Fanka Gilevska

Dr. Fanka Gilevska

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Acta Informatica Medica
Verified
Journal Article
Open access
SGSenad Grisevic
Senad Grisevic
FGFanka Gilevska
Fanka Gilevska
ABAlma Biscevic
Alma Biscevic
MPMelisa Pjano
Melisa Pjano
MBMaja Bohac
Maja Bohac
APAjla Pidro
Ajla Pidro
Keratoconus is described as a degenerative bilateral, progressive, noninflammatory corneal disorder characterized by ectasia, thinning, and increased curvature. Keratoconus progression classification 1 year after performed crosslinking method in this study is based on the ABCD keratoconus grading system. To evaluate the possible keratoconus progression one year after performed a crosslinking (CXL) method based on the ABCD keratoconus grading system. Methods: Seventeen keratoconus patients (22 eyes) were included in this prospective study. CXL procedure was performed using the standard Dresden protocol at Eye Clinic Svjetlost Sarajevo with the inclusion period from January 2017 to January 2018. Twelve patients had monocular, and 5 patients had binocular treatments with follow up of 12 months. Preoperative and postoperative stages were compared using the ABCD keratoconus grading system measured on rotating Scheimpflug corneal tomography-based machine - Pentacam (Pentacam HR, Oculus Optikgeräte GmbH, Wetzlar, Germany). Out of 22 eyes, one eye had keratoconus stage I-II, 6 eyes had stage II, 4 eyes had stage III, and 9 eyes had stage III-IV. There was no statistically significant gradient change of keratoconus in comparison to one month after the surgery, p>0.05. There was no progression of the gradient when comparing to the preoperative stage. Corneal cross-linking could effectively stabilize the progression of keratoconus, as assessed by key corneal topographic parameters. Analyzing the trend of stage change in 12 months follow up after the crosslinking procedure of keratoconus patients there was no progression of a gradient in comparison to the preoperative stage. According to our results, we can conclude that CXL is a safe and effective procedure in treating keratoconus.

10 May 2022 in International Ophthalmology
Verified
Journal Article
Closed access
PDF file
FGFanka Gilevska
Fanka Gilevska
BKBiljana Kostovska
Biljana Kostovska
IOIlir Osmani
Ilir Osmani
ABAlma Biscevic
Alma Biscevic
SSSmiljka Popovic Suic
Smiljka Popovic Suic
Sudi PatelSudi Patel
Sudi Patel

22 September 2019 in Medicinski Glasnik
Verified
Journal Article
Closed access
SGSenad Grišević
Senad Grišević
FGFanka Gilevska
Fanka Gilevska
ABAlma Biscevic
Alma Biscevic
MAMelisa Ahmedbegović-Pjano
Melisa Ahmedbegović-Pjano
APAjla Pidro
Ajla Pidro
MBMaja Bohač
Maja Bohač
Aim To correlate the maximum anterior sagittal curvature (Kmax) changes and uncorrected (UDVA) and corrected distance visual acuity (CDVA) in keratoconus patients after the cross-linking (CXL) procedure. MethodsForty-four eyes of 34 patients with keratoconus were analysed after the standard Dresden protocol CXL procedure had been performed. All patients underwent complete preoperative examination with a follow-up of 12 months with focus on UDVA, CDVA and Oculus Pentacam (Scheimpflug technology) analysis. We analysed and correlated K max changes in the postoperative period of 12 months together with visual acuity changes. Results Visual acuity improved significantly in the first 3 months after the procedure and even more significantly until the end of the first year. Even K max is the most relevant and most followed parameter for progression and regression of keratoconus, its lowering was not directly correlated with the visual acuity improvement (both uncorrected and corrected) in the first 6 months after corneal CXL procedure. K max was changed significantly in the period of 12 months post cross linking, but not in the first 6 months. ConclusionCorneal CXL should be considered as a procedure not just for corneal stiffening and stabilization, but also for visual acuity improvement in keratoconus patients.

22 April 2021 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
FGFanka Gilevska
Fanka Gilevska
ABAlma Biscevic
Alma Biscevic
SSSmiljka Popovic Suic
Smiljka Popovic Suic
MBMaja Bohač
Maja Bohač
Sudi PatelSudi Patel
Sudi Patel

1 December 2024 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
LTLarysa Tutchenko
Larysa Tutchenko
Sudi PatelSudi Patel
Sudi Patel
MSMykhailo Skovron
Mykhailo Skovron
OVOleksiy V Voytsekhivskyy
Oleksiy V Voytsekhivskyy
FGFanka Gilevska
Fanka Gilevska
Purpose: To explore the significance of changes in anterior chamber depth (ΔACD) and astigmatism between 4 and 8 weeks following uneventful phacoemulsification. Patients and Methods: Anterior chamber depth (ACD, mm), autorefractometry and subjective refraction were monitored in pseudophakic eyes implanted with non-toric IOLs (group 1, SA60AT, n=36; group 2, SN60WF, n=34; group 3, ICBOO, n=16) and phakic control group (n=30, group 4a, for ACD and autorefractometry) over four weeks. Changes in subjective refractions were compared with repeatability in normal phakic eyes (n=30, group 4b). Results: Reporting key results (p< 0.01), mean (±sd 95% CI) ΔACD values (ACD at start minus ACD at four weeks) were +0.02 (± 0.37, − 0.16 to 0.08), +0.22 (± 0.51,0.05 to 0.39), − 0.33 (± 0.51, − 0.58 to − 0.08), − 0.02 (± 0.07, − 0.04 to 0.01) in groups 1– 4a respectively. Differences were significant (1-way ANOVA, F=7.02). Pooling data from the pseudophakic eyes (n=86) induced astigmatism (IA) by autorefractometry was significantly greater in comparison with group 4a [− 0.78D (± 0.67, − 0.92 to − 0.64) and − 0.19D (± 0.16, − 0.25 to - 0.13)]. IA power correlated with the initial power of refractive astigmatism at 4 weeks (A), [IA = 0.36A− 0.30 (r2=0.207) and IA = 0.39A− 0.29 (r2=0.232) by autorefractometry and subjective refraction, respectively]. In groups 1– 3, vector analysis revealed i) the change in refraction in over 55% of eyes was beyond the 95% confidence interval limits observed in groups 4a and 4b, ii) some significant associations between changes in vectors describing astigmatism with ΔACD and IOL labelled power. Conclusion: Changes in ACD and refraction still occur four weeks after unremarkable phacoemulsification and the inter-relationship depends on IOL design/type. Other factors, such as tilt or dislocation of the IOL along the X-Y axes parallel to Listing’s plane, accompanying changes in ACD are expected to affect the postop astigmatism.

Verified
Journal Article
Open access
PDF file
Snježana KaštelanSnježana Kaštelan
Snježana Kaštelan
FGFanka Gilevska
Fanka Gilevska
Zora TomićZora Tomić
Zora Tomić
JŽJosipa Živko
Josipa Živko
TNTamara Nikuševa-Martić
Tamara Nikuševa-Martić
Ocular melanomas, comprising uveal melanoma (UM) and conjunctival melanoma (CoM), represent the most common primary intraocular and ocular surface malignancies in adults. Although rare compared with cutaneous melanoma, they exhibit unique molecular landscapes that provide critical opportunities for biomarker-driven precision medicine. In UM, recurrent mutations in GNAQ and GNA11, together with alterations in BAP1, SF3B1, and EIF1AX, have emerged as key prognostic biomarkers that stratify metastatic risk and guide surveillance strategies. Conversely, in CoM, the mutational spectrum overlaps with cutaneous melanoma, with frequent alterations in BRAF, NRAS, NF1, and KIT, offering actionable targets for personalised treatment. Beyond genomics, epigenetic signatures, microRNAs, and protein-based markers provide further insights into tumour progression, microenvironmental remodelling, and immune evasion. In parallel, liquid biopsy has emerged as a minimally invasive approach for real-time disease monitoring. Analyses of circulating tumour DNA (ctDNA), circulating tumour cells (CTCs), and exosome-derived microRNAs demonstrate increasing potential for early detection of minimal residual disease, prognostic assessment, and evaluation of treatment response. However, the clinical integration of these biomarkers remains limited by tumour heterogeneity, technical variability, and the lack of unified translational frameworks. This review synthesises current knowledge of molecular and liquid biopsy biomarkers in ocular melanoma, highlighting their relevance for diagnosis, prognosis, and treatment personalisation. The integration of established tissue-based molecular markers with novel liquid biopsy technologies will enable a unique framework for biomarker-guided precision oncology and risk-adapted surveillance in uveal and conjunctival melanoma, offering insight into strategies for early detection, therapeutic monitoring, and personalised clinical management.