Sudi Patel

Dr. Sudi Patel

Specialty Eye Hospital "Svjetlost", Zagreb, Croatia

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Contact Lens and Anterior Eye
Verified
Journal Article
Closed access
Sudi PatelSudi Patel
Sudi Patel
LTLarysa Tutchenko
Larysa Tutchenko

1 July 2021 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
Sudi PatelSudi Patel
Sudi Patel
LTLarysa Tutchenko
Larysa Tutchenko
Recent evidence indicates that the corneal back surface astigmatism (CBSA) contributes to the refractive state of the eye in cataract surgery, especially with the implantation of toric intraocular lenses. But this has been met with some scepticism. A review of key studies performed over the past three decades shows that the mean CBSA power ranges from 0.18(± 0.16)D to 1.04(± 0.20)D. The clinical assessment of CBSA is problematic. There is poor agreement between the current automated systems for assessment of CBSA and it is assumed that these systems directly measure the CBSA. But CBSA cannot be measured directly in vivo. A historical review of methods used to quantify the curvature of the posterior corneal surface reveals that CBSA estimated by current systems is based on values for corneal front surface astigmatism, corneal refractive index, central corneal thickness, corneal thickness at peripheral locations and the exact distance between the corneal apex and each one of these peripheral locations. Doubts and errors in these values, coupled with the precise details of the algorithm incorporated to estimate CBSA, are the likely sources of the lack of agreement between current systems. These systematic errors cloud the assessment of CBSA. Mean CBSA may be low, but it varies from case to case. There is a clear need for a realistic, practical procedure for clinicians to independently calibrate systems for estimating CBSA. This would help to reduce uncertainty and the discrepancies between instruments designed to measure the same parameter.

10 May 2022 in International Ophthalmology
Verified
Journal Article
Closed access
PDF file
FGFanka Gilevska
Fanka Gilevska
BKBiljana Kostovska
Biljana Kostovska
IOIlir Osmani
Ilir Osmani
ABAlma Biscevic
Alma Biscevic
SSSmiljka Popovic Suic
Smiljka Popovic Suic
Sudi PatelSudi Patel
Sudi Patel

1 October 1994 in Acta Ophthalmologica
Verified
Journal Article
Closed access
PDF file
Sudi PatelSudi Patel
Sudi Patel
JMJ. Marshall
J. Marshall
FFF. W. Fitzke
F. W. Fitzke
DGD. S. Gartry
D. S. Gartry

16 October 2021 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
MBMaja Bohač
Maja Bohač
ABAlma Biscevic
Alma Biscevic
IGIvan Gabric
Ivan Gabric
KGKresimir Gabric
Kresimir Gabric
VSVioleta Shijakova
Violeta Shijakova
Sudi PatelSudi Patel
Sudi Patel

1 June 2020 in Contact Lens and Anterior Eye
Verified
Journal Article
Closed access
EKEwa Mrukwa Kominek
Ewa Mrukwa Kominek
MSMonika Sarnat-Kucharczyk
Monika Sarnat-Kucharczyk
Sudi PatelSudi Patel
Sudi Patel