Purpose: To address the systematic bias in whole‐brain dual flip angle (DFA) T1‐mapping at 7T by optimizing the flip angle pair and carefully selecting radiofrequency (RF) pulse shape and duration.Theory and Methods: Spoiled gradient echoes can be used to estimate whole‐brain maps of T1. This can be accomplished by using only two acquisitions with different flip angles, that is, a DFA‐based approach. Although DFA‐based T1‐mapping is seemingly straightforward to implement, it is sensitive to bias caused by incomplete spoiling and incidental magnetization transfer effects. Further bias is introduced by the increased B0 and inhomogeneities at 7T. Experiments were performed to determine the optimal flip angle pair and appropriate RF pulse shape and duration. Obtained T1 estimates were validated using inversion recovery prepared echo planar imaging and compared to literature values. A multi‐echo readout was used to increase signal‐to‐noise ratio, enabling quantification of and susceptibility, χ.Results: Incomplete spoiling was observed above a local flip angle of approximately 20°. An asymmetric gauss‐filtered sinc pulse with a constant duration of 700 μs showed a sufficiently flat frequency response profile to avoid incomplete excitation in areas with high B0 offsets. A pulse duration of 700 μs minimized effects from incidental magnetization transfer.Conclusion: When performing DFA‐based T1‐mapping one should (a) limit the higher flip angle to avoid incomplete spoiling, (b) use a RF pulse shape insensitive to B0 inhomogeneities and (c) apply a constant RF pulse duration, balanced to minimize incidental magnetization transfer.
Purpose: To map T1 and the local flip angle () in human brain using a single MP3RAGE sequence with 3 rapid acquisitions of gradient echoes (RAGEs).Theory and methods: A third RAGE with a relatively high flip angle was appended to an MP2RAGE sequence. Through curve fitting and a rational approximation for small flip angles and short TR, closed form solutions for T1 and were derived. The influence of different k‐space encoding schemes on precision and whether edge enhancement artifacts could be reduced with a saturation pulse applied prior to the third RAGE were explored. Validation of T1 estimates was performed using single‐slice inversion recovery (IR) and a subsequent region‐of‐interest–based comparison, whereas validation of was performed using a whole brain pixelwise comparison to a DREAM flip angle mapping protocol. Lastly, MP3RAGE was compared to T1‐mapping by MP2RAGE with separate correction.Results: Whole brain maps of T1 and at 1 mm isotropic resolution were obtained with MP3RAGE in 06:37 min. A linear–reverse centric–reverse centric phase‐encoding order of the 3 RAGEs improved precision, and artifacts were successfully reduced with the saturation pulse. Estimations of T1 and deviated +2.5 ± 3.1% and −1.7 ± 8.6% from their respective references.Conclusion: T1 and can be mapped simultaneously using MP3RAGE. The approach can be thought of as combining MP2RAGE with a dual flip angle T1‐mapping protocol. Both maps can be solved for analytically and will be inherently co‐registered at the high resolution associated with MPRAGE.
Purpose: To optimize a whole‐brain magnetization transfer saturation (MTsat) protocol at 7T, focusing on maximizing obtainable MTsat under the constraints of specific absorption rate (SAR) and transmit field inhomogeneity, while avoiding bias and keeping scan time short.Theory and Methods: MTsat is a semi‐quantitative metric, obtained by spoiled gradient‐echo MRI in the imaging steady‐state. Optimization was based on an established 7T dual flip angle protocol, and focused on MT pulse, readout flip angle, repetition time (TR), offset frequency (Δ), and correction of residual effects from transmit field inhomogeneities by separate flip angle mapping.Results: A 100% SAR level was reached at a 180° MT pulse flip angle, using a compact sinc main lobe (4 ms duration) and minimum TR = 26.5 ms. The use of Δ = +2.0 kHz caused no discernible direct saturation, while Δ = −2.0 kHz resulted in 45% higher MTsat in white matter (WM) compared to Δ = +2.0 kHz. A 4° readout flip angle eliminated bias while yielding a good signal‐to‐noise ratio. Increased TR yielded only a little increase in MTsat, and TR = 26.5 ms (scan time 04:58 min) was thus selected. Post hoc transmit field correction clearly improved homogeneity, especially in WM.Conclusions: The range of MTsat is limited at 7T, and this can partly be overcome by the exploitation of the asymmetry of the macromolecular lineshape through the sign of Δ. To reduce scan time, a compact MT pulse with a sufficiently narrow frequency response should be used. TR and readout flip angle should be kept short/small. Transmit field correction through separate flip angle mapping is required.
Magnetic Resonance Imaging (MRI) datasets from epidemiological studies often show a lower prevalence of motion artifacts than what is encountered in clinical practice. These artifacts can be unevenly distributed between subject groups and studies which introduces a bias that needs addressing when augmenting data for machine learning purposes. Since unreconstructed multi-channel k-space data is typically not available for population-based MRI datasets, motion simulations must be performed using signal magnitude data. There is thus a need to systematically evaluate how realistic such magnitude-based simulations are. We performed magnitude-based motion simulations on a dataset (MR-ART) from 148 subjects in which real motion-corrupted reference data was also available. The similarity of real and simulated motion was assessed by using image quality metrics (IQMs) including Coefficient of Joint Variation (CJV), Signal-to-Noise-Ratio (SNR), and Contrast-to-Noise-Ratio (CNR). An additional comparison was made by investigating the decrease in the Dice-Sørensen Coefficient (DSC) of automated segmentations with increasing motion severity. Segmentation of the cerebral cortex was performed with 6 freely available tools: FreeSurfer, BrainSuite, ANTs, SAMSEG, FastSurfer, and SynthSeg+. To better mimic the real subject motion, the original motion simulation within an existing data augmentation framework (TorchIO), was modified. This allowed a non-random motion paradigm and phase encoding direction. The mean difference in CJV/SNR/CNR between the real motion-corrupted images and our modified simulations (0.004±0.054/-0.7±1.8/-0.09±0.55) was lower than that of the original simulations (0.015±0.061/0.2±2.0/-0.29±0.62). Further, the mean difference in the DSC between the real motion-corrupted images was lower for our modified simulations (0.03±0.06) compared to the original simulations (-0.15±0.09). SynthSeg+ showed the highest robustness towards all forms of motion, real and simulated. In conclusion, reasonably realistic synthetic motion artifacts can be induced on a large-scale when only magnitude MR images are available to obtain unbiased data sets for the training of machine learning based models.
At field strengths of 7 T and above, T1-weighted imaging of human brain suffers increasingly from radiofrequency (RF) B1 inhomogeneities. The well-known MP2RAGE (magnetization prepared two rapid acquisition gradient echoes) sequence provides a solution but may not be readily available for all MR systems. Here, we describe the implementation and evaluation of a sequential protocol to obtain normalized magnetization prepared rapid gradient echo (MPRAGE) images at 0.7, 0.8, or 0.9-mm isotropic spatial resolution. Optimization focused on the reference gradient-recalled echo (GRE) that was used for normalization of the MPRAGE. A good compromise between white-gray matter contrast and the signal-to-noise ratio (SNR) was reached at a flip angle of 3° and total scan time was reduced by increasing the reference voxel size by a factor of 8 relative to the MPRAGE resolution. The average intra-subject coefficient-of-variation (CV) in segmented white matter (WM) was 7.9 ± 3.3% after normalization, compared to 20 ± 8.4% before. The corresponding inter-subject average CV in WM was 7.6 ± 7.6% and 13 ± 7.8%. Maps of T1 derived from forward signal modelling showed no obvious bias after correction by a separately acquired flip angle map. To conclude, a non-interleaved acquisition for normalization of MPRAGE offers a simple alternative to MP2RAGE to obtain semi-quantitative purely T1-weighted images. These images can be converted to T1 maps, analogously to the established MP2RAGE approach. Scan time can be reduced by increasing the reference voxel size which has only a miniscule effect on image quality.