Yi-Pin Lin

Prof. Yi-Pin Lin


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
KCKuo Chien-Yuan
Kuo Chien-Yuan
RWRong-Jing Wang
Rong-Jing Wang
YLYi-Pin Lin
Yi-Pin Lin
Chi-Ming LaiChi-Ming Lai
Chi-Ming Lai
We are investigating how to use urban design approaches to conduct the layout and basic design of newly-built high-rise buildings to reduce wind obstruction and create effective urban ventilation. Few studies have addressed this issue. This study analyzes the effects of high-rise building on pedestrian-level wind in downstream street canyons based on wind tunnel test results, and examines the suitability of an urban design specification. The height (H) of high-rise buildings and the airflow passage width (S) between adjacent high-rise buildings are key control factors for this issue; H/D = 3 and S/D = 1.125 are critical parameters and recommended values (D is the height of the downstream street blocks).

23 June 2019 in Energies
Verified
Journal Article
Open access
PDF file
Sung-Chin ChungSung-Chin Chung
Sung-Chin Chung
YLYi-Pin Lin
Yi-Pin Lin
Chun YangChun Yang
Chun Yang
Chi-Ming LaiChi-Ming Lai
Chi-Ming Lai
Using computational fluid dynamics (CFD), this study explores the effect of a different number of awning windows and their installation locations on the airflow patterns and air contaminant distributions in restrooms in K-12 (for kindergarten to 12th grade) public schools in Taiwan. A representative restroom configuration with dimensions of 10.65 m × 9.2 m × 3.2 m (height) was selected as the investigated object. Based on the façade design feasibility, seven possible awning window configurations were considered. The results indicate that an adequate number of windows and appropriate installation locations are required to ensure the natural ventilation effectiveness of awning windows. The recommended installation configuration is provided.

24 January 2022 in Buildings
Verified
Journal Article
Open access
PDF file
CCChing-Mei Chen
Ching-Mei Chen
YLYi-Pin Lin
Yi-Pin Lin
Sung-Chin ChungSung-Chin Chung
Sung-Chin Chung
Chi-Ming LaiChi-Ming Lai
Chi-Ming Lai
With ridge vents that are commonly used in building ventilation applications as the research object, this study analyzed how design parameters affect the efficiency of thermal buoyancy-driven ventilation induced by ridge vents through computational fluid dynamics (CFD). The design parameters of ridge vents include the width S, height H, and eave overhang E. In consideration of engineering practices, the parameter ranges were set as follows: S = 1.2, 1.8, 2.4, and 3 m; H = 0.3, 0.6, 0.9, and 1.2 m; and E = 0, 0.3, and 0.6 m. The results show that when a ridge vent is under buoyancy-driven ventilation, the height H serves as the dominant design parameter. Correlation equations of the induced ventilation rates with the relevant ridge vent design parameters are provided.

6 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
YLYi-Pin Lin
Yi-Pin Lin
In this study, the influence of architectural design parameters (the exterior window area, the wall height at a corridor-side, and the door gap of a toilet unit) on the airflow patterns and malodorous volatile substance (acetic acid) distributions within toilet units were investigated via computational fluid dynamics (CFD), with the restrooms in K–12 public schools (kindergarten through grade 12) of Taiwan as research objects. The results show that when there is a 2 m/s north wind in winter, all the cases exceed the required 12 air changes per hour (ACH), and most are above 43.75 ACH. When there is a 0.5 m/s south wind in summer, nearly half of the cases fail to reach 12 ACH. Maintaining an adequate natural ventilation rate and an acceptable level of odor pollution through passive design and architectural design is difficult. Thinking about how to improve the ventilation efficiency of toilet units with the aid of simple, appropriate, and energy-saving mechanical ventilation approaches is necessary.

11 May 2018 in Energies
Verified
Journal Article
Open access
PDF file
YLYi-Pin Lin
Yi-Pin Lin
CIChiemi Iba
Chiemi Iba
Chi-Ming LaiChi-Ming Lai
Chi-Ming Lai
This study explores the effect of different numbers of wall-mounted vent caps and their installation locations on the indoor air environment in residential kitchens, for which limited information is available. Wind tunnel tests were performed to study the induced ventilation rates of a vent cap, and the impact of vent caps on the natural ventilation efficiency in residential kitchens was examined using computational fluid dynamics (CFD) numerical simulations. The results were then applied to determine the appropriate quantity of vent caps and their proper installation location. The wind tunnel test results indicated that outdoor winds with speeds of 0–6 m/s that flow parallel to the wall with a vent cap induce indoor air to exit through the cap with ventilation rates of 0–20 m3/h; when the wind blows perpendicular to the wall, outdoor air with 0–31.9 m3/h flows indoors. CFD numerical simulations showed that the installation of kitchen vent caps can reduce the average carbon monoxide concentration in the cook’s breathing zone. A sufficient quantity of vent caps and the proper installation location are required to ensure the natural ventilation effectiveness of wall-mounted vent caps.

6 June 2019 in Energies
Verified
Journal Article
Open access
PDF file
HSH.M. Shih
H.M. Shih
YLYi-Pin Lin
Yi-Pin Lin
LLL.P. Lin
L.P. Lin
Chi-Ming LaiChi-Ming Lai
Chi-Ming Lai
In this study, a heat management module containing a microencapsulated phase change material (mPCM) was fabricated from mPCM (core material: paraffin; melting temperature: 37 °C) and aluminum honeycomb structures (8 mm core cell). The aluminum honeycomb functioned both as structural support and as a heat transfer channel. The thermal management performance of the proposed module under constant-temperature boundary conditions was investigated experimentally. The thermal protection period of the module decreased as the Stefan number increased; however, increasing the subcooling factor could effectively enhance the thermal protection performance. When the cold-wall temperature TC was fixed at 17 °C and the initial hot wall temperature was 47–67 °C, the heat dissipation of the module was complete 140 min after the hot-wall heat supply was stopped. The time required to complete the heat dissipation increased to 280 min when TC increased to 27 °C.