Ning-Ze Zhang

Dr. Ning-Ze Zhang

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2022 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
NZNing-Ze Zhang
Ning-Ze Zhang
QXQi-Sheng Xiong
Qi-Sheng Xiong
JYJie Yao
Jie Yao
BLBo-Lun Liu
Bo-Lun Liu
MZMin Zhang
Min Zhang
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng

29 December 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
NZNing-Ze Zhang
Ning-Ze Zhang
BLBo-Lun Liu
Bo-Lun Liu
YLYi-Chao Luan
Yi-Chao Luan
MZMin Zhang
Min Zhang
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng

1 April 2022 in Ceramics International
Verified
Journal Article
Closed access
NZNing-Ze Zhang
Ning-Ze Zhang
MLMei Li
Mei Li
XDXiang Dong
Xiang Dong
KCKai Chen
Kai Chen
XCXiao-Yan Cao
Xiao-Yan Cao
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng

7 July 2021 in Materials
Verified
Journal Article
Open access
PDF file
JSJian Su
Jian Su
JWJian-Jun Wang
Jian-Jun Wang
SYS.T. Yan
S.T. Yan
MZMin Zhang
Min Zhang
Huizhi WangHuizhi Wang
Huizhi Wang
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng
Cobalt-chromium-molybdenum alloy (CoCrMo) and ceramic are the two most common materials for the femoral head in hip joint prostheses, and the acetabular liner is typically made from ultra-high molecular weight polyethylene (UHMWPE), highly cross-linked polyethylene (XLPE), or highly cross-linked polyethylene blended with Vitamin E (VEXLPE). The selection of suitable materials should consider both wear performance and cost-effectiveness. This study compared the wear rate between different friction pairs using a hip joint simulator and then recommended a suitable prosthesis based on the corresponding processing technology and cost. All wear simulations were performed in accordance with ISO 14242, using the same hip joint simulator and same test conditions. This study found that when using the same material for the femoral head, the XLPE and VEXLPE liners had a lower wear rate than the UHMWPE liners, and the wear rate of the XLPE liners increased after blending with Vitamin E (VEXLPE). There was no significant difference in the wear rate of XLPE when using a CoCrMo or ceramic head. Considering the wear rate and cost-effectiveness, a CoCrMo femoral head with an accompanying XLPE liner is recommended as the more suitable combination for hip prostheses.

25 June 2025 in Journal of Orthopaedic Translation
Verified
Journal Article
Open access
MNMao-Dan Nie
Mao-Dan Nie
BBBing-Kun Bao
Bing-Kun Bao
NZNing-Ze Zhang
Ning-Ze Zhang
RCRongshan Cheng
Rongshan Cheng
LFLing-Jie Fu
Ling-Jie Fu
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng
Intervertebral disc (IVD) herniation is a degenerative spine disease, and current treatments often result in reherniation due to iatrogenic annulus fibrosus (AF) defects. Developing effective AF repair strategies is critical to preventing reherniation and improving surgical outcomes. This study aims to develop a novel hydrogel plug to repair significant AF defects, improving surgical outcomes and reducing the risk of reherniation. Inspired by Dumbbell, a novel hydrogel plug was developed using methacrylate-grafted hyaluronic acid and 4-arm polyethylene glycol. The plug's geometry was optimized via an IVD finite element (FE) model, adjusting the bulbous end's thickness, radius, and curvature. A scanning electron microscope characterized the hydrogel's microstructure. Swelling behavior was assessed through freeze-drying and rehydration, and the mechanical properties were evaluated by compression and tensile testing. Degradation studies were performed in vitro and in vivo. The material's biocompatibility was assessed with cytotoxicity assays and subcutaneous implantation in mice. The repair efficacy of the dumbbell-shaped plug was analyzed using the lumbar spine FE model and was validated through dynamic mechanical testing. Finally, the plugs were inserted into the goat IVD injury model to compare the repair effects with the goat model for non-damaged, non-repaired, and suture-repaired conditions. The harvested samples were assessed using MRI and histological analysis, and the stability of the repair was verified through mechanical testing. The hydrogel exhibited rapid swelling, had mechanical properties similar to the natural AF, showed a stable degradation profile, and had excellent biocompatibility. For repairing a 3 mm defect, the FE simulation showed that a plug with an inner bulbous end radius of 2.25 mm, a thickness of 1.5 mm, and a curvature of 20–30° provided the most uniform stress distribution and optimal lumbar stability. The plug was successfully implanted into an ex vivo lumbar model and maintained its position after 10,000 cyclic loads. In the vivo goat model, no marked degeneration of the plug is observed on MRI after 4 weeks. Histological and immunostaining results revealed no significant inflammation, with slight vascular and fibrous tissue formation in both the plug and suture groups. The plug group demonstrated superior compressive strength compared to the suture repair and the untreated group. This study developed and tested a novel hydrogel plug system for repairing large AF defects. The hydrogel plug resulted in an AF repair with superior mechanical properties, better biocompatibility, and a more effective defect repair than traditional suturing. Given the current lack of products for repairing significant AF defects, this study developed a novel hydrogel plug system with excellent mechanical properties and biocompatibility, resulting in an effective AF repair. This implant has substantial translational potential for clinical applications in minimally invasive spinal surgeries to address significant AF defects.

3 December 2022 in Polymers
Verified
Journal Article
Open access
PDF file
JSJian Su
Jian Su
JWJianjun Wang
Jianjun Wang
SYS.T. Yan
S.T. Yan
MZMin Zhang
Min Zhang
NZNing-Ze Zhang
Ning-Ze Zhang
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng
The wear of the tibial insert is one of the primary factors leading to the failure of total knee arthroplasty. As materials age, their wear performance often degrades. Supplementing highly cross-linked polyethylene (HXLPE) with dodecyl gallate (DG) can improve the oxidation stability of tibial inserts for use in total knee arthroplasty (TKA). This study aimed to evaluate the wear resistance of HXLPE supplemented with DG (HXLPE-DG) tibial inserts before and after accelerated aging. HXLPE-DG tibial inserts were subjected to wear testing of up to 5 million loading cycles according to ISO 14243, and the resulting wear particles were analyzed according to ISO 17853. The wear rate, number, size, and shape of the wear particles were analyzed. The average wear rate of the unaged samples was 4.39 ± 0.75 mg/million cycles and was 3.22 ± 1.49 mg/million cycles for the aged samples. The unaged tibial inserts generated about 2.80 × 107 particles/mL following the wear test, but this was considerably lower for the aged samples at about 1.35 × 107 particles/mL. The average equivalent circle diameter (ECD) of the wear particles from the unaged samples was 0.13 μm (max: 0.80 μm; min: 0.04 μm), and it was 0.14 μm (max: 0.66 μm; min: 0.06 μm) from the aged samples. Moreover, 22.1% of the wear particles from the unaged samples had an aspect ratio (AR) of >4 (slender shape), while this was 15.4% for the aged samples. HXLPE-DG improves the wear performance of the material over time. HXLPE-DG is a novel material that has been demonstrated to have antiaging properties and high wear resistance, making it a promising candidate for use in TKA. Nevertheless, the results are preliminary and will be clarified in further studies.