Chiemi Iba

Dr. Chiemi Iba

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Building and Environment
Verified
Journal Article
Closed access
MNMakiko Nakajima
Makiko Nakajima
SHShuichi Hokoi
Shuichi Hokoi
DODaisuke Ogura
Daisuke Ogura
CIChiemi Iba
Chiemi Iba

4 June 2021 in Energies
Verified
Journal Article
Open access
PDF file
KIKazuki Ishikawa
Kazuki Ishikawa
CIChiemi Iba
Chiemi Iba
DODaisuke Ogura
Daisuke Ogura
SHShuichi Hokoi
Shuichi Hokoi
MYMisao Yokoyama
Misao Yokoyama
Several methods for appropriate control of the hygrothermal environment in museums to prevent the deterioration of cultural artifacts were presented in previous studies. However, few detailed hygrothermal simulation models have been used considering the hygrothermal performance of building components and airflow through gaps. Furthermore, hygrothermal properties of a type of storage facility with buffer spaces prevailing in Japan have not been quantitatively evaluated. The objectives of this study were to develop a detailed numerical model of a museum storage room with buffer spaces exhibiting high humidity during summer and to quantitatively evaluate the potential factors causing it; the inflow of humid outdoor air and indirect cooling caused by the air-conditioning system of a surrounding room. We analyzed the simulated temperature and humidity for various cases in which each influencing factor was suppressed. The humidity was reduced when the exhaust fan for the surrounding rooms was stopped or the windows were made airtight, but it hardly changed when the cooling ducts and the reinforced concrete beams were insulated. Thus, the high humidity in the room was attributed to the inflow of humid outdoor air accelerated by the ventilation of surrounding rooms. Although indirect cooling had a small impact on high humidity, its impact on energy loss could still be significant.

11 May 2018 in Energies
Verified
Journal Article
Open access
PDF file
YLYi-Pin Lin
Yi-Pin Lin
CIChiemi Iba
Chiemi Iba
Chi-Ming LaiChi-Ming Lai
Chi-Ming Lai
This study explores the effect of different numbers of wall-mounted vent caps and their installation locations on the indoor air environment in residential kitchens, for which limited information is available. Wind tunnel tests were performed to study the induced ventilation rates of a vent cap, and the impact of vent caps on the natural ventilation efficiency in residential kitchens was examined using computational fluid dynamics (CFD) numerical simulations. The results were then applied to determine the appropriate quantity of vent caps and their proper installation location. The wind tunnel test results indicated that outdoor winds with speeds of 0–6 m/s that flow parallel to the wall with a vent cap induce indoor air to exit through the cap with ventilation rates of 0–20 m3/h; when the wind blows perpendicular to the wall, outdoor air with 0–31.9 m3/h flows indoors. CFD numerical simulations showed that the installation of kitchen vent caps can reduce the average carbon monoxide concentration in the cook’s breathing zone. A sufficient quantity of vent caps and the proper installation location are required to ensure the natural ventilation effectiveness of wall-mounted vent caps.

5 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
CIChiemi Iba
Chiemi Iba
SHShuichi Hokoi
Shuichi Hokoi
Climate change is an important issue that affects energy consumption, causes health problems, such as heat stroke, and requires urgent countermeasures. Serious health problems, including cardiac arrest, often occur in winter in traditional residences in Japan. Cooling-heating energy is required to maintain a healthy thermal environment. Although energy efficiency standards for buildings have been introduced worldwide to reduce energy consumption and various passive energy-saving methods are being investigated, traditional residences still face difficulties in conducting renovations because of various restrictions, such as the conservation of historical or aesthetic values. In this study, these issues and their appropriate countermeasures were investigated for a traditional townhouse in Kyoto, Japan, “Kyo-machiya” (including its new form “Heisei-no-Kyo-machiya”). The potential of reducing heating and cooling loads was examined by conducting numerical analysis considering residents’ lifestyles. Field surveys of the indoor environment were conducted in both summer and winter. It was revealed that by optimizing the times and positions of opening and closing the windows and indoor partitions, the indoor air flow could be adjusted from both thermal comfort (cooling in summer) and discomfort (cold drafts in winter) perspectives, leading to improving the indoor environment without using energy.

24 April 2018 in Energies
Verified
Journal Article
Open access
PDF file
CIChiemi Iba
Chiemi Iba
STShun Takano
Shun Takano
SHShuichi Hokoi
Shuichi Hokoi
Concerns about resource depletion have prompted several countries to promote the usage of renewable energy, such as underground heat. In Japan, underground heat-pump technology has begun to be utilized in large-scale office buildings; however, several economic problems are observed to still exist, such as high initial costs that include drilling requirements. Further, most of the traditional dwellings “Kyo-machiya” in Kyoto, Japan have a shallow well. This study intends to propose an effective ground-source heat-pump system using the well water from a “Kyo-machiya” home that does not contain any drilling works. In previous research, it was depicted that the well-water temperature decreases as the heat pump (HP) is operated and that the heat extraction efficiency steadily becomes lower. In this study, an experiment is conducted to improve efficiency using a drainage pump. Based on the experimental results, the effect of efficiency improvement and the increase in the electric power consumption of the drainage pump are examined. It is indicated that short-time drainage could help to improve efficiency without consuming excessive energy. Thus, continuous use of the heat pump becomes possible.

18 October 2023 in Building and Environment
Verified
Journal Article
Closed access
HLHan Liu
Han Liu
DODaisuke Ogura
Daisuke Ogura
SHShuichi Hokoi
Shuichi Hokoi
CIChiemi Iba
Chiemi Iba