Yawar Ali Sheikh

Dr. Yawar Ali Sheikh

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Sarosh AhmadSarosh Ahmad
Sarosh Ahmad
HBHichem Boubakar
Hichem Boubakar
SNSalman Naseer
Salman Naseer
MAMohammad Ehsanul Alim
Mohammad Ehsanul Alim
YSYawar Ali Sheikh
Yawar Ali Sheikh
Naser Ojaroudi ParchinNaser Ojaroudi Parchin
Naser Ojaroudi Parchin
A printed monopole antenna for millimeter-wave applications in the 5G frequency region is described in this research. As a result, the proposed antenna resonates in three frequency bands that are designated for 5G communication systems, including 28 GHz, 38 GHz, and 60 GHz (V band). For the sake of compactness, the coplanar waveguide (CPW) method is used. The overall size of the proposed tri-band antenna is 4 mm × 3 mm × 0.25 mm. Using a watch strap and human tissue, such as skin, the proposed antenna gives steady results. At 28 GHz, 38 GHz, and 60 GHz, the antenna’s gain is found to be 5.29 dB, 7.47 dB, and 9 dB, respectively. The overall simulated radiation efficiency is found to be 85% over the watch strap. Wearable devices are a great fit for the proposed tri-band antenna. The antenna prototype was built and tested in order to verify its performance. It can be observed that the simulated and measured results are in close contact. According to our comparative research, the proposed antenna is a good choice for smart 5G devices because of its small size and simple structure, as well as its high gain and radiation efficiency.

21 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
INIbrahime Hassan Nejdi
Ibrahime Hassan Nejdi
SBSeddik Bri
Seddik Bri
MMMohamed Marzouk
Mohamed Marzouk
Sarosh AhmadSarosh Ahmad
Sarosh Ahmad
YRYoussef Rhazi
Youssef Rhazi
Mousa I HusseinMousa I Hussein
Mousa I Hussein
The present study proposes a new, highly efficient fractal antenna with ultra-wideband (UWB) characteristics. The proposed patch offers a wide simulated operating band that reaches 8.3 GHz, a simulated gain that varies between 2.47 and 7.73 dB throughout the operating range, and a high simulated efficiency that comes to 98% due to the modifications made to the antenna geometry. The modifications carried out on the antenna are composed of several stages, a circular ring extracted from a circular antenna in which four rings are integrated and, in each ring, four other rings are integrated with a reduction factor of 3/8. To further improve the adaptation of the antenna, a modification of the shape of the ground plane is carried out. In order to test the simulation results, the prototype of the suggested patch was built and tested. The measurement results validate the suggested dual ultra-wideband antenna design approach, which demonstrates good compliance with the simulation. From the measured results, the suggested antenna with a compact volume of 40 × 24.5 × 1.6 mm3 asserts ultra-wideband operation with a measured impedance bandwidth of 7.33 GHz. A high measured efficiency of 92% and a measured gain of 6.52 dB is also achieved. The suggested UWB can effectively cover several wireless applications such as WLAN, WiMAX, and C and X bands.

1 September 2020 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
YSYawar Ali Sheikh
Yawar Ali Sheikh
Arslan Dawood ButtArslan Dawood Butt
Arslan Dawood Butt
KPKashif nisar Paracha
Kashif nisar Paracha
Ahmed Bilal AwanAhmed Bilal Awan
Ahmed Bilal Awan
Abdul Rauf BhattiAbdul Rauf Bhatti
Abdul Rauf Bhatti
MZMuhammad Zubair
Muhammad Zubair
This work presents a lightweight and minimally invasive cooling system design with forced water cooling, which can improve photovoltaic (PV) system performance by thoroughly reducing the temperature of its solar cells. This design is an improved version of traditional PV-thermal cooling systems that are bulky and mostly limited to land-based applications. Thermal and fluid flow analyses of this system have been presented to numerically assess output efficiency improvement with a commercial solar panel. The proposed serpentine cooling block structure has been optimized to maintain module efficiency better than Standard Testing Conditions (STC) under all conditions. For a 395 W commercial solar panel, an output power improvement of up to 49.4 W (14.29%) at an irradiance level of 1000 W/m2 at an ambient temperature of 35   ° C has been achieved. The corresponding water pump operation and associated losses are limited to a maximum of 8.5 W/module. The impact of cooling system performance has also been evaluated for the region of Mangla Dam Lake, Pakistan, where an annual increase in electricity output of around 9.58% is foreseen. Consequently, this work is envisioned to provide guidance on increasing the efficiency of the PV system to those who would install it near water reservoirs.

1 November 2021 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
YSYawar Ali Sheikh
Yawar Ali Sheikh
MMMuhammad Umar Maqbool
Muhammad Umar Maqbool
Arslan Dawood ButtArslan Dawood Butt
Arslan Dawood Butt
Abdul Rauf BhattiAbdul Rauf Bhatti
Abdul Rauf Bhatti
Ahmed Bilal AwanAhmed Bilal Awan
Ahmed Bilal Awan
MKMuhammad Murad Khan
Muhammad Murad Khan
Solar energy is one of the most abundant and widely available renewable energy sources. It can be harnessed using photovoltaic panels on top of buildings to reduce dependence on the electrical grid and to achieve the status of net-zero energy building. However, the rooftop coverage by solar panels can modify the heat interface between the roof surface and its surrounding environment. This can alter a building's energy demand for heating, ventilation, and air conditioning. Such an impact on a building's energy demand is highly correlated with its roof structure and climate. In this work, three-dimensional distributed thermal models of the bare and photovoltaic added rooftop ensembles are developed to simulate the heat gain/loss associated with the roof structure for monthly mean diurnal cycles. This work considers the low-rise, high-density building style and hot semi-arid climate of Faisalabad, Pakistan to quantify the impact of a rooftop photovoltaic on the roof-related thermal load of a building. Results depict a 42.58% reduced heat loss from the photovoltaic added roof structure during winter and a 1.98% increase in heat gain during summer. This reduces the electricity demand for indoor heating during winter and slightly increases it for indoor cooling during summer. The obtained results prove the significance of this work and provide guidelines to energy policymakers, the construction industry, and energy consumers. Moreover, this work provides a better understanding of the building's energy demand for heating, ventilation, and air conditioning with a rooftop photovoltaic system and its net-zero energy requirements, which are pivotal for modern construction.

8 May 2021 in Technology and Economics of Smart Grids and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
Abdul Rauf BhattiAbdul Rauf Bhatti
Abdul Rauf Bhatti
Arslan Dawood ButtArslan Dawood Butt
Arslan Dawood Butt
YSYawar Ali Sheikh
Yawar Ali Sheikh
KPKashif nisar Paracha
Kashif nisar Paracha
NZNaila Zareen
Naila Zareen