Over the last few decades, the attention on the safety of existing reinforced concrete (RC) structures has significantly increased. RC bridges, in particular, are highly relevant for strategic importance. In the Italian context, several of these bridges were built around 1960, when engineering practice commonly ignored or underestimated the presence of seismic actions. Therefore, it is fundamental to quantify as accurately as possible their seismic safety level with state-of-the-art analysis techniques. In this paper, an efficient procedure based on the multi-modal pushover analysis approach is proposed for the risk evaluation of several bridges of the Italian highway network. This procedure, tailored for portfolio level assessment, takes into account the non-linear behavior and the complex dynamic response this type of structure with limited computational effort. Three fundamental aspects are defined for the structural modelling of bridges, i.e., materials’ constitutive law, finite element type and nonlinear hinge models. Flexural and shear nonlinearities of piers are included to account for ductile and brittle damage potential. The standardized procedure guarantees consistent comparisons among different bridges of the same network in the form of risk indexes.
Throughout the last few decades, the scientific community has paid great attention to the structural safety of historical masonry constructions, which have high vulnerability with respect to seismic activities. Masonry towers are very widespread in Italy and represent an important part of the built heritage to be preserved. Different numerical methods with different levels of refinement were developed in the literature to evaluate their seismic performance. The present study shows a practical application of the seismic vulnerability evaluation of a masonry tower using different approaches. The aim is to provide practical suggestions to engineers for the successful evaluation of the performance of masonry towers under seismic loads. An in situ survey was performed to characterize the geometry of the structure and its constitutive material. All the collected information was introduced in a building information model, later used to generate different finite element models for the structural analyses. The global capacity of the structure was evaluated using three different models with different levels of complexity: the first simplified model is made of beam elements with cross-sections discretized in fibers; the second model is made of shell elements and uses a concrete damage plasticity model to describe the nonlinear masonry behavior; the third model adopts solid elements with a concrete smeared crack constitutive law. A preliminary eigen-frequency analysis is performed on the shell model to obtain some basic information about the structural behavior. Nonlinear static analyses were carried out for each model to understand the response of the tower under seismic loads, highlighting the main differences between the approaches. The behavior factor was evaluated on the basis of the analyses results and compared with the ones suggested by the Italian building code. The results showed that the towers do not satisfy the seismic demand required by the standards for all the considered models. Furthermore, the behavior factor calculated according to the Italian design code is overestimated, while the one evaluated by the simplified model is underestimated due to the neglection of the shear behavior. From all the analyzed configurations, the shell model resulted as a good compromise between reliable results and computation efficiency.
The preservation and definition of the correct retrofitting interventions of historic masonry buildings represents a relevant topic nowadays, especially in a country characterized by high seismicity zones. Considering the Italian Cultural Heritage, most of these buildings are constructed in ancient unreinforced masonry (URM) and showed a high level of vulnerability during the recent 2009 (L’Aquila), 2012 (Emilia Romagna) and 2016 (Centro Italia) earthquakes. In this paper, the seismic assessment of an historic masonry building damaged during 2016 Centro Italia seismic event is presented considering different types of retrofitting interventions. Starting from the results obtained by the post-earthquake survey, different finite element models have been implemented to perform linear and non-linear analyses useful to understand the seismic behaviour of the building and to define the appropriate retrofitting interventions. In particular, reinforced plaster layer and cement-based grout injections have been applied in each masonry wall of the building in order to improve their horizontal load-bearing capacity, and an additional wall made with Poroton blocks and M10 cement mortar has been built adjacent to the central stairwell. In addition, in view of the need to replace the roof seriously damaged during the seismic event, a cross-laminated roof solution characterized by a thickness equal to 14 cm (composed by seven layers, each 2 cm thick) has been proposed. The results show that the proposed retrofitting interventions have led to a significant improvement in the seismic behaviour of the building.