Sunghee Jung

Sunghee Jung


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2020 in IEEE Access
Verified
Journal Article
Open access
SJSunghee Jung
Sunghee Jung
SLSoochahn Lee
Soochahn Lee
BJByunghwan Jeon
Byunghwan Jeon
YJYeonggul Jang
Yeonggul Jang
HCHyuk-Jae Chang
Hyuk-Jae Chang
Motion artifacts may occur in coronary computed tomography angiography (CCTA) due to the heartbeat and impede the clinicianb’s diagnosis of coronary arterial diseases. Thus, motion artifact correction of the coronary artery is required to quantify the risk of disease more accurately. We present a novel method based on deep learning for motion artifact correction in CCTA. Because the image of the coronary artery without motion (the ground-truth data required in supervised deep learning) is medically unattainable, we apply a style transfer method to 2D image patches cropped from full-phase 4D computed tomography (CT) to synthesize these images. We then train a convolutional neural network (CNN) for motion artifact correction using this synthetic ground-truth (SynGT). During testing, the output motion-corrected 2D image patches of the trained network are reinserted into the 3D CT volume with volumetric interpolation. The proposed method is evaluated using both phantom and clinical data. A phantom study demonstrates comparable results to other methods in quantitative performance and outperforms those methods in computation time. For clinical data, a quantitative analysis based on metric measurements is presented that confirms the correction of motion artifacts. Moreover, an observer study finds that by applying the proposed method, motion artifacts are markedly reduced, and boundaries of the coronary artery are much sharper, with a strong inter-observer agreement (κ=0.78). Finally, evaluations using commercial software on the original and resulting CT volumes of the proposed method reveal a considerable increase in tracked coronary artery length.

1 February 2022 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
KHKyunghoon Han
Kyunghoon Han
JJJaeik Jeon
Jaeik Jeon
YJYeonggul Jang
Yeonggul Jang
SJSunghee Jung
Sunghee Jung
SKSekeun Kim
Sekeun Kim
HCHyuk-Jae Chang
Hyuk-Jae Chang

3 March 2025 in Pattern Recognition
Verified
Journal Article
Closed access
SCSeungpil Choi
Seungpil Choi
SJSeoyeon Jang
Seoyeon Jang
SJSunghee Jung
Sunghee Jung
HCHeon Jae Cho
Heon Jae Cho
BJByunghwan Jeon
Byunghwan Jeon

3 August 2023 in IEEE Access
Verified
Journal Article
Open access
KHKyunghoon Han
Kyunghoon Han
HKHeejoon Koo
Heejoon Koo
SJSunghee Jung
Sunghee Jung
HPHyung-Bok Park
Hyung-Bok Park
YHYoungtaek Hong
Youngtaek Hong
HCHyuk-Jae Chang
Hyuk-Jae Chang
Coronary artery procedures are primarily performed based on X-ray angiography images. However, coronary arteries in X-ray images are often partially broken, complicating diagnoses and procedures owing to lack of visibility. In this paper, we propose a fully automatic method to restore locally broken parts of coronary arteries in X-ray images without using any external information, such as computed tomography images. To this end, we design a new multi-scale generative adversarial network and a vesselness-loss function. The proposed method is optimized for focus on elongated structures and can be utilized in various clinical applications. The proposed method is evaluated and compared with four other existing methods using the performance metrics, PSNR, MSE, and SSIM, and the result shows 34.3, 0.18, and 0.91 averages, respectively for each metric. Based on the performance result, the blocked regions are plausibly reconstructed into such original shapes of blood vessels, which can aid in image-based guiding catheter manipulation during coronary artery procedures. Eventually, the proposed method can be utilized in various clinical applications, e.g.,image-based planning and guidance of coronary procedures and prior simulation of results.

1 January 2020 in Yonsei Medical Journal
Verified
Journal Article
Open access
PDF file
HPHyung-Bok Park
Hyung-Bok Park
YJYeonggul Jang
Yeonggul Jang
RAReza Arsanjani
Reza Arsanjani
MNMinh Tuan Nguyen
Minh Tuan Nguyen
BJByunghwan Jeon
Byunghwan Jeon
HCHyuk-Jae Chang
Hyuk-Jae Chang
Park HB, et al. Yonsei Med J. 2020 Feb;61(2):137-144. https://doi.org/10.3349/ymj.2020.61.2.137

23 February 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ASAmal Muhammad Saleem
Amal Muhammad Saleem
SJSunghee Jung
Sunghee Jung
HCHyuk-Jae Chang
Hyuk-Jae Chang
SLSoochahn Lee
Soochahn Lee
In coronary computed tomography angiography (CCTA), motion artifacts due to heartbeats can obscure coronary artery diagnoses. In this study, we introduce a cycle-consistent adversarial-network-based method for motion artifact correction in CCTA. Our methodology involves extracting image patches and using style transfer for synthetic ground truth creation, followed by CycleGAN network training for motion compensation. We employ Dynamic Time Warping (DTW) to align extracted image patches along the artery centerline with their corresponding motion-free phase patches, ensuring matched pixel correspondences and similar anatomical features for accuracy in subsequent processing steps. Our quantitative analysis, using metrics like the Dice Similarity Coefficient (DSC) and Hausdorff Distance (HD), demonstrates CycleGAN’s superior performance in reducing motion artifacts, with improvements in image quality and clarity. An observer study using a 5-point Likert scale further validates the reduction of motion artifacts and improved visibility of coronary arteries. Additionally, we present a quantitative analysis on clinical data, affirming the correction of motion artifacts through metric-based evaluations.