The authors report on the realization of a novel methodology for refractometry—GAs modulation refractometry (GAMOR)—that decreases the influence of drifts in Fabry Perot cavity refractometry. The instrumentation is based on a dual Fabry-Perot cavity refractometer in which the beat frequency between the light fields locked to two different cavities, one measurement and one reference cavity, is measured. The GAMOR methodology comprises a process in which the measurement cavity sequentially is filled and evacuated while the reference cavity is constantly evacuated. By performing beat frequency measurements both before and after the finite-pressure measurement, zero point references are periodically created. This opens up for high precision refractometry under nontemperature-stabilized conditions. A first version of an instrumentation based on the GAMOR methodology has been realized and its basic performance has been scrutinized. The refractometer consists of a Zerodur cavity-block and tunable narrow linewidth fiber lasers operating within the C34 communication channel (i.e., around 1.55 μm) at which there are a multitude of fiber coupled off-the-shelf optical, electro-optic, and acousto-optic components. The system is fully computer controlled, which implies it can perform unattended gas assessments over any foreseeable length of time. When applied to a system with no active temperature stabilization, the GAMOR methodology has demonstrated a 3 orders of magnitude improvement of the precision with respect to conventional static detection. When referenced to a dead weight pressure scale the instrumentation has demonstrated assessment of pressures in the kilo-Pascal range (4303 and 7226 Pa) limited by white noise with standard deviations in the 3.2N−1/2–3.5N−1/2 mPa range, where N is the number of measurement cycles (each being 100 s long). For short measurement times (up to around 103 s), the system exhibits a (1σ) total relative precision of 0.7 (0.5) ppm for assessment of pressures in the 4 kPa region and 0.5 (0.4) ppm for pressures around 7 kPa, where the numbers in parentheses represent the part of the total noise that has been attributed to the refractometer. As long as the measurement procedure is performed over short time scales, the inherent properties of the GAMOR methodology allow for high precision assessments by the use of instrumentation that is not actively temperature stabilized or systems that are affected by outgassing or leaks. They also open up for a variety of applications within metrology; e.g., transfer of calibration and characterization of pressure gauges, including piston gauges.
Gas modulation refractometry (GAMOR) is a methodology that can mitigate fluctuations and drifts in refractometry. This can open up for the use of non-conventional cavity spacer materials. In this paper, we report a dual-cavity system based on Invar that shows better precision for assessment of pressure than a similar system based on Zerodur. This refractometer shows for empty cavity measurements, up to s, a white noise response (for ) of 3 mPa . At 4303 Pa, the system has a minimum Allan deviation of 0.34 mPa (0.08 ppm) and a long-term stability (24 h) of 0.7 mPa. This shows that the GAMOR methodology allows for the use of alternative cavity materials.
28 June 2021 in Journal of Vacuum Science & Technology B
By measuring the refractivity and the temperature of a gas, its pressure can be calculated from fundamental principles. The most sensitive instruments are currently based on Fabry–Perot cavities where a laser is used to probe the frequency of a cavity mode. However, for best accuracy, the realization of such systems requires exceptional mechanical stability. Gas modulation refractometry (GAMOR) has previously demonstrated an impressive ability to mitigate the influence of fluctuations and drifts whereby it can provide high-precision (sub-ppm, i.e., sub-parts-per-million or sub-10−6) assessment of gas refractivity and pressure. In this work, two independent GAMOR-based refractometers are individually characterized, compared to each other, and finally compared to a calibrated dead weight piston gauge with respect to their abilities to assess pressure in the 4–25 kPa range. The first system, referred to as the stationary optical pascal (SOP), uses a miniature fixed point gallium cell to measure the temperature. The second system, denoted the transportable optical pascal (TOP), relies on calibrated Pt-100 sensors. The expanded uncertainty for assessment of pressure (k=2) was estimated to, for the SOP and TOP, [(10mPa)2+(10×10−6P)2]1/2 and [(16mPa)2+(28×10−6P)2]1/2, respectively. While the uncertainty of the SOP is mainly limited by the uncertainty in the molar polarizability of nitrogen (8 ppm), the uncertainty of the TOP is dominated by the temperature assessment (26 ppm). To verify the long-term stability, the systems were compared to each other over a period of 5 months. It was found that all measurements fell within the estimated expanded uncertainty (k=2) for comparative measurements (27 ppm). This verified that the estimated error budget for the uncorrelated errors holds over this extensive period of time.
1 September 2020 in Journal of Vacuum Science & Technology B
A novel procedure for a robust assessment of cavity deformation in Fabry–Pérot (FP) refractometers is presented. It is based on scrutinizing the difference between two pressures: one assessed by the uncharacterized refractometer and the other provided by an external pressure reference system, at a series of set pressures for two gases with dissimilar refractivity (here, He and N2). By fitting linear functions to these responses and extracting their slopes, it is possible to construct two physical entities of importance: one representing the cavity deformation and the other comprising a combination of the systematic errors of a multitude of physical entities, viz., those of the assessed temperature, the assessed or estimated penetration depth of the mirror, the molar polarizabilities, and the set pressure. This provides a robust assessment of cavity deformation with small amounts of uncertainties. A thorough mathematical description of the procedure is presented that serves as a basis for the evaluation of the basic properties and features of the procedure. The analysis indicates that the cavity deformation assessments are independent of systematic errors in both the reference pressure and the assessment of gas temperature and when the gas modulation refractometry methodology is used that they are insensitive to gas leakages and outgassing into the system. It also shows that when a high-precision (sub-ppm) refractometer is characterized according to the procedure, when high purity gases are used, the uncertainty in the deformation contributes to the uncertainty in the assessment of pressure of N2 with solely a fraction (13%) of the uncertainty of its molar polarizability, presently to a level of a few ppm. This implies, in practice, that cavity deformation is no longer a limiting factor in FP-based refractometer assessments of pressure of N2.
By measuring the refractivity and the temperature of a gas, its pressure can be assessed from fundamental principles. The highest performing instruments are based on Fabry–Perot cavities (FPC). Gas modulation refractometry (GAMOR) is a methodology that has the ability to reduce the influence of disturbances to such an extent that high-precision (sub-parts-per-million) assessments of pressure can be made by the use of FPCs of Invar. To allow for high accuracy assessments, it is of importance to assess the uncertainty contribution from the thermodynamic effects that are associated with the gas filling and emptying of the cavity (pV-work). This paper presents a detailed scrutiny of the influence of the gas exchange process on the assessment of gas temperature on an Invar-based dual-FPC (DFPC) instrumentation. It is shown that by virtue of a combination of a number of carefully selected design entities (a small cavity volume with a bore radius of 3 mm, a spacer material with high heat capacitance, large thermal conductivity, and no regions that are connected with low thermal conductance, i.e. no heat islands, and a continuous assessment of temperature of the cavity spacer) the system is not significantly affected by pV-work. Simulations show that 10 s after the filling all temperature gradients in the system are well into the sub-mK range. Experiments support that refractivity assessments initiated after 40 s are not significantly affected by the pV-work. The analysis given in this work indicates that an upper limit for the influence of pV-work on the Invar-based DFPC system using 100 s long gas modulation cycles is 0.5 mK/100 kPa (or 1.8 ppm/100 kPa). Consequently, thermodynamic effects will not be a limiting factor when the Invar-based DFPC GAMOR system is used for assessments of pressure or as a primary pressure standard up to atmospheric pressures.
By measuring the refractivity and the temperature of a gas, its pressure can be assessed from fundamental principles. The highest performing instruments are based on Fabry–Perot cavities where a laser is used to probe the frequency of a cavity mode, which is shifted in relation to the refractivity of the gas in the cavity. Recent activities have indicated that such systems can demonstrate an extended uncertainty in the 10 ppm (parts-per-million or 10−6) range. As a means to reduce the influence of various types of disturbances (primarily drifts and fluctuations) a methodology based on modulation, denoted gas modulation refractometry (GAMOR), has recently been developed. Systems based on this methodology are in general high-performance, e.g. they have demonstrated precision in the sub-ppm range, and they are sturdy. They can also be made autonomous, allowing for automated and unattended operation for virtually infinite periods of time. To a large degree, the development of such instruments depends on the access to modern photonic components, e.g. narrow line-width lasers, electro- and acousto-optic components, and various types of fiber components. This work highlights the role of such modern devices in GAMOR-based instrumentation and provides a review on the recent development of such instruments in Sweden that has been carried out in a close collaboration between a research institute and the Academy. It is shown that the use of state-of-the-art photonic devices allows sturdy, automated and miniaturized instrumentation that, for the benefit of industry, can serve as standards for pressure and provide fast, unattended, and calibration-free pressure assessments at a fraction of the present cost.