Dalia Elsheakh

Prof. Dalia Elsheakh

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
Dalia ElsheakhDalia Elsheakh
Dalia Elsheakh
RMRawda A. Mohamed
Rawda A. Mohamed
OFOmar M. Fahmy
Omar M. Fahmy
Khaled Adel EzzatKhaled Adel Ezzat
Khaled Adel Ezzat
Angie EldamakAngie Eldamak
Angie Eldamak
This paper presents the development of a new complete wearable system for detecting breast tumors based on fully textile antenna-based sensors. The proposed sensor is compact and fully made of textiles so that it fits conformably and comfortably on the breasts with dimensions of 24 × 45 × 0.17 mm3 on a cotton substrate. The proposed antenna sensor is fed with a coplanar waveguide feed for easy integration with other systems. It realizes impedance bandwidth from 1.6 GHz up to 10 GHz at |S11| ≤ −6 dB (VSWR ≤ 3) and from 1.8 to 2.4 GHz and from 4 up to 10 GHz at |S11| ≤ −10 dB (VSWR ≤ 2). The proposed sensor acquires a low specific absorption rate (SAR) of 0.55 W/kg and 0.25 W/kg at 1g and 10 g, respectively, at 25 dBm power level over the operating band. Furthermore, the proposed system utilizes machine-learning algorithms (MLA) to differentiate between malignant tumor and benign breast tissues. Simulation examples have been recorded to verify and validate machine-learning algorithms in detecting tumors at different sizes of 10 mm and 20 mm, respectively. The classification accuracy reached 100% on the tested dataset when considering |S21| parameter features. The proposed system is vision as a “Smart Bra” that is capable of providing an easy interface for women who require continuous breast monitoring in the comfort of their homes.

21 March 2024 in IEEE Access
Verified
Journal Article
Open access
Dalia ElsheakhDalia Elsheakh
Dalia Elsheakh
OFOmar M. Fahmy
Omar M. Fahmy
MFMina Farouk
Mina Farouk
Khaled Adel EzzatKhaled Adel Ezzat
Khaled Adel Ezzat
Angie EldamakAngie Eldamak
Angie Eldamak
Wearable devices are currently of great importance in developing health management and care applications and devices especially for early breast cancer detection (BCD). This is supported by the novel innovations in materials and techniques to construct highly accurate and comfortable biosensors for wearables. In this paper, the proposed flexible sensor is integrated with a Bra to realize a wearable breast cancer detection system. The proposed antenna-based sensor is composed of a CPW monopole antenna with an overall compact size of 24 × 45 mm 2 on flexible PCB Roger substrate with thickness 0.17 mm. The proposed sensors have enough bandwidth from 1.5 to 8 GHz at -6 dB reflection coefficient and conformal structure for biological structures and biocompatibility. The specific absorption rate (SAR) has been calculated and measured for the proposed sensor with a value of 0.75 W/kg at 0 dBm to ensure safety level. For testing, real shaped rubber phantoms from medical school enables the dynamic combination of breast and tumor to create test scenarios for breast cancer detection. 2×2 antenna-based sensors elements are placed around the breast phantom to gather data on scattering parameters for tumor characterization. Several simulation and measurement scenarios are presented to validate detection, optimum number of sensors to be used as well as training data for developed detection algorithms. Artificial intelligence techniques are used among which the CAT-Boost technique for scanning collected data and identifying the undesired tumor component inside the breast.

29 March 2021 in IEEE Access
Verified
Journal Article
Open access
NENermeen Ahmed Eltresy
Nermeen Ahmed Eltresy
AEAbd Elhamid M. Abd Elhamid
Abd Elhamid M. Abd Elhamid
Dalia ElsheakhDalia Elsheakh
Dalia Elsheakh
HEHadia M. Elhennawy
Hadia M. Elhennawy
EAEsmat Adbel-fattah Abdallah
Esmat Adbel-fattah Abdallah
A transparent antenna array based on silver sandwiched indium tin oxide (AgITO) heterostructure thin films is presented. The AgITO is sputtered on both sides of soda-lime glass (SLG) substrate, and the three thin films deposition parameters are optimized to obtain very low ohmic interfacial contact resistance of less than 1 Ω/Sq. AgITO promotes thin film-based transparent microstrip structure of the proposed antenna array as well as the transparent T-junction power divider. Furthermore, AgITO microstrip as well as opaque single element antenna as reference antennas for a transparent array are presented. The proposed array has wide bandwidth promoting radio frequency energy harvesting at Wi-Fi 2.4, LTE 2600, WLAN, WiMAX and the expected 5G mid-bands. Moreover, it could be functionalized for wireless transmission within the previously mentioned bands. The transparent AgITO array has 5 dBi gain value against 2.3 dBi for the transparent AgITO single element antenna at 5.8 GHz. The array was utilized for radiofrequency energy harvesting, obtaining DC output volt=161.4 mV with a conversion efficiency of 32.9% at 5.8 GHz with RF received power of -10 dBm.

9 May 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MFMariam Farouk
Mariam Farouk
AEAnwer S. Abd El-Hameed
Anwer S. Abd El-Hameed
AEAngie R. Eldamak
Angie R. Eldamak
Dalia ElsheakhDalia Elsheakh
Dalia Elsheakh
The potential for continuous non-invasive blood glucose monitoring has attracted a lot of interest in the field of medical diagnostics. This paper provides a new shape of a dual-band bandpass filter (DBBPF) acting as a microwave transmission line sensor for continuous non-invasive blood glucose monitoring operating at 2.45 and 5.2 GHz. The proposed system uses the interaction between biological tissues and microwave signals to correctly assess blood glucose levels. The proposed dual-band bandpass filter (DBBPF), comprises three split ring resonator (SRR) cells with different dimensions. It is designed to operate as a sensor with improved sensitivity, compact dimensions, and a high-quality factor. It also ensures a reasonable bandwidth for lower and higher bands of 8.6 and 2%, respectively in the industrial, scientific, medical band, and the wireless local area network (ISM and WLAN) Bands. A dual-band filter enhances measurement sensitivity and specificity by targeting specific frequency ranges where glucose exhibits distinctive dielectric responses, thereby providing redundant data points for accurate glucose level determination. Glucose concentrations can be evaluated by measuring the changes in the dielectric properties of blood by sending microwave waves through the body and assessing the collected S-parameter signals. The measurement parameters encompass the reflection, phase, magnitude, as well as transmission parameters. This yields multiple evaluations of the glucose-induced alterations. Simulations are validated through laboratory measurements incorporating a phantom finger model for capturing realistic outcomes. Machine learning models are employed to analyze the sensor data, improving the accuracy of diabetes detection. Simulations are validated through laboratory measurements incorporating a phantom finger model for capturing realistic outcomes. A Cole-Cole model, implemented using MATLAB, is utilized for the phantom finger model. The main results reveal the success of the proposed transmission-based microwave glucose sensing, with a remarkable sensitivity of 1 ~ 1.5 dB for glucose level change up to 200 mg/dL.

15 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
NENermeen Ahmed Eltresy
Nermeen Ahmed Eltresy
Osama Mohammad Abd Al-Hameed DardeerOsama Mohammad Abd Al-Hameed Dardeer
Osama Mohammad Abd Al-Hameed Dardeer
AAAwab Al-Habal
Awab Al-Habal
EEEsraa Elhariri
Esraa Elhariri
AHAli H. Hassan
Ali H. Hassan
EAEsmat Adbel-fattah Abdallah
Esmat Adbel-fattah Abdallah
Museum contents are vulnerable to bad ambience conditions and human vandalization. Preserving the contents of museums is a duty towards humanity. In this paper, we develop an Internet of Things (IoT)-based system for museum monitoring and control. The developed system does not only autonomously set the museum ambience to levels that preserve the health of the artifacts and provide alarms upon intended or unintended vandalization attempts, but also allows for remote ambience control through authorized Internet-enabled devices. A key differentiating aspect of the proposed system is the use of always-on and power-hungry sensors for comprehensive and precise museum monitoring, while being powered by harvesting the Radio Frequency (RF) energy freely available within the museum. This contrasts with technologies proposed in the literature, which use RF energy harvesting to power simple IoT sensing devices. We use rectenna arrays that collect RF energy and convert it to electric power to prolong the lifetime of the sensor nodes. Another important feature of the proposed system is the use of deep learning to find daily trends in the collected environment data. Accordingly, the museum ambience is further optimized, and the system becomes more resilient to faults in the sensed data.

21 January 2023 in Telecommunication Systems
Verified
Journal Article
Open access
PDF file
Dalia ElsheakhDalia Elsheakh
Dalia Elsheakh
SASoha A. Alsherif
Soha A. Alsherif
Angie EldamakAngie Eldamak
Angie Eldamak
This paper presents two flexible monopole antennas implemented on cotton substrate as sensors designed for radar-based microwave imaging and particularly breast imaging systems. The flexible antennas are basic building block of a radar-based microwave imaging system that could be integrated in clothes. Thus, these low-cost textile sensors could be used by women for self-monitoring and early breast cancer detection at an affordable price. The ultra-wideband fully textile sensors are designed as rectangular and circular monopole antennas. Both sensors have an impedance bandwidth $$\le $$ ≤ − 10 dB from 2.2 to 8 GHz with an overall footprint of 50 × 50 mm2. Simulations for antenna in proximity to breast model with and without tumor as well as bending capacity are performed. The simulations are complemented with fabrication of a breast phantom and a tumor sample with parameters that mimic these of the human breast’s healthy and malignant tissue. Measurements are compared to simulation results as well as the performance of antenna before and after subjected to washing. Finally, the specific absorption rate is also calculated and measured to ensure safety for on-body deployment. The proposed work demonstrates the potential to develop wearable microwave imaging system using fully textile antennas.