Dijana Damljanovic

Dr. Dijana Damljanovic

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2021 in Aerospace
Verified
Journal Article
Open access
PDF file
DDDijana Damljanovic
Dijana Damljanovic
DVDjordje Vukovic
Djordje Vukovic
GOGoran Ocokoljić
Goran Ocokoljić
Biljana IlicBiljana Ilic
Biljana Ilic
Bosko RasuoBosko Rasuo
Bosko Rasuo
Published results for standard wind tunnel models at non-standard test conditions are quite rare and/or may not be available. It has been found that those results are a useful aid in preparations for a number of wind tunnel tests in the Military Technical Institute (VTI) in Belgrade. Test campaigns of standard models at non-standard conditions are performed to serve as an internal database for future wind tunnel tests in such environments. Those tests, that partially overlap the referenced Mach number and/or angle of attack ranges, are conducted in different VTI’s test facilities; different model sizes and support stings were used. The standard models used in static measurements in VTI, ranging from simple missile shapes and re-entry bodies to complicated airplanes, are briefly described and sample non-standard test results are given. The correlation of the test results among models and facilities has been done with references in the available ranges, and, after confirming a good agreement, it is assumed that the results are also valid in the extended ranges of conditions. These results may be useful for researchers in other wind tunnel facilities and for those who handle CFD tools.

1 January 2020 in FME Transactions
Verified
Journal Article
Open access
PDF file
DDDijana Damljanovic
Dijana Damljanovic
ĐVĐorđe Vuković
Đorđe Vuković
GOGoran Ocokoljić
Goran Ocokoljić
Bosko RasuoBosko Rasuo
Bosko Rasuo
AGARD-B is a widely-used configuration of a standard wind tunnel model. Beside its originally intended application for correlation of data from supersonic wind tunnel facilities, it was tested in a wide range of Mach numbers and, more recently, used for assessment of wall interference effects, validation of computational fluid dynamics codes and validation of new model production technologies. The researchers and wind tunnel test engineers would, naturally, like to know the "true" aerodynamic characteristics of this model, for comparison with their own work. Obviously, such data do not exist, but an estimate can be made of the dispersion of test results from various sources and of the probable "mean" values of the aerodynamic coefficients. To this end, comparable transonic test results for the AGARD-B model at Mach numbers 0.77, Mach 1.0 and Mach 1.17 from six wind tunnels were analyzed and average values and dispersions of the aerodynamic coefficients were computed.

1 January 2014 in FME Transactions
Verified
Journal Article
Open access
PDF file
GOGoran Ocokoljić
Goran Ocokoljić
DDDijana Damljanovic
Dijana Damljanovic
Bosko RasuoBosko Rasuo
Bosko Rasuo
JIJovan Isaković
Jovan Isaković
A necessity to test a standard model testing for establishing confidence in the wind-tunnel flow quality and the validity of the test-data has been recognized in the Experimental Aerodynamics Laboratory of the Military Technical Institute (VTI) in Belgrade. A new-implemented procedure for data quality assurance has been applied to the standard AGARD-B model testing in the VTI's large-subsonic wind-tunnel. Test-data obtained at Mach number 0.4 have been analized and correlated with those of the physically same model performed in the Canadian NAE (today operates as IAR) 5ft trisonic wind-tunnel and the T-38 trisonic wind-tunnel of VTI. Within-facility comparisons and inter-facility correlations of the standard test-data were done to certify an overall reliabilty of the subsonic facility as an initial step in the establishing the confidence prior to a forthcoming customer test.

9 February 2025 in Aerospace
Verified
Journal Article
Open access
PDF file
DDDijana Damljanovic
Dijana Damljanovic
DVDjordje Vukovic
Djordje Vukovic
GOGoran Ocokoljić
Goran Ocokoljić
Bosko RasuoBosko Rasuo
Bosko Rasuo
Recent experience has shown that test results of standard wind tunnel models under off-design conditions could be a useful aid in preparations of some nonstandard wind tunnel tests. However, reference data for such conditions do not exist, or they are scarce. Therefore, off-design transonic wind tunnel tests of the HB-2 standard models were executed in the VTI T-38 wind tunnel as a supplement to the supersonic tests of the same models under design-intent conditions, for which reference results were available. New tests were conducted so that test envelopes partially overlapped with those from available supersonic reference data. Good agreements of results with references were confirmed in the overlapped ranges, so it was assumed that, by implication, the obtained results were also valid in the transonic range of conditions, with an observation that the effects of sting diameter were much more pronounced in the transonic range than in the supersonic one. HB-2 models were tested in two sizes, using two different wind tunnel balances for each model, so that the results can be used with more confidence.

1 January 2016 in Thermal Science
Verified
Journal Article
Open access
PDF file
ĐVĐorđe S. Vuković
Đorđe S. Vuković
DDDijana Damljanovic
Dijana Damljanovic
During a supersonic run of a blowdown wind tunnel, temperature of air in the test section drops which can affect planned measurements. Adverse thermal effects include variations of the Mach and Reynolds numbers, variation of airspeed, condensation of moisture on the model, change of characteristics of the instrumentation in the model, et cetera. Available data on thermal effects on instrumentation are pertaining primarily to long-run-duration wind tunnel facilities. In order to characterize such influences on instrumentation in the models, in short-run-duration blowdown wind tunnels, temperature measurements were made in the wing-panel-balance and main-balance spaces of two wind tunnel models tested in the T-38 wind tunnel. The measurements showed that model-interior temperature in a run increased at the beginning of the run, followed by a slower drop and, at the end of the run, by a large temperature drop. Panel-force balance was affected much more than the main balance. Ways of reducing the unwelcome thermal effects by instrumentation design and test planning are discussed.

16 May 2025 in Aerospace Science and Technology
Verified
Journal Article
Closed access
MMMiodrag Milenković-Babić
Miodrag Milenković-Babić
BOBranislav Ostojić
Branislav Ostojić
BDBiljana Dovatov
Biljana Dovatov
VAVuk Antonić
Vuk Antonić
INIlija Nenadić
Ilija Nenadić
DDDijana Damljanovic
Dijana Damljanovic