Yelbek Utepov

Prof. Dr. Yelbek Utepov

L.N. Gumilyov Eurasian National University
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2024 in Heliyon
Verified
Journal Article
Open access
Yelbek UtepovYelbek Utepov
Yelbek Utepov
ANAlexandr Neftissov
Alexandr Neftissov
TMTimoth Mkilima
Timoth Mkilima
Zhanbolat ShakhmovZhanbolat Shakhmov
Zhanbolat Shakhmov
SASungat Akhazhanov
Sungat Akhazhanov
AKAigul Kenzhebekkyzy Kozhas
Aigul Kenzhebekkyzy Kozhas
Efficient sanitation system management relies on vigilant sewage surveillance to uphold environmental hygiene. The absence of robust monitoring infrastructure jeopardizes unimpeded conduit flow, leading to floods and contamination. The accumulation of harmful gases in sewer chambers, coupled with tampered lids, compounds sewer network challenges, resulting in structural damage, disruptions, and safety risks from accidents and gas inhalation. Notably, even vehicular transit is vulnerable, facing collisions due to inadequately secured manholes. The core objective of this research was to deconstruct and synthesize a prototype blueprint for a live-feed sewer monitoring framework (LSMF). This involves creating a data gathering nexus (DGN) and empirically assessing diverse wireless sensing implements (WSI) for precision. Simultaneously, a geographic information matrix (GIM) was developed with algorithms to detect sewer surges, blockages, and missing manhole covers. Three scrutinized sensors—the LiDar TF-Luna, laser TOF400 VL53L1X, and ultrasonic JSN-SR04T—were evaluated for their ability to measure water levels in sewer vaults. The results showed that the TF-Luna LiDar sensor performed favorably within the 1.0–5.0 m range, with a standard deviation of 0.44–1.15. The TOF400 laser sensor ranked second, with a more variable standard deviation of up to 104 as obstacle distance increased. In contrast, the JSN-SR04T ultrasonic sensor exhibited lower standard deviation but lacked consistency, maintaining readings of 0.22–0.23 m within the 2.0–5.0 m span. The insights from this study provide valuable guidance for sustainable solutions to sewer surveillance challenges. Moreover, employing a logarithmic function, TF-Luna Benewake exhibited reliability at approximately 84.5%, while TOF400 VL53L1X adopted an exponential equation, boasting reliability approaching approximately 89.6%. With this navigational tool, TF-Luna Benewake maintained accuracy within ±10 cm for distances ranging from 8 to 10 m, showcasing its exceptional performance.

30 June 2023 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
Yelbek UtepovYelbek Utepov
Yelbek Utepov
ANAlexandr Neftissov
Alexandr Neftissov
TMTimoth Mkilima
Timoth Mkilima
AMAssel Mukhamejanova
Assel Mukhamejanova
Shyngys ZharassovShyngys Zharassov
Shyngys Zharassov
ABAndrii Biloshchytskyi
Andrii Biloshchytskyi
Improper monitoring of sewage networks may raise various issues such as overflows, pipe blockages, theft of manhole covers, leading to flooding and pollution, infrastructure damage, vehicles accidents, injury, and even death from falling into open manholes. The key objective of this research was to examine different elements and create a prototype architecture for a real-time sewer monitoring system. Implementation of the architecture involved constructing a data gathering station and experimenting with various wireless sensing devices to assess the precision of the sensors. In addition, the study sought to design a geographic information system that integrates algorithms capable of identifying sewer overflow, blocked pipes, and the presence of manhole covers. The performance of Sharp GP2Y0A41SK0F infrared, TF-Luna Benewake LiDar, TOF400 VL53L1X laser, JSN-SR04T ultrasonic distance sensors was tested in terms of their ability to monitor water level and manhole cover. Tests revealed the most favorable results in TOF400 VL53L1X at distances between 0.2 and 1.0 m (presumed distance to the manhole cover) with a standard deviation of 0.13–0.24, and in TF-Luna Benewake at distances between 1.0 and 5.0 m (presumed distance to the chamber bottom) with a standard deviation of 0.44–1.15. The deviation analysis has yielded equations that can be utilized to provide rough estimates of the accuracy levels of the aforementioned sensors, based on the measured distance. Additionally, the FC-28 analog and YL-63 infrared sensors were evaluated for detecting pipe blockages, with the YL-63 being more suitable. The outcomes of this study furnish valuable insights that can aid in achieving sustainable resolutions for issues related to sewer monitoring

21 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Yelbek UtepovYelbek Utepov
Yelbek Utepov
Aleksej AniskinAleksej Aniskin
Aleksej Aniskin
Assel TulebekovaAssel Tulebekova
Assel Tulebekova
AAAliya K. Aldungarova
Aliya K. Aldungarova
Shyngys ZharassovShyngys Zharassov
Shyngys Zharassov
Assel SarsembayevaAssel Sarsembayeva
Assel Sarsembayeva
The maturity method is deservedly considered one of the reliable indirect methods for determining the strength at the early stages of concrete curing. The main parameter in the calculation is the internal temperature of concrete that accumulates during the chemical reaction of concrete curing, while external factors such as ambient temperature and relative humidity are fallaciously omitted. In this work, the complex maturity method was developed based on ASTM C1074, accounting for the influence of ambient temperature and relative humidity and coefficients indicating their influence weight. The laboratory testing to measure the concrete strength by compression method and non-destructive sclerometer method were performed on concrete samples according to ASTM C109, GOST 22690, and GOST 10180. According to the calibration dependence of the existing and proposed methods results in comparison with the strength of cubic samples, the highest coefficient of determination R2 = 0.976 was revealed for the complex method of maturity, which indicates its reliability in contrast with sclerometer and traditional maturity methods. The determination of complex maturity allows for an evaluation of the current state of concrete strength, but also reduces the waiting time for concrete curing and increases the economic effect during construction.

30 March 2022 in Archives of Civil Engineering
Verified
Journal Article
Open access
PDF file
Yelbek UtepovYelbek Utepov
Yelbek Utepov
ZLZbigniew Lechowicz
Zbigniew Lechowicz
Askar ZhussupbekovAskar Zhussupbekov
Askar Zhussupbekov
ZSZdzisław Skutnik
Zdzisław Skutnik
AAAliya K. Aldungarova
Aliya K. Aldungarova
TMTimoth Mkilima
Timoth Mkilima
A fast reduction of a reservoir level may result in instability of an earth dam caused by the high pore water pressures that remain relatively high in the embankment. Moreover, the dissipation of the accumulated pore water pressures is highly dependent on the permeability of the materials used for the embankment and the storage characteristics of the reservoir. Therefore, in the design of embankment dams, the stability analysis under rapid drawdown loading conditions is an important design case. In this study, the influence of different permeability rates on dam stability under different cases of rapid drawdownwas investigated using the finite element method in SEEP/W and SLOPE/W of the GeoStudio with a case of the Lugoda dam in Ndembera catchment, Tanzania. The modeling process considers the time-dependent hydraulic conditions and the transient flow conditions using different water levels during rapid drawdown for evaluation of the factor of safety. From the 1m per day drawdown rate; the lowest minimum factor of safety value (0.90) was obtained from the 10 -7 m/s material permeability of the upstream zone of the dam. It means that, at a drawdown rate of 1m per day, there is a potential for failure of the embankment if the hydraulic conductivity value will be somewhere below 10 -6 m/s.

29 April 2022 in Infrastructures
Verified
Journal Article
Open access
PDF file
Yelbek UtepovYelbek Utepov
Yelbek Utepov
AAAliya K. Aldungarova
Aliya K. Aldungarova
TMTimoth Mkilima
Timoth Mkilima
IPIgnacio Menéndez Pidal
Ignacio Menéndez Pidal
Assel TulebekovaAssel Tulebekova
Assel Tulebekova
AAAssem Kairatovna Abisheva
Assem Kairatovna Abisheva
This study investigated the potential influence of operating water levels and loading conditions on the slope stability of an embankment dam. Four different operating reservoir levels (normal, reduced, embankment height, and overflow) were considered in the study. Numerical modeling was used to investigate the problem in the case of the Chardara dam within the Syrdarya catchment in Kazakhstan. Based on the drawdown rates and operating conditions, minimum factor of safety values ranging from 0.56 (total failure) to 2.5 were retrieved. Furthermore, a very high correlation was observed between drawdown days, the minimum factor of safety values, the maximum factor of safety values, and pore-water pressures, with correlation coefficients ranging from 0.561 to 0.997 (strong to very strong correlation). On the other hand, the highest negative correlation of 0.997 was observed between the minimum factor of safety values and pore-water pressures. Additionally, based on the results from the analysis of variance, three reservoir operating levels (normal, embankment height, and overflow) resulted in p-values less than 0.05, indicating that the variations in the factor of safety values from the drawdown rates were statistically significant. The findings of this study demonstrated that, not only may the drawdown rate be detrimental to the embankments, but that different operating levels can also affect slope stability in different ways.

23 November 2022 in Infrastructures
Verified
Journal Article
Open access
PDF file
Yelbek UtepovYelbek Utepov
Yelbek Utepov
Assel TulebekovaAssel Tulebekova
Assel Tulebekova
AAAliya K. Aldungarova
Aliya K. Aldungarova
TMTimoth Mkilima
Timoth Mkilima
Shyngys ZharassovShyngys Zharassov
Shyngys Zharassov
ZKZhanar Kaliyeva
Zhanar Kaliyeva
Concrete strength gain can be significantly affected by the initial characteristics of the raw materials. Unfortunately, information on the potential influence of the initial water pH on concrete strength gain is still scarce. In this study, the potential effects of the initial water pH on concrete strength gain were investigated using a combination of sensors and a sclerometric test. The impact of initial pH on the strength gain process was investigated using three distinct pH values (4.0, 7.0, and 12). The primary variables examined were pH variations over time, internal temperature, and strength gain. The problem was further examined using a number of statistical techniques, including Single-way Analysis of Variance, Scheffé’s approach, and Correlation Matrixes. When the temperature data from 4.0, 7.0, and 12 pH values were put through the Analysis of Variance, a p-value of 2.4 × 10−261 was retrieved. Additionally, when the strength gain data from 4.0, 7.0, and 12 pH values were subjected to the Analysis of Variance, a p-value of 2.9 × 10−168 was retrieved. The results showed that the differences in the list data retrieved from the investigated pH values were statistically significant. Based on the results, we can state that the initial pH level in the mixing water can have noticeably varied consequences in terms of the strength gain of the concrete and should be carefully considered during the preparation process of concrete. The findings retrieved from this study provide a piece of useful information in the construction field, especially with concrete strength management.