Mads Andersen

Mads Andersen

Auto-generated profile, based on publicly available information

Mads Andersen

Philips Healthcare Copenhagen Denmark

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MAMads Andersen
Mads Andersen
IBIsabella M. Björkman-Burtscher
Isabella M. Björkman-Burtscher
AMAnouk Marsman
Anouk Marsman
EPEsben Thade Petersen
Esben Thade Petersen
VBVincent Oltman Boer
Vincent Oltman Boer
Subject movements lead to severe artifacts in magnetic resonance (MR) brain imaging. In this study we evaluate the diagnostic image quality in T1-weighted, T2-weighted, and time-of-flight angiographic MR sequences when using a flexible, navigator-based prospective motion correction system (iMOCO). Five healthy volunteers were scanned during different movement scenarios with and without (+/-) iMOCO activated. An experienced neuroradiologist graded images for image quality criteria (grey-white-matter discrimination, basal ganglia, and small structure and vessel delineation), and general image quality on a four-grade scale. In scans with deliberate motion, there was a significant improvement in the image quality with iMOCO compared to the scans without iMOCO in both general image impression (T1 p<0.01, T2 p<0.01, TOF p = 0.03) and in anatomical grading (T1 p<0.01, T2 p<0.01, TOF p = 0.01). Subjective image quality was considered non-diagnostic in 91% of the scans with motion -iMOCO, but only in 4% of the scans with motion +iMOCO. iMOCO performed best in the T1-weighted sequence and least well in the angiography sequence. iMOCO was not shown to have any negative effect on diagnostic image quality, as no significant difference in diagnostic quality was seen between scans -iMOCO and +iMOCO with no deliberate movement. The evaluation showed that iMOCO enables substantial improvements in image quality in scans affected by subject movement, recovering important diagnostic information in an otherwise unusable scan.

1 December 2018 in Tomography
Verified
Journal Article
Open access
LKLinda Knutsson
Linda Knutsson
ASAnina Seidemo
Anina Seidemo
ASAnna Rydhög Scherman
Anna Rydhög Scherman
KBKarin Markenroth Bloch
Karin Markenroth Bloch
RKRita R. Kalyani
Rita R. Kalyani
XXXiang Xu
Xiang Xu
Dynamic glucose-enhanced (DGE) imaging uses chemical exchange saturation transfer magnetic resonance imaging to retrieve information about the microcirculation using infusion of a natural sugar (D-glucose). However, this new approach is not yet well understood with respect to the dynamic tissue response. DGE time curves for arteries, normal brain tissue, and cerebrospinal fluid (CSF) were analyzed in healthy volunteers and compared with the time dependence of sampled venous plasma blood glucose levels. The arterial response curves (arterial input function [AIF]) compared reasonably well in shape with the time curves of the sampled glucose levels but could also differ substantially. The brain tissue response curves showed mainly negative responses with a peak intensity that was of the order of 10 times smaller than the AIF peak and a shape that was susceptible to both noise and partial volume effects with CSF, attributed to the low contrast-to-noise ratio. The CSF response curves showed a rather large and steady increase of the glucose uptake during the scan, due to the rapid uptake of D-glucose in CSF. Importantly, and contrary to gadolinium studies, the curves differed substantially among volunteers, which was interpreted to be caused by variations in insulin response. In conclusion, while AIFs and tissue response curves can be measured in DGE experiments, partial volume effects, low concentration of D-glucose in tissue, and osmolality effects between tissue and blood may prohibit quantification of normal tissue perfusion parameters. However, separation of tumor responses from normal tissue responses would most likely be feasible.

10 April 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
JTJohannes Töger
Johannes Töger
MAMads Andersen
Mads Andersen
OHOlle Haglund
Olle Haglund
TKTekla Maria Kylkilahti
Tekla Maria Kylkilahti
ILIben Lundgaard
Iben Lundgaard
KBKarin Markenroth Bloch
Karin Markenroth Bloch
Purpose: Respiration‐related CSF flow through the cerebral aqueduct may be useful for elucidating physiology and pathophysiology of the glymphatic system, which has been proposed as a mechanism of brain waste clearance. Therefore, we aimed to (1) develop a real‐time (CSF) flow imaging method with high spatial and sufficient temporal resolution to capture respiratory effects, (2) validate the method in a phantom setup and numerical simulations, and (3) apply the method in vivo and quantify its repeatability and correlation with different respiratory conditions.Methods: A golden‐angle radial flow sequence (reconstructed temporal resolution 168 ms, spatial resolution 0.6 mm) was implemented on a 7T MRI scanner and reconstructed using compressed sensing. A phantom setup mimicked simultaneous cardiac and respiratory flow oscillations. The effect of temporal resolution and vessel diameter was investigated numerically. Healthy volunteers (n = 10) were scanned at four different respiratory conditions, including repeat scans.Results: Phantom data show that the developed sequence accurately quantifies respiratory oscillations (ratio real‐time/reference QR = 0.96 ± 0.02), but underestimates the rapid cardiac oscillations (ratio QC = 0.46 ± 0.14). Simulations suggest that QC can be improved by increasing temporal resolution. In vivo repeatability was moderate to very strong for cranial and caudal flow (intraclass correlation coefficient range: 0.55–0.99) and weak to strong for net flow (intraclass correlation coefficient range: 0.48–0.90). Net flow was influenced by respiratory condition (p < 0.01).Conclusions: The presented real‐time flow MRI method can quantify respiratory‐related variations of CSF flow in the cerebral aqueduct, but it underestimates rapid cardiac oscillations. In vivo, the method showed good repeatability and a relationship between flow and respiration.

14 February 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
HOHampus Olsson
Hampus Olsson
MAMads Andersen
Mads Andersen
JLJimmy Lätt
Jimmy Lätt
RWRonnie Wirestam
Ronnie Wirestam
GHGunther Helms
Gunther Helms
Purpose: To address the systematic bias in whole‐brain dual flip angle (DFA) T1‐mapping at 7T by optimizing the flip angle pair and carefully selecting radiofrequency (RF) pulse shape and duration.Theory and Methods: Spoiled gradient echoes can be used to estimate whole‐brain maps of T1. This can be accomplished by using only two acquisitions with different flip angles, that is, a DFA‐based approach. Although DFA‐based T1‐mapping is seemingly straightforward to implement, it is sensitive to bias caused by incomplete spoiling and incidental magnetization transfer effects. Further bias is introduced by the increased B0 and inhomogeneities at 7T. Experiments were performed to determine the optimal flip angle pair and appropriate RF pulse shape and duration. Obtained T1 estimates were validated using inversion recovery prepared echo planar imaging and compared to literature values. A multi‐echo readout was used to increase signal‐to‐noise ratio, enabling quantification of and susceptibility, χ.Results: Incomplete spoiling was observed above a local flip angle of approximately 20°. An asymmetric gauss‐filtered sinc pulse with a constant duration of 700 μs showed a sufficiently flat frequency response profile to avoid incomplete excitation in areas with high B0 offsets. A pulse duration of 700 μs minimized effects from incidental magnetization transfer.Conclusion: When performing DFA‐based T1‐mapping one should (a) limit the higher flip angle to avoid incomplete spoiling, (b) use a RF pulse shape insensitive to B0 inhomogeneities and (c) apply a constant RF pulse duration, balanced to minimize incidental magnetization transfer.

17 January 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
HOHampus Olsson
Hampus Olsson
MAMads Andersen
Mads Andersen
MKMustafa Kadhim
Mustafa Kadhim
GHGunther Helms
Gunther Helms
Purpose: To map T1 and the local flip angle () in human brain using a single MP3RAGE sequence with 3 rapid acquisitions of gradient echoes (RAGEs).Theory and methods: A third RAGE with a relatively high flip angle was appended to an MP2RAGE sequence. Through curve fitting and a rational approximation for small flip angles and short TR, closed form solutions for T1 and were derived. The influence of different k‐space encoding schemes on precision and whether edge enhancement artifacts could be reduced with a saturation pulse applied prior to the third RAGE were explored. Validation of T1 estimates was performed using single‐slice inversion recovery (IR) and a subsequent region‐of‐interest–based comparison, whereas validation of was performed using a whole brain pixelwise comparison to a DREAM flip angle mapping protocol. Lastly, MP3RAGE was compared to T1‐mapping by MP2RAGE with separate correction.Results: Whole brain maps of T1 and at 1 mm isotropic resolution were obtained with MP3RAGE in 06:37 min. A linear–reverse centric–reverse centric phase‐encoding order of the 3 RAGEs improved precision, and artifacts were successfully reduced with the saturation pulse. Estimations of T1 and deviated +2.5 ± 3.1% and −1.7 ± 8.6% from their respective references.Conclusion: T1 and can be mapped simultaneously using MP3RAGE. The approach can be thought of as combining MP2RAGE with a dual flip angle T1‐mapping protocol. Both maps can be solved for analytically and will be inherently co‐registered at the high resolution associated with MPRAGE.

25 April 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
MLMalte Laustsen
Malte Laustsen
MAMads Andersen
Mads Andersen
RXRong Xue
Rong Xue
KMKristoffer Hougaard Madsen
Kristoffer Hougaard Madsen
LHLars G. Hanson
Lars G. Hanson
Purpose: To demonstrate a novel method for tracking of head movements during MRI using electroencephalography (EEG) hardware for recording signals induced by native imaging gradients.Theory and Methods: Gradient switching during simultaneous EEG–fMRI induces distortions in EEG signals, which depend on subject head position and orientation. When EEG electrodes are interconnected with high‐impedance carbon wire loops, the induced voltages are linear combinations of the temporal gradient waveform derivatives. We introduce head tracking based on these signals (CapTrack) involving 3 steps: (1) phantom scanning is used to characterize the target sequence and a fast calibration sequence; (2) a linear relation between changes of induced signals and head pose is established using the calibration sequence; and (3) induced signals recorded during target sequence scanning are used for tracking and retrospective correction of head movement without prolonging the scan time of the target sequence. Performance of CapTrack is compared directly to interleaved navigators.Results: Head‐pose tracking at 27.5 Hz during echo planar imaging (EPI) was demonstrated with close resemblance to rigid body alignment (mean absolute difference: [0.14 0.38 0.15]‐mm translation, [0.30 0.27 0.22]‐degree rotation). Retrospective correction of 3D gradient‐echo imaging shows an increase of average edge strength of 12%/−0.39% for instructed/uninstructed motion with CapTrack pose estimates, with a tracking interval of 1561 ms and high similarity to interleaved navigator estimates (mean absolute difference: [0.13 0.33 0.12] mm, [0.28 0.15 0.22] degrees).Conclusion: Motion can be estimated from recordings of gradient switching with little or no sequence modification, optionally in real time at low computational burden and synchronized to image acquisition, using EEG equipment already found at many research institutions.