Felicia Davenport

Felicia Davenport

Auto-generated profile, based on publicly available information

Felicia Davenport

Georgia Institute of Technology

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

3 November 2023 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
CNChristoph Nuesslein
Christoph Nuesslein
KBKrishan Bhakta
Krishan Bhakta
JFJoshua Fernandez
Joshua Fernandez
FDFelicia Davenport
Felicia Davenport
Jennifer LeestmaJennifer Leestma
Jennifer Leestma
AYAaron Young
Aaron Young
Performing heavy manual lifting jobs can be extremely strenuous, often resulting in high rates of injury at overloaded joints. Lower-body exoskeletons have potential to mitigate this fatigue and injury through targeted joint assistance. A variety of current wearable devices aim to provide this kind of support, but their effects on both directly and indirectly targeted joints have not been fully investigated. In this study, a powered bilateral knee exoskeleton (research device), and passive back exosuit (HeroWear Apex) were compared across 10 individuals through a battery of manual lifting tasks. Metabolic, electromyographic, and subject-reported outcome measure data were used to determine which exoskeleton provided the best assistance for each task type. It was found that the knee exoskeleton significantly reduced metabolic cost by 9.6% compared to the no-exoskeleton baseline (p<.05). Both the knee and back exoskeletons reduced activation in up to 6 of the muscles measured (out of 16). Importantly, each device primarily reduced muscle activation around the joint it targeted, not around adjacent joints. These findings suggest that exoskeletons that target the knee or lower back joint during lifting can provide significant assistance in reducing exertion.

3 January 2018
Verified
Conference Paper
Open access
FDFelicia Davenport
Felicia Davenport
FAFidel Amezcua
Fidel Amezcua
MSMel S. Sabella
Mel S. Sabella
ADAndrea G. Van Duzor
Andrea G. Van Duzor

1 February 2026 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
RCRyan T. F. Casey
Ryan T. F. Casey
CNChristoph P. O. Nuesslein
Christoph P. O. Nuesslein
FDFelicia Davenport
Felicia Davenport
JWJason Wheeler
Jason Wheeler
AMAnirban Mazumdar
Anirban Mazumdar
AYAaron J. Young
Aaron J. Young
Objective: Real-time determination of human kinematics and kinetics could advance biomechanics research and enable valuable applications of biofeedback and generalizable exoskeleton control. This work aims to investigate a task-independent, user-independent method for obtaining precise real-time joint state estimation across lower-body joints during a wide variety of tasks. Methods: We developed a generalizable sensing approach using a suit comprised of inertial measurement units (IMUs) and pressure insoles. With the suit, we collected a dataset of 33 tasks commonly performed during construction and hazardous waste cleanup (N = 10). We then trained deep learning user-independent, task-agnostic models to estimate joint lower-body kinematics and dynamics using only worn sensor data. We likewise computed joint kinematics and dynamics analytically from sensor data to serve as a comparison tool for model results. Results: Our models achieved overall angle estimation root-mean-squared-errors (RMSE) of 6.56±.92°, 8.60±1.01°, 7.58±.89°, and 6.00±.73° compared to 13.9±.1.3°, 15.31±1.0°, 10.76±.70°, and 7.56±.48° via analytical methods at the lower back, hip, knee, and ankle, respectively. Likewise, our models achieved overall normalized moment estimation RMSEs of .207±.069 Nm/kg, .242±.044 Nm/kg, .202±.038 Nm/kg, and .193±.034 Nm/kg compared to .306±.036 Nm/kg, .407±.021 Nm/kg, 1.18 ±.022 Nm/kg, and 1.73±.071 Nm/kg via analytical methods at the lower back, hip, knee, and ankle, respectively. Conclusion: These results are comparable to other state-of-the-art wearable sensing systems, establishing deep learning as a viable sensing approach that generalizes to new users and tasks. Significance: This work shows promise for enabling accurate real-world biomechanical data collection and enhancement of biofeedback systems and wearable robot control.

1 April 2025 in Journal of Applied Biomechanics
Verified
Journal Article
Open access
PDF file
FDFelicia R. Davenport
Felicia R. Davenport
Jennifer LeestmaJennifer Leestma
Jennifer Leestma
ASAdriana Staten
Adriana Staten
KBKrishan Bhakta
Krishan Bhakta
JFJoshua Fernandez
Joshua Fernandez
GSGregory S. Sawicki
Gregory S. Sawicki
Repetitive manual labor tasks involving twisting, bending, and lifting commonly lead to lower back and knee injuries in the workplace. To identify tasks with high injury risk, we recruited N = 9 participants to perform industry-relevant, 2-handed lifts with a 11-kg weight. These included symmetrical/asymmetrical, ascending/descending lifts that varied in start-to-end heights (knee-to-waist and waist-to-shoulder). We used a data-driven musculoskeletal model that combined force and motion data with a muscle activation-informed solver (OpenSim, CEINMS) to estimate 3-dimensional internal joint contact forces (JCFs) in the lower back (L5/S1) and knee. Symmetrical lifting resulted in larger peak JCFs than asymmetrical lifting in both the L5/S1 (+20.2% normal [P < .01], +20.3% shear [P = .001], +20.6% total [P < .01]) and the knee (+39.2% shear [P = .001]), and there were no differences in peak JCFs between ascending versus descending motions. Below-the-waist lifting generated significantly greater JCFs in the L5/S1 and knee than above-the-waist lifts (P < .01). We found a positive correlation between knee and L5/S1 peak total JCFs (R2 = .60, P < .01) across the task space, suggesting motor coordination that favors sharing of load distribution across the trunk and legs during lifting.