Robert Ryk Van Zyl

Robert Ryk Van Zyl

Auto-generated profile, based on publicly available information

Robert Ryk Van Zyl

F'SATI, Department of Electrical Engineering, Cape Peninsula University of Technology, Bellville, South Africa

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2015 in Space Weather
Verified
Journal Article
Open access
PDF file
EMElectdom Matandirotya
Electdom Matandirotya
PCPierre J. Cilliers
Pierre J. Cilliers
RZRobert R. Van Zyl
Robert R. Van Zyl
Geomagnetically induced currents (GIC) are a result of time variations of the geomagnetic field, which induce a geoelectric field at the Earth's surface. Geomagnetic perturbations are enhanced during adverse space weather events called geomagnetic storms. All ground-based conductor networks can be affected by GIC during such events. As a way of assessing the magnitude of GIC expected in a particular technological system, models are developed, in which the computation of the induced geoelectric field is a key step. Computation of GIC in the South African power transmission network has so far been done using a uniform Earth model and improved using a layered Earth conductivity profile. In this work we present geoelectric field results obtained by using the finite element method (FEM) and improved GIC estimates using a realistic conductivity profile, magnetic field data interpolated from two South African observatories, and a new method for estimating the network coefficients, a and b, which map the north-south and east-west electric fields to their respective GIC components. The performance of the chosen FEM model demonstrates that it is an effective tool for GIC modeling. Unlike previous engineering techniques, our method for estimating the a and b coefficients from GIC and measured magnetic field data gives results that are independent of prior knowledge of the network configuration. The GIC estimated using the a and b coefficients obtained from the proposed method compares well with the measured GIC during the late October 2003 geomagnetic storm.

29 February 2016 in Space Weather
Verified
Journal Article
Open access
PDF file
EMElectdom Matandirotya
Electdom Matandirotya
PCPierre Cilliers
Pierre Cilliers
RZRobert R Van Zyl
Robert R Van Zyl
DODavid Oyedokun
David Oyedokun
JVJean de Villiers
Jean de Villiers
Geomagnetically induced currents (GICs) in conductors connected to the Earth are driven by an electric field produced by a time‐varying magnetic field linked to magnetospheric‐ionospheric current perturbations during geomagnetic storms. The GIC measurements are traditionally done on the neutral‐to‐ground connections of power transformers. A method of inferring the characteristics of GIC in power lines using differential magnetic field measurements is presented. Measurements of the GIC in the power lines connected to a particular power transformer are valuable in the verification of the modeling of GIC in the power transmission network. The differential magnetometer method (DMM) is an indirect method used to estimate the GIC in a power line. With the DMM, low‐frequency GIC in the power line is estimated from the difference between magnetic field recordings made directly underneath the power line and at some distance away, where the magnetic field of the GIC in the transmission line has negligible effect. Results of the first application of the DMM to two selected sites of the Southern African power transmission network are presented. The results show that good quality GIC measurements are achieved through the DMM using Commercially‐Off‐The‐Shelf magnetometers.

1 August 2014
Verified
Conference Paper
Closed access
MRM Roman
M Roman
RZR R van Zyl
R R van Zyl
NPN Parus
N Parus
NMN Mahatho
N Mahatho
Power transmission using HVDC transmission technology has existed for several years. As part of the design specification for such schemes, transmission line and substation insulator selection is crucial to ensure good operational performance. Leakage current may occur on insulators due to contamination, ageing of insulation materials and aggressive weather conditions, amongst others. If not mitigated, these currents can lead to line faults which occur as flashover of the insulator and the degradation of the insulator material. Monitoring leakage current on alternating current transmission lines may be accomplished using current transformer devices. However, this cannot be used in direct current transmission lines due to static magnetic fields. Toughened glass insulators are generally preferred for HVDC schemes, but composite insulators are proving to be cost-effective alternatives. However, because of its relatively new application in HVDC schemes, little has been published relating to operational data on typical leakage current magnitudes, waveforms and consequential effects thereof. ESKOM currently operates and maintains the South African sections of the Cahora Bassa HVDC scheme. At present, the utility does not have an in-situ, non-intrusive solution for monitoring the leakage currents on this scheme. This paper presents an overview of leakage current and the options available for measuring it. In-situ and non-intrusive sensors have the benefit of being used for real time monitoring as well as for live line work.

9 October 2009 in Journal of Engineering, Design and Technology
Verified
Journal Article
Closed access
PDF file
BMBokang Patrick Motjolopane
Bokang Patrick Motjolopane
RZRobert van Zyl
Robert van Zyl
Purpose – Distributed wireless sensor networks (DWSNs) are applied in a variety of applications that can enhance the quality of human life. Batteries are the predominant source of energy in DWSNs. One of the key obstacles in the adoption of DWSNs technology is the limited lifetime of batteries in microsensors. Recharging or replacing depleted batteries can significantly increase costs in DWSNs. The purpose of this paper is to address, through a thorough review, this power challenge in DWSNs and to evaluate a 16-element equiangular spiral rectenna to harvest ambient microwave energy in real-life scenarios to supply indoor DWSNs. Design/methodology/approach – The paper focuses on the practical implementation of a rectenna that can be used in electromagnetic energy harvesting. The design and measurement of the rectenna follows a broad overview of rectenna designs reported in the literature. Findings – The paper concludes that the 16-element equiangular spiral rectenna has the potential to generate power that enables long periods of operation of the DWSNs without human intervention in the power management process, thus reducing maintenance and administration costs. Originality/value – Research into electromagnetic power harvesting is very limited in the South African context. The paper presents a concise overview of existing power harvesting techniques that will benefit novice researchers in the field of electromagnetic energy harvesting. It concludes with the performance characterisation of a spiral array rectenna.

1 October 2015 in Thin Solid Films
Verified
Journal Article
Closed access
ISI. Tadadjeu Sokeng
I. Tadadjeu Sokeng
BNBalla Diop Ngom
Balla Diop Ngom
MMMandla Msimanga
Mandla Msimanga
ZNZ.Y. Nuru
Z.Y. Nuru
LKLebogang Kotsedi
Lebogang Kotsedi
RZR.R. Van Zyl
R.R. Van Zyl

27 November 2002
Verified
Conference Paper
Closed access
RZR. Van Zyl
R. Van Zyl
WPWillem Perold
Willem Perold
RBR. Botha
R. Botha