Water content is a key parameter to monitor in nuclear waste repositories such as the planed underground repository in Bure, France, in the Callovo‐Oxfordian (COx) clay formation. High‐frequency electromagnetic (HF‐EM) measurement techniques, i.e., time or frequency domain reflectometry, offer useful tools for quantitative estimation of water content in porous media. However, despite the efficiency of HF‐EM methods, the relationship between water content and dielectric material properties needs to be characterized. Moreover, the high amount of swelling clay in the COx clay leads to dielectric relaxation effects which induce strong dispersion coupled with high absorption of EM waves. Against this background, the dielectric relaxation behavior of the clay rock was studied at frequencies from 1 MHz to 10 GHz with network analyzer technique in combination with coaxial transmission line cells. For this purpose, undisturbed and disturbed clay rock samples were conditioned to achieve a water saturation range from 0.16 to nearly saturation. The relaxation behavior was quantified based on a generalized fractional relaxation model under consideration of an apparent direct current conductivity assuming three relaxation processes: a high‐frequency water process and two interface processes which are related to interactions between the aqueous pore solution and mineral particles (adsorbed/hydrated water relaxation, counter ion relaxation and Maxwell‐Wagner effects). The frequency‐dependent HF‐EM properties were further modeled based on a novel hydraulic‐mechanical‐electromagnetic coupling approach developed for soils. The results show the potential of HF‐EM techniques for quantitative monitoring of the hydraulic state in underground repositories in clay formations.
Although optical fiber sensors have been developed for 30 years, there is a gap between lab experiments and field applications. This article focuses on specific methods developed to evaluate the whole sensing chain, with an emphasis on (i) commercially-available optoelectronic instruments and (ii) sensing cable. A number of additional considerations for a successful pairing of these two must be taken into account for successful field applications. These considerations are further developed within this article and illustrated with practical applications of water leakage detection in dikes and concrete structures monitoring, making use of distributed temperature and strain sensing based on Rayleigh, Raman, and Brillouin scattering in optical fibers. They include an adequate choice of working wavelengths, dedicated localization processes, choices of connector type, and further include a useful selection of traditional reference sensors to be installed nearby the optical fiber sensors, as well as temperature compensation in case of strain sensing.
25 September 2015 in Smart Materials and Structures
Distributed optical fiber systems (DOFSs) are an emerging and innovative technology that allows long-range and continuous strain/temperature monitoring with a high resolution. Sensing cables are either surface-mounted or embedded into civil engineering structures to ensure long-term structural monitoring and early crack detection. However, strain profiles measured in the optical fiber (OF) may differ from the actual strain in the structure due to the shear transfer through the intermediate material layers between the OF and the host material (i.e., in the protective coating of the sensing cable and in the adhesive). Therefore, OF sensors need to be qualified to provide accurate quantitative strain measurements. This study presents a methodology for the qualification of a DOFS. This qualification is achieved through the calculation of the so-called mechanical transfer function (MTF), which relates the strain profile in the OF to the actual strain profile in the structure. It is proposed to establish a numerical modeling of the system, in which the mechanical parameters are calibrated from experiments. A specific surface-mounted sensing cable connected to an optical frequency domain reflectometry interrogator is considered as a case study. It was found that (i) tensile and pull-out tests can provide detailed information about materials and interfaces of the numerical model; (ii) the calibrated model made it possible to compute strain profiles along the OF and therefore to calculate the MTF of the system; (iii) the results proved to be consistent with experimental data collected on a cracked concrete beam during a four-point bending test. This paper is organized as follows: first, the technical background related to DOFSs and interrogators is briefly recalled, the MTF is defined and the above-mentioned methodology is presented. In the second part, the methodology is applied to a specific cable. Finally, a comparison with experimental evidence validates the proposed approach.