The overall efficiency and operational behavior of aircraft engines are influenced by the surface finish of the airfoils. During operation, the surface roughness significantly increases due to erosion and deposition processes. The aim of this study is to analyze the influence of roughness on the aerodynamics of the low-pressure turbine of a mid-sized high bypass turbofan. In order to gain a better insight into the operational roughness structures, a sample of new, used, cleaned and reworked turbine blades and vanes are measured using the confocal laser scanning microscopy technique. The measurement results show local inhomogeneities. The roughness distributions measured are then converted into their equivalent sand grain roughness $k_{s,eq} $ to permit an evaluation of the impact on aerodynamic losses. The numerical study is performed using the CFD-solver TRACE which was validated before with existing data from Rig experiments. The service-induced roughness structures cause an efficiency drop in the low pressure turbine of $\eta_T = -0.16\%$ compared to new parts. A gas path analysis showed that this results in an increased fuel flow of $\Delta \dot m_f = +0.06\%$ and an exhaust gas temperature rise of $\Delta EGT = +1.2 K $ for fixed engine pressure ratio which is equivalent to roughly 4 percent of the typical EGT margin of a fully refurbished engine. This result stresses the importance of roughness induced loss in low pressure turbines.
Radial turbines used in automotive fuel cell turbochargers operate with humid air. The gas expansion in the turbine causes droplets to form, which then grow through condensation. The associated release of latent heat and decrease in the gaseous mass flow strongly influence the thermodynamics of the turbine. This study aims to investigate these phenomena. For this purpose, the classical nucleation theory and Young’s growth law are integrated into a Euler–Lagrange approach. The main advantages of this approach are the calculation of individual droplet trajectories and a full resolution of the droplet spectrum. The results indicate an onset of nucleation at the blade tip and in the tip gap, followed by nucleation over the entire blade span, depending on the humidity at the turbine inlet. With a saturated turbine inflow, condensation causes the outlet temperature to rise to almost the same level as at the inlet. In addition, condensation losses reduce the efficiency and the latent heat released by condensation leads to significant thermal throttling.
High aspect ratio aircraft have a significantly reduced induced drag, but have only limited installation space for control surfaces near the wingtip. This paper describes a multidisciplinary design methodology for a morphing aileron that is based on pressure-actuated cellular structures (PACS). The focus of this work is on the transient dynamic system behavior of the multi-functional aileron. Decisive design aspects are the actuation speed, the resistance against external loads, and constraints preparing for a future wind tunnel test. The structural stiffness under varying aerodynamic loads is examined while using a reduced-order truss model and a high-fidelity finite element analysis. The simulations of the internal flow investigate the transient pressurization process that limits the dynamic actuator response. The authors present a reduced-order model based on the Pseudo Bond Graph methodology enabling time-efficient flow simulation and compare the results to computational fluid dynamic simulations. The findings of this work demonstrate high structural resistance against external forces and the feasibility of high actuation speeds over the entire operating envelope. Future research will incorporate the fluid–structure interaction and the assessment of load alleviation capability.
A mobile fuel cell systems power output can be increased by pressure amplification using an electric turbocharger. These devices are subject to frequent transient manoeuvres due to a multitude of load changes during the mission in automotive applications. In this paper, the authors describe a simulation approach for an electric turbocharger, considering the impact of moist air and condensation within the cathode gas supply system. Therefore, two simulation approaches are used: an iterative simulation method and one based on a set of ordinary differential equations. Additional information is included from turbine performance maps taking into account condensation using Euler–Lagrange CFD simulations, which are presented. The iterative calculation approach is well suited to show the impact of condensation and moist air on the steady state thermodynamic cycle and yields a significant shift of the steady state operating line towards the surge line. It is shown that a substantial risk of surge occurs during transient deceleration manoeuvres triggered by a load step.
The air-management system of a proton exchange membrane fuel cell (PEMFC) is responsible for supplying the fuel cell stack with ambient air at appropriate conditions. The compressor of the air-management system can be partly driven by utilizing the fuel cell exhaust gas in a turbine. The fuel cell exhaust is partially or fully saturated with water vapor. When the exhaust gas is expanded in the turbine, supersaturation occurs. This leads to the nucleation of droplets and their subsequent growth by condensation. This study provides an overview and understanding of the various phenomena caused by condensation and liquid water in the turbine of a PEMFC air-management system. The basis for this work is previously published numerical simulations that focused on individual aspects of the above phenomena. The present work revisits these results and puts them in context to provide a comprehensive understanding. Important phenomena are the effects of condensation on turbine performance through phase change losses, release of latent heat and thermal throttling. In addition, the released latent heat offers a power potential for downstream turbine stages. Through these effects, condensation can also impact the entire air-management system. However, condensation may occur unevenly, causing a circumferential asymmetry of the turbine outflow. Liquid water in the turbine can lead to droplet erosion, corrosion, and water-induced damage. In summary, it is essential to consider condensation and liquid water when developing turbines for PEMFC air-management systems.