Many industrial applications are recently utilizing the advantages of a common dc-bus-based multiple-drive (multidrive) system, such as low installation cost, space savings as well as improved reliability, and flexibility. One of the main drawbacks of such systems is the requirement for a bulky dc capacitor due to the presence of large dc-link current ripples from the harmonic interaction between these multidrive and pulsewidth modulation (PWM) switching. This problem not only increases the cost and volume of the dc-link capacitors but also decreases its lifetime, which must be considered in the design from the industrial aspect. This article proposes a new dc-bus capacitor design method for a multidrive system, focused on the capacitor sizing, cost reduction, and lifetime improvements. First, an analytical model to obtain the dc-link capacitor current in a multidrive system is proposed, which would aid the designers to configure the dc-capacitor current in systems having numerous multiple drives. Next, using the developed analytical model, the dc-link current harmonics are reduced through optimal interleaving of the fundamental output currents in addition to the phase shifting of the carrier waves of the parallel connected inverters. Finally, new capacitor sizing/design is proposed considering the lifetime, power loss, cost, and volume of the dc-link capacitor bank. The proposed approach reduces the volume and cost of dc-cap bank by 50%, and increases the lifetime by four years ($\sim$35 000 h), considering the worst-case scenarios. Experimental and analytical results are given for validation of the proposed method. The results could serve as a guideline for designing the dc-link capacitor in multidrive applications in a low-cost manner.
DC-connected parallel inverter systems are gaining popularity in industrial applications. However, such parallel systems generate excess current ripple (harmonics) at the DC-link due to harmonic interactions between the inverters in addition to the harmonics from the PWM switching. These DC-link harmonics cause the failure of fragile components such as DC-link capacitors. This paper proposes an interleaving scheme to minimize the current harmonics induced in the DC-link of such a system. First, the optimal phase-shift angle for the carrier signal is investigated using the analytical equations, which provides maximum capacitor current ripple cancellation (i.e., at the main switching frequency harmonic component). These optimally phase-shifted switching cycles lead to variations of the output current ripples, which, when summed together at the DC-link, result in the cancellations of the DC-link current ripples. The results show that when the carrier waves of the two inverters are phase-shifted by a 90° angle, the maximum high-frequency harmonic ripple cancellation occurs, which reduces the overall root-mean-square (RMS) value of the DC-capacitor current by almost 50%. The outcome of this proposed solution is a cost-effective DC-harmonics mitigating strategy for the industrial designers to practically configure multi-inverter systems, even when most of the drives are not operating at rated power levels. The experimental and simulation results presented in this paper verify the effectiveness of the proposed carrier-based phase-shifting scheme for two different configurations of common DC connected multi-converter systems.
In the current era, due to the energy shortage problems and economic problems that the humans face, the world has been looking for the alternatives of fossil fuels, and wind driven energy systems have been turning attention as a better electricity source. Wind turbine blades bear different types of loads such as aerodynamic loads, gravitational loads and centrifugal loads. These loads cause aerodynamic fatigue and vibration in blades, which leads to degradation of the rotor blades and thereby reducing the efficiency of the wind turbine system. This can be over-come by using a good pitch controller (PC) which will tune the attack angle of a wind turbine rotor blade into or out of the wind. In this paper, a pitch angle control strategy based on the fuzzy logic control is proposed to cope with the nonlinear characteristics of wind turbine as well as to reduce the loads on the blades. A mathematical model of wind turbine (pitch control system) is developed and is tested with Fuzzy-PID Controller and conventional PID Controller. After comparing the proposed strategy, the simulation results show that the Fuzzy-PID logic controller has better response in controlling the wind turbine pitch system through rejecting the disturbances and correcting uncertain factors associated with the system. Hence improving the efficiency of the wind turbine by controlling the pitch angle.
DC-connected parallel inverter systems are gaining popularity in industrial applications. However, such parallel systems generate excess current ripple (harmonics) at the DC-link due to harmonic interactions between the inverters in addition to the harmonics from the PWM switching. These DC-link harmonics cause the failure of fragile components such as DC-link capacitors. This paper proposes an interleaving scheme to minimize the current harmonics induced in the DC-link of such a system. The results show that when the carrier waves of the two inverters are phase-shifted by 90° angle, the maximum high-frequency harmonic ripple cancellation occurs, which reduces the overall RMS value of the DC-capacitor current.The outcome of this proposed solution is a cost-effective DC-harmonics mitigating strategy for the industrial designers to practically configuring multi-inverter systems, even when most of the drives are not operating at rated power levels. Experimental and simulation results presented in this paper verify the effectiveness of the proposed carrier-based phase-shifting scheme for two different configurations of common DC connected multi-converter systems.