Myrthe Van Der Ven

Dr. Myrthe Van Der Ven


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2017 in Arthritis Research & Therapy
Verified
Journal Article
Open access
PDF file
MVMyrthe Van Der Ven
Myrthe Van Der Ven
MVM. van der Veer-Meerkerk
M. van der Veer-Meerkerk
DCD. F. Ten Cate
D. F. Ten Cate
NRN. Rasappu
N. Rasappu
MKM.R. Kok
M.R. Kok
JLJ. J. Luime
J. J. Luime
To decrease the burden of disease of rheumatoid arthritis (RA), patients at risk for RA need to be identified as early as possible, preferably when no clinically apparent synovitis can be detected. Up to now, it has been fairly difficult to identify those patients with arthralgia who develop inflammatory arthritis (IA), but recent studies using ultrasound (US) suggest that earlier detection is possible. We aimed to identify patients with arthralgia developing IA within 1 year using US to detect subclinical synovitis at first consultation. In a multi-centre cohort study, we followed patients with arthralgia with at least two painful joints of the hands, feet or shoulders without clinical synovitis over 1 year. Symptom duration was < 1 year, and symptoms were not explained by other conditions. At baseline and at 6 and 12 months, data were collected for physical examinations, laboratory values and diagnoses. At baseline, we examined 26 joints ultrasonographically (bilateral metacarpophalangeal joints 2–5, proximal interphalangeal joints 2–5, wrist and metatarsophalangeal joints 2–5). Scoring was done semi-quantitatively on greyscale (GS; 0–3) and power Doppler (PD; 0–3) images. US synovitis was defined as GS ≥ 2 and/or PD ≥ 1. IA was defined as clinical soft tissue swelling. Sensitivity and specificity were used to assess the diagnostic value of US for the development of IA. Univariate logistic regression was used to analyse the association between independent variables and the incidence of IA. For multivariate logistic regression, the strongest variables (p < 0.157) were selected. Missing values for independent variables were imputed. A total of 196 patients were included, and 159 completed 12 months of follow-up. Thirty-one (16%) patients developed IA, of whom 59% showed US synovitis at baseline. The sensitivity and specificity of US synovitis were 59% and 68%, respectively. If no joints were positive on US, negative predictive value was 89%. In the multivariate logistic regression, age (OR 1.1), the presence of morning stiffness for > 30 minutes (OR 3.3) and PD signal (OR 3.4) were associated with incident IA. The presence of PD signal, morning stiffness for > 30 minutes and age at baseline were independently associated with the development of IA. Regarding the value of US in the diagnostic workup of patients with early arthralgia at risk for IA, US did perform well in ruling out IA in patients who did not have US synovitis.

12 July 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TNThomas Johannes Nichting
Thomas Johannes Nichting
MBMaretha Bester
Maretha Bester
RJRohan Joshi
Rohan Joshi
Massimo MischiMassimo Mischi
Massimo Mischi
MVMyrthe Van Der Ven
Myrthe Van Der Ven
RVRik Vullings
Rik Vullings
Background: Researchers have long suspected a mutual interaction between maternal and fetal heart rhythms, referred to as maternal-fetal cardiac coupling (MFCC). While several studies have been published on this phenomenon, they vary in terms of methodologies, populations assessed, and definitions of coupling. Moreover, a clear discussion of the potential clinical implications is often lacking. Subsequently, we perform a scoping review to map the current state of the research in this field and, by doing so, form a foundation for future clinically oriented research on this topic.Methods: A literature search was performed in PubMed, Embase, and Cochrane. Filters were only set for language (English, Dutch, and German literature were included) and not for year of publication. After screening for the title and the abstract, a full-text evaluation of eligibility followed. All studies on MFCC were included which described coupling between heart rate measurements in both the mother and fetus, regardless of the coupling method used, gestational age, or the maternal or fetal health condition.Results: 23 studies remained after a systematic evaluation of 6,672 studies. Of these, 21 studies found at least occasional instances of MFCC. Methods used to capture MFCC are synchrograms and corresponding phase coherence indices, cross-correlation, joint symbolic dynamics, transfer entropy, bivariate phase rectified signal averaging, and deep coherence. Physiological pathways regulating MFCC are suggested to exist either via the autonomic nervous system or due to the vibroacoustic effect, though neither of these suggested pathways has been verified. The strength and direction of MFCC are found to change with gestational age and with the rate of maternal breathing, while also being further altered in fetuses with cardiac abnormalities and during labor.Conclusion: From the synthesis of the available literature on MFCC presented in this scoping review, it seems evident that MFCC does indeed exist and may have clinical relevance in tracking fetal well-being and development during pregnancy.

24 October 2013 in Arthritis Research & Therapy
Verified
Journal Article
Open access
PDF file
DCDavid F Ten Cate
David F Ten Cate
JLJolanda J Luime
Jolanda J Luime
MVMyrthe Van Der Ven
Myrthe Van Der Ven
JHJohanna Mw Hazes
Johanna Mw Hazes
KKKlazina Kooiman
Klazina Kooiman
JBJohannes G Bosch
Johannes G Bosch
Introduction: In many patients with rheumatoid arthritis (RA) subclinical disease activity can be detected with ultrasound (US), especially using power Doppler US (PDUS). However, PDUS may be highly dependent on the type of machine. This could create problems both in clinical trials and in daily clinical practice. To clarify how the PDUS signal differs between machines we created a microvessel flow phantom. Methods: The flow phantom contained three microvessels (150, 1000, 2000 microns). A syringe pump was used to generate flows. Five US machines were used. Settings were optimised to assess the lowest detectable flow for each US machine. Results: The minimal detectable flow velocities showed very large differences between the machines. Only two of the machines may be able to detect the very low flows in the capillaries of inflamed joints. There was no clear relation with price. One of the lower-end machines actually performed best in all three vessel sizes. Conclusions: We created a flow phantom to test the sensitivity of US machines to very low flows in small vessels. The sensitivity of the power Doppler modalities of 5 different machines was very different. The differences found between the machines are probably caused by fundamental differences in processing of the PD signal or internal settings inaccessible to users. Machines considered for PDUS assessment of RA patients should be tested using a flow phantom similar to ours. Within studies, only a single machine type should be used.

11 April 2017 in Rheumatology
Verified
Journal Article
Open access
PDF file
MVMyrthe Van Der Ven
Myrthe Van Der Ven
TKT. Martijn Kuijper
T. Martijn Kuijper
AGAndreas H. Gerards
Andreas H. Gerards
ITIlja Tchetverikov
Ilja Tchetverikov
AWAngelique E. Weel
Angelique E. Weel
JLJolanda J. Luime
Jolanda J. Luime
Objectives. Although RA patients achieve clinical remission, risk of flare still exists. Given the association between US synovitis and increased risk of flare, it is of clinical interest whether these patients report a different health status. Therefore, our aim was to evaluate the frequency of US remission in RA patients in clinical remission and to compare the health status of RA patients in clinical remission with those who were also in US remission. Methods. In a prospective study, we included 89 RA patients (aged >17 years) treated with a synthetic DMARD and a TNF inhibitor who were in remission (DAS in 44 joints ⩽2.4 and swollen joint count ⩽1). Demographic characteristics, swollen and tender joints, laboratory variables, US (MCP2–5, PIP2–5, wrists and MTP2–5) and patient-reported outcomes (general health, functional ability, fatigue, depression and anxiety, pain and morning stiffness) were recorded at two consecutive visits (3 months apart). US remission was defined as grey scale grade ⩽1 and power Doppler = 0. Results. At visit 1, 39% of patients were in US remission. At visit 2, 32% of patients were in US remission. At visit 1, functional ability (HAQ) was scored lower by patients in US remission (P = 0.029). At visit 2, HAQ scores were similar (P = 0.928). At visit 2, Hospital Anxiety and Depression Scale anxiety score and visual analog scale pain were significantly higher in patients in US remission. Similar levels were found for the other patient-reported outcomes. Conclusion. One-third of RA patients in clinical remission were in US remission. In our study population, we could not find a clear association between health status of RA patients and being in US remission.

1 January 2021 in Intelligence-Based Medicine
Verified
Journal Article
Open access
SOSebastiaan P. Oei
Sebastiaan P. Oei
RSRuud Jg. van Sloun
Ruud Jg. van Sloun
MVMyrthe Van Der Ven
Myrthe Van Der Ven
HKHendrikus Hm. Korsten
Hendrikus Hm. Korsten
MMMassimo Mischi
Massimo Mischi

23 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AGAlessandra Galli
Alessandra Galli
Elisabetta PeriElisabetta Peri
Elisabetta Peri
YZYijing Zhang
Yijing Zhang
RVRik Vullings
Rik Vullings
MVMyrthe Van Der Ven
Myrthe Van Der Ven
Massimo MischiMassimo Mischi
Massimo Mischi
Multi-channel measurements from the maternal abdomen acquired by means of dry electrodes can be employed to promote long-term monitoring of fetal heart rate (fHR). The signals acquired with this type of electrode have a lower signal-to-noise ratio and different artifacts compared to signals acquired with conventional wet electrodes. Therefore, starting from the benchmark algorithm with the best performance for fHR estimation proposed by Varanini et al., we propose a new method specifically designed to remove artifacts typical of dry-electrode recordings. To test the algorithm, experimental textile electrodes were employed that produce artifacts typical of dry and capacitive electrodes. The proposed solution is based on a hybrid (hardware and software) pre-processing step designed specifically to remove the disturbing component typical of signals acquired with these electrodes (triboelectricity artifacts and amplitude modulations). The following main processing steps consist of the removal of the maternal ECG by blind source separation, the enhancement of the fetal ECG and identification of the fetal QRS complexes. Main processing is designed to be robust to the high-amplitude motion artifacts that corrupt the acquisition. The obtained denoising system was compared with the benchmark algorithm both on semi-simulated and on real data. The performance, quantified by means of sensitivity, F1-score and root-mean-square error metrics, outperforms the performance obtained with the original method available in the literature. This result proves that the design of a dedicated processing system based on the signal characteristics is necessary for reliable and accurate estimation of the fHR using dry, textile electrodes.