Pete Culmer

Dr. Pete Culmer

School of Mechanical Engineering, University of Leeds, Leeds, UK
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2017 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
EREllen Roche
Ellen Roche
MHMarkus A. Horvath
Markus A. Horvath
IWIsaac Wamala
Isaac Wamala
AAAli Alazmani
Ali Alazmani
SSSang-Eun Song
Sang-Eun Song
CWConor J. Walsh
Conor J. Walsh
A soft robotic sleeve modeled on the structure of the human heart assists cardiovascular function in an ex vivo and in vivo porcine model of heart failure.

24 August 2016 in Sensors
Verified
Journal Article
Open access
PDF file
HWHongbo Wang
Hongbo Wang
Gregory de BoerGregory de Boer
Gregory de Boer
JKJunwai Kow
Junwai Kow
AAAli Alazmani
Ali Alazmani
MGMazdak Ghajari
Mazdak Ghajari
PCPete Culmer
Pete Culmer
Tactile sensors are essential if robots are to safely interact with the external world and to dexterously manipulate objects. Current tactile sensors have limitations restricting their use, notably being too fragile or having limited performance. Magnetic field-based soft tactile sensors offer a potential improvement, being durable, low cost, accurate and high bandwidth, but they are relatively undeveloped because of the complexities involved in design and calibration. This paper presents a general design methodology for magnetic field-based three-axis soft tactile sensors, enabling researchers to easily develop specific tactile sensors for a variety of applications. All aspects (design, fabrication, calibration and evaluation) of the development of tri-axis soft tactile sensors are presented and discussed. A moving least square approach is used to decouple and convert the magnetic field signal to force output to eliminate non-linearity and cross-talk effects. A case study of a tactile sensor prototype, MagOne, was developed. This achieved a resolution of 1.42 mN in normal force measurement (0.71 mN in shear force), good output repeatability and has a maximum hysteresis error of 3.4%. These results outperform comparable sensors reported previously, highlighting the efficacy of our methodology for sensor design.

7 June 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HWHongbo Wang
Hongbo Wang
DJDominic Jones
Dominic Jones
Gregory de BoerGregory de Boer
Gregory de Boer
JKJunwai Kow
Junwai Kow
Lucia BeccaiLucia Beccai
Lucia Beccai
PCPete Culmer
Pete Culmer
Tactile sensors are essential for robotic systems to safely and effectively interact with the environment and humans. In particular, tri-axis tactile sensors are crucial for dexterous robotic manipulations by providing shear force, slip or contact angle information. The Soft Inductive Tactile Sensor (SITS) is a new type of tactile sensor that measures inductance variations caused by eddy-current effect. In this paper, we present a soft tri-axis tactile sensor using the configuration of four planar coils and a single conductive film with hyperelastic material in between them. The working principle is explained and design methods are outlined. A 3D finite element model was developed to characterize the tri-axis SITS and to optimize the target design through parameter study. Prototypes were fabricated, characterized and calibrated, and a force measurement resolution of 0.3 mN is achieved in each axis. Demonstrations show that the sensor can clearly measure light touch (a few mN normal force) and shear force pulses (10 to 30 mN) produced by a serrated leaf when it is moved across the sensor surface. The presented sensor is low cost, high performance, robust, durable, and easily customizable for a variety of robotic and healthcare applications.

27 December 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
LWLefan Wang
Lefan Wang
DJDominic Jones
Dominic Jones
GCGraham J. Chapman
Graham J. Chapman
HSHeidi J. Siddle
Heidi J. Siddle
DRDavid A. Russell
David A. Russell
PCPete Culmer
Pete Culmer
Diabetes is highly prevalent throughout the world and imposes a high economic cost on countries at all income levels. Foot ulceration is one devastating consequence of diabetes, which can lead to amputation and mortality. Clinical assessment of diabetic foot ulcer (DFU) is currently subjective and limited, impeding effective diagnosis, treatment and prevention. Studies have shown that pressure and shear stress at the plantar surface of the foot plays an important role in the development of DFUs. Quantification of these could provide an improved means of assessment of the risk of developing DFUs. However, commercially-available sensing technology can only measure plantar pressures, neglecting shear stresses and thus limiting their clinical utility. Research into new sensor systems which can measure both plantar pressure and shear stresses are thus critical. Our aim in this paper is to provide the reader with an overview of recent advances in plantar pressure and stress sensing and offer insights into future needs in this critical area of healthcare. Firstly, we use current clinical understanding as the basis to define requirements for wearable sensor systems capable of assessing DFU. Secondly, we review the fundamental sensing technologies employed in this field and investigate the capabilities of the resultant wearable systems, including both commercial and research-grade equipment. Finally, we discuss research trends, ongoing challenges and future opportunities for improved sensing technologies to monitor plantar loading in the diabetic foot.

1 March 2018 in Sensors and Actuators A: Physical
Verified
Journal Article
Open access
HWHongbo Wang
Hongbo Wang
JKJunwai Kow
Junwai Kow
NRNicholas Raske
Nicholas Raske
Gregory de BoerGregory de Boer
Gregory de Boer
MGMazdak Ghajari
Mazdak Ghajari
PCPeter Culmer
Peter Culmer

1 February 2016 in Medical Engineering & Physics
Verified
Journal Article
Open access
AAAli Alazmani
Ali Alazmani
AHA. Hood
A. Hood
DJD. Jayne
D. Jayne
ANA. Neville
A. Neville
PCP. Culmer
P. Culmer
This paper presents a method of characterizing the distribution of colorectal morphometrics. It uses three-dimensional region growing and topological thinning algorithms to determine and visualize the luminal volume and centreline of the colon, respectively. Total and segmental lengths, diameters, volumes, and tortuosity angles were then quantified. The effects of body orientations on these parameters were also examined. Variations in total length were predominately due to differences in the transverse colon and sigmoid segments, and did not significantly differ between body orientations. The diameter of the proximal colon was significantly larger than the distal colon, with the largest value at the ascending and cecum segments. The volume of the transverse colon was significantly the largest, while those of the descending colon and rectum were the smallest. The prone position showed a higher frequency of high angles and consequently found to be more torturous than the supine position. This study yielded a method for complete segmental measurements of healthy colorectal anatomy and its tortuosity. The transverse and sigmoid colons were the major determinant in tortuosity and morphometrics between body orientations. Quantitative understanding of these parameters may potentially help to facilitate colonoscopy techniques, accuracy of polyp spatial distribution detection, and design of novel endoscopic devices.