Jen-Yuan (James) Chang

Prof. Dr. Jen-Yuan (James) Chang

Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2021 in ACS Applied Nano Materials
Verified
Journal Article
Closed access
ARAkash S. Rasal
Akash S. Rasal
SYSudesh Yadav
Sudesh Yadav
AYAnchal Yadav
Anchal Yadav
AKAnil A. Kashale
Anil A. Kashale
SMSubrahmanya Thagare Manjunatha
Subrahmanya Thagare Manjunatha
JCJia-Yaw Chang
Jia-Yaw Chang

14 April 2017 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
YYYueh-Yun Yao
Yueh-Yun Yao
GGGangaraju Gedda
Gangaraju Gedda
WGWubshet Mekonnen Girma
Wubshet Mekonnen Girma
CYChia-Liang Yen
Chia-Liang Yen
YLYong-Chien Ling
Yong-Chien Ling
JCJia-Yaw Chang
Jia-Yaw Chang

5 March 2019 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
CZChao Zheng
Chao Zheng
KZKe Zhu
Ke Zhu
Susana Cardoso De FreitasSusana Cardoso De Freitas
Susana Cardoso De Freitas
Jen-Yuan (James) ChangJen-Yuan (James) Chang
Jen-Yuan (James) Chang
JDJoseph E. Davies
Joseph E. Davies
Philip PongPhilip Pong
Philip Pong
Magnetoresistive (MR) sensors have been identified as promising candidates for the development of high-performance magnetometers due to their high sensitivity, low cost, low power consumption, and small size. The rapid advance of MR sensor technology has opened up a variety of MR sensor applications. These applications are in different areas that require MR sensors with different properties. Future MR sensor development in each of these areas requires an overview and a strategic guide. An MR sensor roadmap (non-recording applications) was therefore developed and made public by the Technical Committee of the IEEE Magnetics Society with the aim to provide an research and development (R&D) guide for MR sensors intended to be used by industry, government, and academia. The roadmap was developed over a three-year period and coordinated by an international effort of 22 taskforce members from ten countries and 17 organizations, including universities, research institutes, and sensor companies. In this paper, the current status of MR sensors for non-recording applications was identified by analyzing the patent and publication statistics. As a result, timescales for MR sensor development were established and critical milestones for sensor parameters were extracted in order to gain insight into potential MR sensor applications (non-recording). Five application areas were identified, and five MR sensor roadmaps were established. These include biomedical applications, flexible electronics, position sensing and human-computer interactions, non-destructive evaluation and monitoring, and navigation and transportation. Each roadmap was analyzed using a logistic growth model, and new opportunities were predicted based on the extrapolated curve, forecast milestones, and professional judgment of the taskforce members. This paper provides a framework for MR sensor technology (non-recording applications) to be used for public and private R&D planning, in order to provide guidance into likely MR sensor applications, products, and services expected in the next 15 years and beyond.

5 January 2005 in Chemical Communications
Verified
Journal Article
Closed access
PDF file
JCJia-Yaw Chang
Jia-Yaw Chang
HWHuimeng Wu
Huimeng Wu
HCHui Chen
Hui Chen
YLYong-Chien Ling
Yong-Chien Ling
WTWeihong Tan
Weihong Tan
The design and formation of a linear assembly of gold nanorods using a biomolecular recognition system are described. Anti-mouse IgG was immobilized on the {111} end faces of gold nanorods through a thioctic acid containing a terminal carboxyl group. The biofunctionalized nanorods can be assembled with the desired length using mouse IgG for biorecognition and binding. The gold nanorods can be assembled to extended nanorod chains, which can be as long as 3 µm. These assembled nanostructures may be used as the precursors for future nanodevices.

1 February 2019 in Journal of the Taiwan Institute of Chemical Engineers
Verified
Journal Article
Closed access
KDKhalilalrahman Dehvari
Khalilalrahman Dehvari
KLKai Yi Liu
Kai Yi Liu
PTPo-Jen Tseng
Po-Jen Tseng
GGGangaraju Gedda
Gangaraju Gedda
WGWubshet Mekonnen Girma
Wubshet Mekonnen Girma
JCJia-Yaw Chang
Jia-Yaw Chang

29 June 2017 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
WGWubshet Mekonnen Girma
Wubshet Mekonnen Girma
Mochamad Zakki FahmiMochamad Zakki Fahmi
Mochamad Zakki Fahmi
APAdi Permadi
Adi Permadi
Mulu Alemayehu AbateMulu Alemayehu Abate
Mulu Alemayehu Abate
JCJia-Yaw Chang
Jia-Yaw Chang
In this review, we discuss recent advances of I–III–VI QDs with a major focus on synthesis and biomedical applications; advantages include low toxicity and fluorescent tuning in the biological window.