Biljana Ilic

Dr. Biljana Ilic

Military Technical Institute
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2021 in Aerospace
Verified
Journal Article
Open access
PDF file
DDDijana Damljanovic
Dijana Damljanovic
DVDjordje Vukovic
Djordje Vukovic
GOGoran Ocokoljić
Goran Ocokoljić
Biljana IlicBiljana Ilic
Biljana Ilic
Bosko RasuoBosko Rasuo
Bosko Rasuo
Published results for standard wind tunnel models at non-standard test conditions are quite rare and/or may not be available. It has been found that those results are a useful aid in preparations for a number of wind tunnel tests in the Military Technical Institute (VTI) in Belgrade. Test campaigns of standard models at non-standard conditions are performed to serve as an internal database for future wind tunnel tests in such environments. Those tests, that partially overlap the referenced Mach number and/or angle of attack ranges, are conducted in different VTI’s test facilities; different model sizes and support stings were used. The standard models used in static measurements in VTI, ranging from simple missile shapes and re-entry bodies to complicated airplanes, are briefly described and sample non-standard test results are given. The correlation of the test results among models and facilities has been done with references in the available ranges, and, after confirming a good agreement, it is assumed that the results are also valid in the extended ranges of conditions. These results may be useful for researchers in other wind tunnel facilities and for those who handle CFD tools.

1 January 2017 in Measurement
Verified
Journal Article
Closed access
Biljana IlicBiljana Ilic
Biljana Ilic
MMMarko Miloš
Marko Miloš
JIJovan Isaković
Jovan Isaković

1 January 2016 in FME Transactions
Verified
Journal Article
Closed access
PDF file
Biljana IlicBiljana Ilic
Biljana Ilic
MMMarko Miloš
Marko Miloš
MMMirko Milosavljević
Mirko Milosavljević
JIJovan Isaković
Jovan Isaković
The flow parameters control in wind tunnels is an area of intense research in recent years, with the aim of improving quality and efficiency of the wind tunnel operation. In this paper, an attempt is made to contribute to a better understanding of the stagnation pressure control in supersonic blowdown-type facilities. The stagnation pressure control strategy in the VTI Belgrade T-38 wind tunnel is discussed. An improved mathematical model for a supersonic wind tunnel is suggested and applied to the T-38 facility. Comparisons of simulation and experimental data are made to demonstrate accurate prediction of the facility response in supersonic flow conditions by the mathematical model. The model is used to incorporate a modified feedforward control in the original T-38 wind tunnel control system. The actual wind tunnel tests confirm model-predicted decrease of flow stabilization time and increase of available measurement time, bringing significant improvement in the wind tunnel operation efficiency.

1 January 2019 in Scientific Technical Review
Verified
Journal Article
Closed access
PDF file
Biljana IlicBiljana Ilic
Biljana Ilic
MMMirko Milosavljević
Mirko Milosavljević
Over the last few decades, the accuracy requirements for wind tunnel testing have become much more stringent as aircraft industry strives to achieve the best performance of their products. Investments in advanced capabilities are necessary to obtain more accurate test results more efficiently, ensuring that the wind tunnels stay productive well into the future. The VTI Belgrade T-38 wind tunnel responded to these challenges by applying a hierarchical approach to design a distributed multilevel control system, a part of which is the variable-geometry nozzle positioning system, presented in this paper. It follows the hierarchy of the entire wind tunnel control system, with critical positioning loops at the field-programmable gate array (FPGA), and the user interface with real-time data analysis capability implemented on a central wind tunnel computer. In addition to more accurate positioning, the FPGA-based control system significantly improved overall operation efficiency, speed and reliability. Since the nozzle geometry uniquely determines supersonic Mach number, the improved positioning accuracy is verified in wind tunnel tests.

21 April 2022 in Advances in Mechanical Engineering
Verified
Journal Article
Open access
DVDjordje Vuković
Djordje Vuković
DDDijana Damljanović
Dijana Damljanović
GOGoran Ocokoljić
Goran Ocokoljić
Biljana IlicBiljana Ilic
Biljana Ilic
Higher than anticipated supersonic starting loads in the VTI T-38 wind tunnel were a consequence of higher than designed minimum start pressures. Initially, high starting loads limited the usefulness of the facility at high supersonic Mach numbers. Over time, it was established that several procedures and techniques had to be used cooperatively to diminish the problem. One of the techniques is the establishment of additional points of contact of the model and the support sting for the duration of the starting loads, so that a part of the aerodynamic loads is transferred to the sting through the added path, relieving the sensitive force balance. Some applications of this technique require dedicated mechanisms to operate, which was impractical for the VTI T-38 wind tunnel. To the contrary, the implementation of the idea in the VTI T-38 wind tunnel relies on using suitable inserts to make the clearance between the model and the sting such that model-sting contact is forced to occur during the start and stop phenomena, but not during the measurement phase of the test. For typical model configurations, transient starting and stopping loads can be reduced by more than 50%.

1 January 2016 in Materials Today: Proceedings
Verified
Journal Article
Closed access
Biljana IlicBiljana Ilic
Biljana Ilic
MMMirko Milosavljević
Mirko Milosavljević
JIJovan Isaković
Jovan Isaković
MMMarko Miloš
Marko Miloš