Multi-level transformerless inverters are widely used in grid-tied PV systems since they characterized by higher efficiency and lower cost. In this context, new topologies, modulation, and control schemes were presented to solve problems of a common-mode voltage and leakage current. This work proposes a transformerless five-level inverter with zero leakage current and ability to reduce the harmonic output content for a grid-tied single-phase PV system. The neutral of the grid links to a common on which the negative and the positive terminals of the DC-link are connected via parasitic capacitors that can eliminate the leakage current. The proposed topology, with its inherent circuit structure, leads to boost the overall efficiency. Simulation and experimental results show almost zero leakage current and a high-quality output when maintaining balanced capacitor voltages on the DC-link input. The experimental results show 1.07% THD and 96.3% maximum efficiency when injecting a power of 1.1 kW that verify the performance of the proposed inverter with PV sources.
Periodic preventive maintenance of power transformer should be conducted for its health monitoring and early fault detection. Transformer oil is a vital element where its contents and properties need to be monitored during the service life of a power transformer. This paper presents an optical spectroscopy measurement from 200 nm to 3300 nm to characterize the transformer oil, which were sampled from the main tanks and ‘on-load tap changer’ of power transformers. The correlation of the optical characteristics in the range of 2120 nm to 2220 nm to the Dissolved Gas Analysis results and Duval Triangle interpretation demonstrates that the low energy electrical discharges, high energy electrical discharges as well as the thermal faults rated at temperatures above 700°C in power transformers can be accurately predicted. For faster and accurate analysis of fault prediction, a data mining analytics tool was constructed using Rapid Miner server to analyze and verify the predictions for a total of 108 oil samples. For the optimization, continuous iterations were performed to determine the best absorbance-wavelength combination that can improve the accuracy of the prediction. The performance of the optical spectroscopy technique integrated with data analytic tool was analyzed and it was found that the technique contributes to a high accuracy of 98.1% in fault prediction. It is a cost-effective and quicker complementing approach to carry out pre-screening of the transformer oil in order to know the condition of the power transformers based on the transformer oil’s optical characteristics.
This paper presents a comparative analysis of different earthing designs’ performances, with particular interest on the use of earthing enhancing compound (EEC) for a selected earthing design of 500 kV transmission towers in a rocky soil, using the SESCAD tool of the Current distribution, electromagnetic field grounding and soil structure analysis (CDEGS) software. The simulation included the interpretation of soil profile and comparison between designs A, B and C, which are currently used for the 500 kV tower footing resistance (TFR) improvement. Results showed each design had reduced the TFR by 66%, 54.7% and 63.2% for the towers T42, T48 and T50, respectively. In some cases, further improvement of TFR is required, especially in the rocky area where the soil resistivity (SR) value is of more than 500 Ω⋅m. In this case, EEC was used in Design C, encasing both the vertical and horizontal electrodes, and it reduced the TFR further by 16% to 20%. The characteristics of the soil and earthing arrangement design play an important role in achieving a low TFR value, which is directly proportional to the backflashover occurrence and thus to the transmission line performance.
Improving a tower earthing system by reducing the impedance is an effective solution to prevent back flashover from occurring and thus maintaining the sustainable operation of power supply. Knowledge of the soil and earthing structure is an important element when designing an earthing system and to determine the parameters of a transmission line (TL). This paper presents the computation of soil structure interpretation based on several earthing designs using current distribution, electromagnetic interference, grounding, and soil structure analysis (CDEGS) software. The results showed that each tower has a multi-layer soil structure and it was also found that the soil resistivity at the surface layer strongly affected the earthing impedance. Subsequently, it was demonstrated that soil structure and the earthing design arrangement are the two parameters that significantly affected the ground potential rise (GPR). This aspect affects the resistance and impulse impedance of a tower and thus influences the performance of the TL system when subjected to lightning strike, which is undoubtedly one of the major culprits of power outages in Malaysia.
Partial discharge (PD) analysis is widely adopted for assessing the condition of the insulation systems within high voltage (HV) transformers. Different PD sources have different effects on the insulation condition of HV transformers. In a typical field environment, multiple PD sources may occur in HV transformer simultaneously. Therefore, source classification is very important to identify the types of defects causing discharges in a HV transformer. In recent years, several classification techniques have been proposed for application in PD analysis. This paper proposes automatic techniques to classify and localize multiple PD sources within a HV transformer winding. The proposed processing technique relies on the assumption that the PD pulses generated from different defects exhibit unique waveform characteristics. Surface and void discharges which are the common types of defect events that may occur within HV transformer windings have been experimentally generated. Each pair combination was injected simultaneously into different locations along the HV transformer winding with analysis of two wideband radio frequency current transformers (RFCTs) data captured from each end of the winding. After PD pulses extraction and wavelet analysis, this paper presents two approaches using two different methods to accurately locate multiple PD sources within an HV transformer winding. The performances of the two approaches for this type of application are presented.
Partial discharge (PD) analysis is one of the most important techniques to evaluate the condition of the insulation systems within high voltage (HV) transformers. However, in typical field environments, measurements of PD signals can be distorted by noise sources. This greatly reduces the ability to identify PD sources in HV transformer windings. Therefore, de-noising methods in PD analysis are very important. In recent years, several noise reduction techniques have been proposed for application in PD analysis. The common types of discharge events that may occur within high voltage transformer windings namely void, surface, corona and floating discharge have been experimentally generated. Each type of discharge was injected into different locations along a HV transformer winding and then measured using two wideband radio frequency current transformers (RFCTs) positioned at each end of the winding. Then, either the Discrete Wavelet Transform (DWT) and Stationary Wavelet Transform (SWT) or Mathematical Morphology (MM) were applied to reduce the noise in the raw captured PD signals. This paper presents the comparison of performance of the techniques in terms of noise reduction for this type of application.