tip gap, followed by nucleation over the entire blade span, depending on the humidity at the turbine inlet. With a saturated turbine inflow, condensation causes the outlet temperature to rise to almost the same level as at the inlet. In addition, condensation losses reduce the efficiency and the latent heat released by condensation leads to significant thermal throttling.

22 February 2021 in Journal of Engineering for Gas Turbines and Power
Verified
Journal Article
Closed access
PDF file
TWTim Wittmann
Tim Wittmann
CBChristoph Bode
Christoph Bode
JFJens Friedrichs
Jens Friedrichs
This study investigates the applicability of an Euler–Lagrange approach for the calculation of nucleation and condensation of steam flows. Supersonic nozzles are used as generic validation cases, as their high expansion rates replicate the flow conditions in real turbines. Experimental and numerical validation data for these nozzles are provided by the International Wet Steam Modeling Project of Starzmann et al. (2018, “Results of the International Wet Steam Modeling Project,” Proc. Inst. Mech. Eng. A, 232(5), pp. 550–570). In contrast to most participants of that project, an Euler–Lagrange approach is utilized for this study. Therefore, the classical nucleation theory with corrections and different droplet growth laws is incorporated into the discrete phase model of ansysfluent. Suggestions for an efficient implementation are presented. The Euler–Lagrange results show a good agreement with the experimental and numerical validation data. The sensitivities of the Euler–Lagrange approach to modeling parameters are analyzed. Finally, an optimal parameter set for the calculation of nucleation and condensation is proposed.

13 January 2022 in Machines
Verified
Journal Article
Open access
PDF file
SLSebastian Lück
Sebastian Lück
TWTim Wittmann
Tim Wittmann
JGJan Goeing
Jan Goeing
CBChristoph Bode
Christoph Bode
JFJens Friedrichs
Jens Friedrichs
A mobile fuel cell systems power output can be increased by pressure amplification using an electric turbocharger. These devices are subject to frequent transient manoeuvres due to a multitude of load changes during the mission in automotive applications. In this paper, the authors describe a simulation approach for an electric turbocharger, considering the impact of moist air and condensation within the cathode gas supply system. Therefore, two simulation approaches are used: an iterative simulation method and one based on a set of ordinary differential equations. Additional information is included from turbine performance maps taking into account condensation using Euler–Lagrange CFD simulations, which are presented. The iterative calculation approach is well suited to show the impact of condensation and moist air on the steady state thermodynamic cycle and yields a significant shift of the steady state operating line towards the surge line. It is shown that a substantial risk of surge occurs during transient deceleration manoeuvres triggered by a load step.

7 June 2021
Verified
Conference Paper
Closed access
PDF file
TWTim Wittmann
Tim Wittmann
SLSebastian Lück
Sebastian Lück
THTim Hertwig
Tim Hertwig
CBChristoph Bode
Christoph Bode
JFJens Friedrichs
Jens Friedrichs
Exhaust gas of an automotive fuel cell is enriched with water vapour and has a pressure potential which can be utilized by a turbine. The gas expansion in the turbine leads to droplet nucleation and condensation. This results in a release of latent heat and a decrease of the gaseous mass flow which has a considerable influence on the turbine performance. This study aims to numerically investigate the influence of these phenomena on the performance map of the radial turbine of an automotive fuel cell turbocharger. For this purpose, the classical nucleation theory and Young’s droplet growth law are integrated into an Euler-Lagrange approach. The results show an almost linear relation between the pressure ratio and the condensation while the specific aerodynamics of an operating point has only a minor influence. At 80 % relative humidity of the inflow, the investigated turbine showed condensation above a total-to-static pressure ratio of 1.8. Condensation leads to thermal throttling of the turbine and to a temperature increase of the rotor outflow of up to 50 K. Increasing humidity of the inflow increases the power output, but condensation losses reduce the efficiency.

10 November 2022 in Machines
Verified
Journal Article
Open access
PDF file
TWTim Wittmann
Tim Wittmann
SLSebastian Lück
Sebastian Lück
CBChristoph Bode
Christoph Bode
JFJens Friedrichs
Jens Friedrichs
The air-management system of a proton exchange membrane fuel cell (PEMFC) is responsible for supplying the fuel cell stack with ambient air at appropriate conditions. The compressor of the air-management system can be partly driven by utilizing the fuel cell exhaust gas in a turbine. The fuel cell exhaust is partially or fully saturated with water vapor. When the exhaust gas is expanded in the turbine, supersaturation occurs. This leads to the nucleation of droplets and their subsequent growth by condensation. This study provides an overview and understanding of the various phenomena caused by condensation and liquid water in the turbine of a PEMFC air-management system. The basis for this work is previously published numerical simulations that focused on individual aspects of the above phenomena. The present work revisits these results and puts them in context to provide a comprehensive understanding. Important phenomena are the effects of condensation on turbine performance through phase change losses, release of latent heat and thermal throttling. In addition, the released latent heat offers a power potential for downstream turbine stages. Through these effects, condensation can also impact the entire air-management system. However, condensation may occur unevenly, causing a circumferential asymmetry of the turbine outflow. Liquid water in the turbine can lead to droplet erosion, corrosion, and water-induced damage. In summary, it is essential to consider condensation and liquid water when developing turbines for PEMFC air-management systems.

31 October 2024 in Energies
Verified
Journal Article
Open access
PDF file
Mirosław MajkutMirosław Majkut
Mirosław Majkut
Sławomir DykasSławomir Dykas
Sławomir Dykas
KSKrystian Smołka
Krystian Smołka
TWTim Wittmann
Tim Wittmann
AKAxel Kuhlmann
Axel Kuhlmann
FTFlorian Thorey
Florian Thorey
Atmospheric air, being also a moist gas, is present as a working medium in various areas of technology, including the areas of airframe aerodynamics and turbomachinery. Issues related to the condensation of water vapor contained in atmospheric air have been intensively studied analytically, experimentally and numerically since the 1950s. An effort is made in this paper to present new, unique and complementary results of the experimental testing of moist air expansion in the de Laval nozzle. The results of the measurements, apart from the static pressure distribution on the nozzle wall and the images obtained using the Schlieren technique, additionally contain information regarding the quantity and quality of the condensate formed due to spontaneous condensation at the transition from the subsonic to the supersonic flow in the nozzle. The liquid phase was identified using the light extinction method (LEM). The experiments were performed for three geometries of convergent–divergent nozzles with different expansion rates of 3000, 2500 and 2000 s−1. It is shown that as the expansion rate increases, the phenomenon of water vapor spontaneous condensation appears closer to the critical cross-section of the nozzle. A study was performed of the impact of the air relative humidity and pollution on the process of condensation of the water vapor contained in the air. As indicated by the results, both these parameters have a significant effect on the flow field and the pressure distribution in the nozzle. The results of the experimental analyses show that in the case of the atmospheric air flow, in addition to the pressure, temperature and velocity, other parameters must also be taken into account as boundary parameters for possible numerical analyses. Omitting information about the air humidity and pollution can lead to incorrect results in numerical simulations of transonic flows of atmospheric air. The presented results of the measurements of the moist air transonic flow field are original and fill the research gap in the field of experimental studies on the phenomenon of water vapor spontaneous condensation.