Human locomotion is remarkably robust to environmental disturbances. Previous studies have thoroughly investigated how perturbations influence body dynamics and what recovery strategies are used to regain balance. Fewer studies have attempted to establish formal links between balance and the recovery strategies that are executed to regain stability. We hypothesized that there would be a strong relationship between the magnitude of imbalance and recovery strategy during perturbed walking. To test this hypothesis, we applied transient ground surface translations that varied in magnitude, direction and onset time while 11 healthy participants walked on a treadmill. We measured stability using integrated whole-body angular momentum (iWBAM) and recovery strategy using step placement. We found the strongest relationships between iWBAM and step placement in the frontal plane for earlier perturbation onset times in the perturbed step (R2=0.52, 0.50) and later perturbation onset times in the recovery step (R2=0.18, 0.25), while correlations were very weak in the sagittal plane (all R2≤0.13). These findings suggest that iWBAM influences step placement, particularly in the frontal plane, and that this influence is sensitive to perturbation onset time. Lastly, this investigation is accompanied by an open-source dataset to facilitate research on balance and recovery strategies in response to multifactorial ground surface perturbations, including 96 perturbation conditions spanning all combinations of three magnitudes, eight directions and four gait cycle onset times.
This study introduces a robust planning framework that utilizes a model predictive control (MPC) approach, enhanced by incorporating signal temporal logic (STL) specifications. This marks the first-ever study to apply STL-guided trajectory optimization for bipedal locomotion, specifically designed to handle both translational and orientational perturbations. Existing recovery strategies often struggle with reasoning complex task logic and evaluating locomotion robustness systematically, making them susceptible to failures caused by inappropriate recovery strategies or lack of robustness. To address these issues, we design an analytical stability metric for bipedal locomotion and quantify this metric using STL specifications, which guide the generation of recovery trajectories to achieve maximum robustness degree. To enable safe and computational-efficient crossed-leg maneuver, we design data-driven self-leg-collision constraints that are 1000 times faster than the traditional inverse-kinematics-based approach. Our framework outperforms a state-of-the-art locomotion controller, a standard MPC without STL, and a linear-temporal-logic-based planner in a high-fidelity dynamic simulation, especially in scenarios involving crossed-leg maneuvers. Additionally, the Cassie bipedal robot achieves robust performance under horizontal and orientational perturbations such as those observed in ship motions. These environments are validated in simulations and deployed on hardware. Furthermore, our proposed method demonstrates versatility on stepping stones and terrain-agnostic features on inclined terrains.
3 November 2023 in IEEE Transactions on Medical Robotics and Bionics
Performing heavy manual lifting jobs can be extremely strenuous, often resulting in high rates of injury at overloaded joints. Lower-body exoskeletons have potential to mitigate this fatigue and injury through targeted joint assistance. A variety of current wearable devices aim to provide this kind of support, but their effects on both directly and indirectly targeted joints have not been fully investigated. In this study, a powered bilateral knee exoskeleton (research device), and passive back exosuit (HeroWear Apex) were compared across 10 individuals through a battery of manual lifting tasks. Metabolic, electromyographic, and subject-reported outcome measure data were used to determine which exoskeleton provided the best assistance for each task type. It was found that the knee exoskeleton significantly reduced metabolic cost by 9.6% compared to the no-exoskeleton baseline (p<.05). Both the knee and back exoskeletons reduced activation in up to 6 of the muscles measured (out of 16). Importantly, each device primarily reduced muscle activation around the joint it targeted, not around adjacent joints. These findings suggest that exoskeletons that target the knee or lower back joint during lifting can provide significant assistance in reducing exertion.
28 February 2024 in IEEE Robotics and Automation Letters
Humans are required to maintain balance during locomotion in challenging environments, which present an even bigger challenge for individuals with balance impairments. Exoskeleton-driven balance augmentation is a promising avenue to assist users in these environments, but there has been little work in developing exoskeleton devices for these applications. In this work, we present the design, realization, and validation of an autonomous robotic hip exoskeleton with frontal and sagittal actuation. This device contains four quasi-direct drive-actuated degrees of freedom, enabling both frontal and sagittal assistance at the hip joints. The device is relatively light-weight, weighing 7.76 kg, and low-profile in the frontal plane, enabling unimpeded arm swing of the user. We found that wearing the device did not change walking kinematics, validating that the design does not inhibit the user's natural motion. We validated the exoskeleton using a bilateral bang-bang controller that successfully modulated step width and length in all cardinal and ordinal directions (all p<0.001) during steady state and perturbed walking. We also found that step modulation capability is influenced by swing leg kinematics and perturbation context. Broadly, this work presents a lightweight, autonomous, powered exoskeleton that can be used to study control approaches for balance augmentation
(1) Background: Semi-active prosthetic feet can provide adaptation in different circumstances, enabling greater function with less weight and complexity than fully powered prostheses. However, determining how to control semi-active devices is still a challenge. The dynamic mean ankle moment arm (DMAMA) provides a suitable biomechanical metric, as its simplicity matches that of a semi-active device. However, it is unknown how stiffness and locomotion modes affect DMAMA, which is necessary to create closed-loop controllers for semi-active devices. In this work, we develop a method to use only a prosthesis-embedded load sensor to measure DMAMA and classify locomotion modes, with the goal of achieving mode-dependent, closed-loop control of DMAMA using a variable-stiffness prosthesis. We study how stiffness and ground incline affect the DMAMA, and we establish the feasibility of classifying locomotion modes based exclusively on the load sensor. (2) Methods: Human subjects walked on level ground, ramps, and stairs while wearing a variable-stiffness prosthesis in low-, medium-, and high-stiffness settings. We computed DMAMA from sagittal load sensor data and prosthesis geometric measurements. We used linear mixed-effects models to determine subject-independent and subject-dependent sensitivity of DMAMA to incline and stiffness. We also used a machine learning model to classify locomotion modes using only the load sensor. (3) Results: We found a positive linear sensitivity of DMAMA to stiffness on ramps and level ground. Additionally, we found a positive linear sensitivity of DMAMA to ground slope in the low- and medium-stiffness conditions and a negative interaction effect between slope and stiffness. Considerable variability suggests that applications of DMAMA as a control input should look at the running average over several strides. To examine the efficacy of real-time DMAMA-based control systems, we used a machine learning model to classify locomotion modes using only the load sensor. The classifier achieved over 95% accuracy. (4) Conclusions: Based on these findings, DMAMA has potential for use as a closed-loop control input to adapt semi-active prostheses to different locomotion modes.