Shyngys Zharassov

Mr. Shyngys Zharassov

Civil Engineering, L. N. Gumilyov Eurasian National University, Nur-Sultan, Astana, Kazakhstan
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2023 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
Yelbek UtepovYelbek Utepov
Yelbek Utepov
ANAlexandr Neftissov
Alexandr Neftissov
TMTimoth Mkilima
Timoth Mkilima
AMAssel Mukhamejanova
Assel Mukhamejanova
Shyngys ZharassovShyngys Zharassov
Shyngys Zharassov
ABAndrii Biloshchytskyi
Andrii Biloshchytskyi
Improper monitoring of sewage networks may raise various issues such as overflows, pipe blockages, theft of manhole covers, leading to flooding and pollution, infrastructure damage, vehicles accidents, injury, and even death from falling into open manholes. The key objective of this research was to examine different elements and create a prototype architecture for a real-time sewer monitoring system. Implementation of the architecture involved constructing a data gathering station and experimenting with various wireless sensing devices to assess the precision of the sensors. In addition, the study sought to design a geographic information system that integrates algorithms capable of identifying sewer overflow, blocked pipes, and the presence of manhole covers. The performance of Sharp GP2Y0A41SK0F infrared, TF-Luna Benewake LiDar, TOF400 VL53L1X laser, JSN-SR04T ultrasonic distance sensors was tested in terms of their ability to monitor water level and manhole cover. Tests revealed the most favorable results in TOF400 VL53L1X at distances between 0.2 and 1.0 m (presumed distance to the manhole cover) with a standard deviation of 0.13–0.24, and in TF-Luna Benewake at distances between 1.0 and 5.0 m (presumed distance to the chamber bottom) with a standard deviation of 0.44–1.15. The deviation analysis has yielded equations that can be utilized to provide rough estimates of the accuracy levels of the aforementioned sensors, based on the measured distance. Additionally, the FC-28 analog and YL-63 infrared sensors were evaluated for detecting pipe blockages, with the YL-63 being more suitable. The outcomes of this study furnish valuable insights that can aid in achieving sustainable resolutions for issues related to sewer monitoring

21 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Yelbek UtepovYelbek Utepov
Yelbek Utepov
Aleksej AniskinAleksej Aniskin
Aleksej Aniskin
Assel TulebekovaAssel Tulebekova
Assel Tulebekova
AAAliya K. Aldungarova
Aliya K. Aldungarova
Shyngys ZharassovShyngys Zharassov
Shyngys Zharassov
Assel SarsembayevaAssel Sarsembayeva
Assel Sarsembayeva
The maturity method is deservedly considered one of the reliable indirect methods for determining the strength at the early stages of concrete curing. The main parameter in the calculation is the internal temperature of concrete that accumulates during the chemical reaction of concrete curing, while external factors such as ambient temperature and relative humidity are fallaciously omitted. In this work, the complex maturity method was developed based on ASTM C1074, accounting for the influence of ambient temperature and relative humidity and coefficients indicating their influence weight. The laboratory testing to measure the concrete strength by compression method and non-destructive sclerometer method were performed on concrete samples according to ASTM C109, GOST 22690, and GOST 10180. According to the calibration dependence of the existing and proposed methods results in comparison with the strength of cubic samples, the highest coefficient of determination R2 = 0.976 was revealed for the complex method of maturity, which indicates its reliability in contrast with sclerometer and traditional maturity methods. The determination of complex maturity allows for an evaluation of the current state of concrete strength, but also reduces the waiting time for concrete curing and increases the economic effect during construction.

29 April 2022 in Infrastructures
Verified
Journal Article
Open access
PDF file
Yelbek UtepovYelbek Utepov
Yelbek Utepov
AAAliya K. Aldungarova
Aliya K. Aldungarova
TMTimoth Mkilima
Timoth Mkilima
IPIgnacio Menéndez Pidal
Ignacio Menéndez Pidal
Assel TulebekovaAssel Tulebekova
Assel Tulebekova
AAAssem Kairatovna Abisheva
Assem Kairatovna Abisheva
This study investigated the potential influence of operating water levels and loading conditions on the slope stability of an embankment dam. Four different operating reservoir levels (normal, reduced, embankment height, and overflow) were considered in the study. Numerical modeling was used to investigate the problem in the case of the Chardara dam within the Syrdarya catchment in Kazakhstan. Based on the drawdown rates and operating conditions, minimum factor of safety values ranging from 0.56 (total failure) to 2.5 were retrieved. Furthermore, a very high correlation was observed between drawdown days, the minimum factor of safety values, the maximum factor of safety values, and pore-water pressures, with correlation coefficients ranging from 0.561 to 0.997 (strong to very strong correlation). On the other hand, the highest negative correlation of 0.997 was observed between the minimum factor of safety values and pore-water pressures. Additionally, based on the results from the analysis of variance, three reservoir operating levels (normal, embankment height, and overflow) resulted in p-values less than 0.05, indicating that the variations in the factor of safety values from the drawdown rates were statistically significant. The findings of this study demonstrated that, not only may the drawdown rate be detrimental to the embankments, but that different operating levels can also affect slope stability in different ways.

23 November 2022 in Infrastructures
Verified
Journal Article
Open access
PDF file
Yelbek UtepovYelbek Utepov
Yelbek Utepov
Assel TulebekovaAssel Tulebekova
Assel Tulebekova
AAAliya K. Aldungarova
Aliya K. Aldungarova
TMTimoth Mkilima
Timoth Mkilima
Shyngys ZharassovShyngys Zharassov
Shyngys Zharassov
ZKZhanar Kaliyeva
Zhanar Kaliyeva
Concrete strength gain can be significantly affected by the initial characteristics of the raw materials. Unfortunately, information on the potential influence of the initial water pH on concrete strength gain is still scarce. In this study, the potential effects of the initial water pH on concrete strength gain were investigated using a combination of sensors and a sclerometric test. The impact of initial pH on the strength gain process was investigated using three distinct pH values (4.0, 7.0, and 12). The primary variables examined were pH variations over time, internal temperature, and strength gain. The problem was further examined using a number of statistical techniques, including Single-way Analysis of Variance, Scheffé’s approach, and Correlation Matrixes. When the temperature data from 4.0, 7.0, and 12 pH values were put through the Analysis of Variance, a p-value of 2.4 × 10−261 was retrieved. Additionally, when the strength gain data from 4.0, 7.0, and 12 pH values were subjected to the Analysis of Variance, a p-value of 2.9 × 10−168 was retrieved. The results showed that the differences in the list data retrieved from the investigated pH values were statistically significant. Based on the results, we can state that the initial pH level in the mixing water can have noticeably varied consequences in terms of the strength gain of the concrete and should be carefully considered during the preparation process of concrete. The findings retrieved from this study provide a piece of useful information in the construction field, especially with concrete strength management.

30 September 2021 in Technobius
Verified
Journal Article
Open access
PDF file
NBNursultan Baltabekov
Nursultan Baltabekov
Shyngys ZharassovShyngys Zharassov
Shyngys Zharassov
TZTimur Zhussupov
Timur Zhussupov
Yelbek UtepovYelbek Utepov
Yelbek Utepov
The construction industry is one of the most unpredictable and human-dependent sectors of production. This is due to the large flow of information during construction, which requires clear organizational activities. Traditionally established methods of communication on construction sites require modernization. That is why the concept for practitioners "Building Description System and Construction Product Modeling" was developed in 1970. The building society supported this concept and called it "Building Information Modeling" - BIM. The new wave of digital design required a strong material and technical base, the analysis of existing documentation and the creation of design tools began. The authors of the article use the highly specialized NavisWorks software to analyze possible losses as a result of combining the existing design documentation into BIM models on the example of one of the Nur-Sultan projects. The residential complex located in Nur-Sultan was chosen as the object under study. The residential apartment building was chosen because of the scale of the project and its full implementation in the BIM system. The article makes a comparative analysis on finding the intersections on the principle of combinatorics. The section of structural and space-planning solutions is checked for intersections with the sections of heating and ventilation, water supply and sewerage, then the logic is repeated. Exceptional combinations are selected to check for conflicts (collisions).

30 March 2022 in Bulletin of the Karaganda University "Physics Series"
Verified
Journal Article
Closed access
YUYe.B. Utepov
Ye.B. Utepov
AAA. Aniskin
A. Aniskin
ATA.S. Tulebekova
A.S. Tulebekova
SAS.B. Akhazhanov
S.B. Akhazhanov
Shyngys ZharassovShyngys Zharassov
Shyngys Zharassov