Two-phase closed thermosyphons (TPCTs) are widely utilized as heat exchanger elements in waste heat recovery systems and as passive heating/cooling devices. They are popular because of their high thermal conductivity, simple construction and reliability. Previous researches indicate that refrigerants are performing better than typical TPCT working fluids like deionized water or alcohols in the low temperature range. In the present study three HFC (Hydrofluorocarbons) refrigerants were tested: R134a, R404A and R407C. The total length of the investigated TPCT is 550 mm with equal length (245 mm) condenser and evaporator sections. Its outer diameter is 22 mm with 1 mm wall thickness. The evaporator section was heated by hot water with varying inlet temperature by 5 K step in the range of 288 K – 323 K. The condenser was cooled by cold water with inlet temperature kept at a constant value of 283 K. It was found that using R134a and R404A as working fluids heat transfer rates are the highest. For both refrigerants 10% is optimal filling ratio. They can be utilized interchangeably because the differences between their throughputs are within uncertainty bands. R407C performance was 50% lower. Other disadvantages of using this refrigerant are relatively high working pressures and higher optimal filling ratio (30%).
The present study is devoted to the modeling, design, and experimental study of a heat pipe heat exchanger utilized as a recuperator in small air conditioning systems (airflow ≈ 300–500 m3/h), comprised of individually finned heat pipes. A thermal heat pipe heat exchanger model was developed, based on available correlations. Based on the previous experimental works of authors, refrigerant R404A was recognized as the best working fluid with a 20% heat pipe filling ratio. An engineering analysis of parametric calculations performed with the aid of the computational model concluded 20 rows of finned heat pipes in the staggered arrangement as a guarantee of stable heat exchanger effectiveness ≈ 60%. The optimization of the overall cost function by the “brute-force” method has backed up the choice of the best heat exchanger parameters. The 0.05 m traversal (finned pipes in contact with each other) and 0.062 m longitudinal distance were optimized to maximize effectiveness (up to 66%) and minimize pressure drop (less than 150 Pa). The designed heat exchanger was constructed and tested on the experimental rig. The experimental data yielded a good level of agreement with the model—relative difference within 10%.
Plate fin-tube heat exchangers are widely used in air conditioning and refrigeration systems and other industry fields. Various errors made in the manufacturing process can result in the formation of an air gap between the tube and fin. Several numerical simulations were carried out for a symmetric section of plate fin-tube heat exchanger to study the influence of air gap on heat transfer under periodic flow conditions. Different locations and sizes of an air gap spanning 1/2 circumference of the tube were considered for the range of airflow velocities. Velocity and temperature fields for cases with air gap were compared with ideal thermal contact cases. Blocking of heat flow by the gap leads to the reduction of heat transfer rate. Fin discontinuity in the front of the tube causes the smallest reduction of the heat transfer rate in comparison to the ideal tube-fin contact, especially for thin slits. The rear gap position is the worst in the smallest gap range. Therefore, reversing the flow direction can lead to up to a 15% heat transfer increase, if mainly the rear gaps are present. The introduction of a thin slit in the front of the tube leads to convective heat transfer enhancement, which should be further investigated.
This paper presents the results of an optimization analysis of two types of thermal fluid channels. The selected geometries were evaluated according to the criterion of the Entropy Generation Minimization method as suggested by Adrian Bejan, with reference to a smooth pipe of the same diameter. The aim of this research was to assess the effectiveness of two channels that intensify heat transfer in different ways: with an insert (disrupting the flow in the pipe core) and with internal fins (disrupting the flow at the pipe wall), and to compare the results using the same criterion: the EGM method. The tested insert consisted of spaced streamline-shaped flow turbulizing the elements fixed in the axis of the pipe and spaced at equal distances from each other. The second channel was formed by making a right-angled triangle (rib profile) on the deformation of the pipe wall perimeter. Using computer modeling, the effect of the two geometric parameters of the above-mentioned channels on the flux of entropy generated was studied. These are (a) the diameter of the disturbing element (“droplet”) and the distance between these elements for a channel with a turbulent insert, and (b) the height of the rib and the longitudinal distance between them for a finned channel. The novelty resulting from the research is the discovery that the turbulization of the flow in the pipe wall boundary layer generates significantly less irreversible entropy than the disturbance of the flow in the pipe axis by the insert.
The article presents the results of a study on heat transfer within the engine block of the Eco Arrow 3 prototype vehicle, developed for participation in Shell Eco-marathon competitions. The main objective of these events is to minimize fuel consumption during track races, which leads to a specific driving strategy characterized by frequent engine shut-downs and restarts. Such a driving style introduces challenges not typically encountered in conventional vehicles, including the need to maintain the engine within an optimal temperature range. In this work, several geometric variants of cylinder finning were investigated with respect to their influence on cooling, heating, and heat accumulation. Four configurations of finning were analysed: the original fins with a height of h = 15 mm, a cylinder with fins completely removed (h = 0 mm), and two intermediate variants with fin heights of 5 mm and 10 mm. The original and finless cylinders were studied both experimentally and numerically, while the intermediate variants were analysed solely using numerical methods. A comparison between experimental and numerical results showed satisfactory agreement in terms of maximum temperatures, with differences of approximately 10–15 °C. Considering the specific operating conditions of such an engine, characterized by irregular on–off cycles, the numerical analysis indicated that fins with a height of h = 10 mm provide the most favourable balance, ensuring that the engine remains within the optimal temperature range required to achieve minimal fuel consumption.