Ronnie Wirestam

Prof. Ronnie Wirestam

Department of Medical Radiation Physics, Lund University, 221 85 Lund, Sweden
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in NeuroImage
Verified
Journal Article
Closed access
ARAnna S. Rydhög
Anna S. Rydhög
FSFilip Szczepankiewicz
Filip Szczepankiewicz
RWRonnie Wirestam
Ronnie Wirestam
AAAndré Ahlgren
André Ahlgren
CWCarl-Fredrik Westin
Carl-Fredrik Westin
OPOfer Pasternak
Ofer Pasternak

19 September 2006 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
RWRonnie Wirestam
Ronnie Wirestam
ABAdnan Bibic
Adnan Bibic
JLJimmy Lätt
Jimmy Lätt
SBSara Brockstedt
Sara Brockstedt
FSFreddy Ståhlberg
Freddy Ståhlberg

7 March 2006 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
LKLinda Knutsson
Linda Knutsson
ELElna-Marie Larsson
Elna-Marie Larsson
OTOliver Thilmann
Oliver Thilmann
FSFreddy Ståhlberg
Freddy Ståhlberg
RWRonnie Wirestam
Ronnie Wirestam
Purpose To calculate regional cerebral blood volume (rCBV), regional cerebral blood flow (rCBF), and regional mean transit time (rMTT) accurately, an arterial input function (AIF) is required. In this study we identified a number of AIFs using factor analysis of dynamic studies (FADS), and performed the cerebral perfusion calculation pixel by pixel using the AIF that was located geometrically closest to a certain voxel. Materials and Methods To verify the robustness of the method, simulated images were generated in which dispersion or delay was added in some arteries and in the corresponding cerebral gray matter (GM), white matter (WM), and ischemic tissue. Thereafter, AIFs were determined using the FADS method and simulations were performed using different signal-to-noise ratios (SNRs). Simulations were also carried out using an AIF from a single pixel that was manually selected. In vivo results were obtained from normal volunteers and patients. Results The FADS method reduced the underestimation of rCBF due to dispersion or delay that often occurs when only one AIF represents the entire brain. Conclusion This study indicates that the use of FADS and the nearest-AIF method is preferable to manual selection of one single AIF. J. Magn. Reson. Imaging 2006.

14 February 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
HOHampus Olsson
Hampus Olsson
MAMads Andersen
Mads Andersen
JLJimmy Lätt
Jimmy Lätt
RWRonnie Wirestam
Ronnie Wirestam
GHGunther Helms
Gunther Helms
Purpose: To address the systematic bias in whole‐brain dual flip angle (DFA) T1‐mapping at 7T by optimizing the flip angle pair and carefully selecting radiofrequency (RF) pulse shape and duration.Theory and Methods: Spoiled gradient echoes can be used to estimate whole‐brain maps of T1. This can be accomplished by using only two acquisitions with different flip angles, that is, a DFA‐based approach. Although DFA‐based T1‐mapping is seemingly straightforward to implement, it is sensitive to bias caused by incomplete spoiling and incidental magnetization transfer effects. Further bias is introduced by the increased B0 and inhomogeneities at 7T. Experiments were performed to determine the optimal flip angle pair and appropriate RF pulse shape and duration. Obtained T1 estimates were validated using inversion recovery prepared echo planar imaging and compared to literature values. A multi‐echo readout was used to increase signal‐to‐noise ratio, enabling quantification of and susceptibility, χ.Results: Incomplete spoiling was observed above a local flip angle of approximately 20°. An asymmetric gauss‐filtered sinc pulse with a constant duration of 700 μs showed a sufficiently flat frequency response profile to avoid incomplete excitation in areas with high B0 offsets. A pulse duration of 700 μs minimized effects from incidental magnetization transfer.Conclusion: When performing DFA‐based T1‐mapping one should (a) limit the higher flip angle to avoid incomplete spoiling, (b) use a RF pulse shape insensitive to B0 inhomogeneities and (c) apply a constant RF pulse duration, balanced to minimize incidental magnetization transfer.

1 January 2019 in European Journal of Radiology Open
Verified
Journal Article
Open access
ARAnna Rydhög
Anna Rydhög
OPOfer Pasternak
Ofer Pasternak
FSFreddy Ståhlberg
Freddy Ståhlberg
AAAndré Ahlgren
André Ahlgren
LKLinda Knutsson
Linda Knutsson
RWRonnie Wirestam
Ronnie Wirestam
Compartmental diffusion MRI models that account for intravoxel incoherent motion (IVIM) of blood perfusion allow for estimation of the fractional volume of the microvascular compartment. Conventional IVIM models are known to be biased by not accounting for partial volume effects caused by free water and cerebrospinal fluid (CSF), or for tissue-dependent relaxation effects. In this work, a three-compartment model (tissue, free water and blood) that includes relaxation terms is introduced. To estimate the model parameters, in vivo human data were collected with multiple echo times (TE), inversion times (TI) and b-values, which allowed a direct relaxation estimate alongside estimation of perfusion, diffusion and fractional volume parameters. Compared to conventional two-compartment models (with and without relaxation compensation), the three-compartment model showed less effects of CSF contamination. The proposed model yielded significantly different volume fractions of blood and tissue compared to the non-relaxation-compensated model, as well as to the conventional two-compartment model, suggesting that previously reported parameter ranges, using models that do not account for relaxation, should be reconsidered.

1 July 2010 in European Journal of Radiology
Verified
Journal Article
Closed access
RWRonnie Wirestam
Ronnie Wirestam
OTOliver Thilmann
Oliver Thilmann
LKLinda Knutsson
Linda Knutsson
IBIsabella M. Björkman-Burtscher
Isabella M. Björkman-Burtscher
ELElna-Marie Larsson
Elna-Marie Larsson
FSFreddy Ståhlberg
Freddy Ståhlberg