Christoph P. O. Nuesslein

Christoph P. O. Nuesslein

Auto-generated profile, based on publicly available information

Christoph P. O. Nuesslein

Exoskeleton and Prosthetic Intelligent Controls (EPIC) Lab in the Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2023 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
CNChristoph Nuesslein
Christoph Nuesslein
KBKrishan Bhakta
Krishan Bhakta
JFJoshua Fernandez
Joshua Fernandez
FDFelicia Davenport
Felicia Davenport
Jennifer LeestmaJennifer Leestma
Jennifer Leestma
AYAaron Young
Aaron Young
Performing heavy manual lifting jobs can be extremely strenuous, often resulting in high rates of injury at overloaded joints. Lower-body exoskeletons have potential to mitigate this fatigue and injury through targeted joint assistance. A variety of current wearable devices aim to provide this kind of support, but their effects on both directly and indirectly targeted joints have not been fully investigated. In this study, a powered bilateral knee exoskeleton (research device), and passive back exosuit (HeroWear Apex) were compared across 10 individuals through a battery of manual lifting tasks. Metabolic, electromyographic, and subject-reported outcome measure data were used to determine which exoskeleton provided the best assistance for each task type. It was found that the knee exoskeleton significantly reduced metabolic cost by 9.6% compared to the no-exoskeleton baseline (p<.05). Both the knee and back exoskeletons reduced activation in up to 6 of the muscles measured (out of 16). Importantly, each device primarily reduced muscle activation around the joint it targeted, not around adjacent joints. These findings suggest that exoskeletons that target the knee or lower back joint during lifting can provide significant assistance in reducing exertion.

6 March 2024 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
CNChristoph P. O. Nuesslein
Christoph P. O. Nuesslein
AYAaron J. Young
Aaron J. Young
Deep learning offers a potentially powerful alternative to hand-tuned control of active lower-limb prostheses, being capable of generating continuous joint-level assistance end-to-end. This eliminates the need for conventional task classification, state machines and mid-level control equations by collapsing the entire control problem into a deep neural network. In this letter, sensor data and conventional commanded torque from an open-source powered knee-ankle prosthesis (OSL) were collected across five locomotion modes: level ground, ramp incline/decline and stair ascent/descent. Reference commanded torques were generated using an expert-tuned finite state machine-based impedance controller for each mode and transfemoral amputee participant (N = 12). Stance phases of the output were then estimated using a temporal convolutional network (TCN), which produced mode- and user-independent knee and ankle torques with RMSE of 0.154 ± 0.06 and 0.106 ± 0.06 Nm/kg, respectively. Training the model on mode-specific data only produced significant reductions in stair descent, lowering knee and ankle RMSE by 0.06 ± 0.028 and 0.033 ± 0.008 Nm/kg respectively (p < 0.05). In addition, the TCN adapted to walking speed and slope shifts in reference commanded torque. These results demonstrate that this deep learning model not only removes the need for heuristic state machines and mode classification but can also reduce or remove the need for prosthesis assistance tuning entirely.

1 February 2026 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
RCRyan T. F. Casey
Ryan T. F. Casey
CNChristoph P. O. Nuesslein
Christoph P. O. Nuesslein
FDFelicia Davenport
Felicia Davenport
JWJason Wheeler
Jason Wheeler
AMAnirban Mazumdar
Anirban Mazumdar
AYAaron J. Young
Aaron J. Young
Objective: Real-time determination of human kinematics and kinetics could advance biomechanics research and enable valuable applications of biofeedback and generalizable exoskeleton control. This work aims to investigate a task-independent, user-independent method for obtaining precise real-time joint state estimation across lower-body joints during a wide variety of tasks. Methods: We developed a generalizable sensing approach using a suit comprised of inertial measurement units (IMUs) and pressure insoles. With the suit, we collected a dataset of 33 tasks commonly performed during construction and hazardous waste cleanup (N = 10). We then trained deep learning user-independent, task-agnostic models to estimate joint lower-body kinematics and dynamics using only worn sensor data. We likewise computed joint kinematics and dynamics analytically from sensor data to serve as a comparison tool for model results. Results: Our models achieved overall angle estimation root-mean-squared-errors (RMSE) of 6.56±.92°, 8.60±1.01°, 7.58±.89°, and 6.00±.73° compared to 13.9±.1.3°, 15.31±1.0°, 10.76±.70°, and 7.56±.48° via analytical methods at the lower back, hip, knee, and ankle, respectively. Likewise, our models achieved overall normalized moment estimation RMSEs of .207±.069 Nm/kg, .242±.044 Nm/kg, .202±.038 Nm/kg, and .193±.034 Nm/kg compared to .306±.036 Nm/kg, .407±.021 Nm/kg, 1.18 ±.022 Nm/kg, and 1.73±.071 Nm/kg via analytical methods at the lower back, hip, knee, and ankle, respectively. Conclusion: These results are comparable to other state-of-the-art wearable sensing systems, establishing deep learning as a viable sensing approach that generalizes to new users and tasks. Significance: This work shows promise for enabling accurate real-world biomechanical data collection and enhancement of biofeedback systems and wearable robot control.

1 October 2026 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
ICIan Cullen
Ian Cullen
CNChristoph Nuesslein
Christoph Nuesslein
AYAaron Young
Aaron Young
OBJECTIVE: The study seeks to determine whether a powered, cable-driven exosuit has the potential to lower the lumbar muscle activity and overall metabolic expenditure of symmetric and asymmetric lifting tasks. METHODS: A lightweight, cable-driven back exosuit, using a three-state impedance controller, was developed to provide variable assistance based on user posture. Experimental electromyography (EMG), metabolic cost, and user preference data were recorded for ten participants evaluated wearing the powered back exosuit versus the backX, a commercially available passive back support exoskeleton, and a no exo baseline. RESULTS: Both exoskeletons significantly reduced (p$< $0.05) muscle activation of certain lumbar flexor and extensor muscles when compared to a no exo condition across all conditions tested, though neither significantly reduced the metabolic cost associated with lifting. Users tended to prefer lifting with the powered device as opposed to the passive or no exo condition. CONCLUSION: Despite the increased mass of powered back support exoskeletons, these devices can reduce lumbar muscle activity to a similar degree as passive exoskeletons, and are favored by users over their passive counterparts. SIGNIFICANCE: While current powered back support devices tend to incur the cost of being heavy, rigid, and inconvenient for certain lifting postures, these results show that cable-driven powered devices may minimize these factors to the point that they are favored over the currently popular passive devices on the market.

1 January 2026 in IEEE Access
Verified
Journal Article
Open access
Jennifer LeestmaJennifer Leestma
Jennifer Leestma
SNSiddharth R. Nathella
Siddharth R. Nathella
CNChristoph P. O. Nuesslein
Christoph P. O. Nuesslein
SMSnehil Mathur
Snehil Mathur
GSGregory S. Sawicki
Gregory S. Sawicki
AYAaron J. Young
Aaron J. Young