Andrew Morris

Dr. Andrew Morris

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Steven OssontSteven Ossont
Steven Ossont
PBPhilip Basford
Philip Basford
FBFlorentin Bulot
Florentin Bulot
MAMihaela Apetroaie-Cristea
Mihaela Apetroaie-Cristea
NENatasha H. C. Easton
Natasha H. C. Easton
SCSimon J Cox
Simon J Cox
Air Quality (AQ) is a very topical issue for many cities and has a direct impact on citizen health. The AQ of a large UK city is being investigated using low-cost Particulate Matter (PM) sensors, and the results obtained by these sensors have been compared with government operated AQ stations. In the first pilot deployment, six AQ Internet of Things (IoT) devices have been designed and built, each with four different low-cost PM sensors, and they have been deployed at two locations within the city. These devices are equipped with LoRaWAN wireless network transceivers to test city scale Low-Power Wide Area Network (LPWAN) coverage. The study concludes that (i) the physical device developed can operate at a city scale; (ii) some low-cost PM sensors are viable for monitoring AQ and for detecting PM trends; (iii) LoRaWAN is suitable for city scale sensor coverage where connectivity is an issue. Based on the findings from this first pilot project, a larger LoRaWAN enabled AQ sensor network is being deployed across the city of Southampton in the UK.

15 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
FBFlorentin Bulot
Florentin Bulot
Hugo Savill RussellHugo Savill Russell
Hugo Savill Russell
MRMohsen Rezaei
Mohsen Rezaei
Matthew Stanley JohnsonMatthew Stanley Johnson
Matthew Stanley Johnson
Steven OssontSteven Ossont
Steven Ossont
SCSimon J Cox
Simon J Cox
Airborne particulate matter (PM) exposure has been identified as a key environmental risk factor, associated especially with diseases of the respiratory and cardiovascular system and with almost 9 million premature deaths per year. Low-cost optical sensors for PM measurement are desirable for monitoring exposure closer to the personal level and particularly suited for developing spatiotemporally dense city sensor networks. However, questions remain over the accuracy and reliability of the data they produce, particularly regarding the influence of environmental parameters such as humidity and temperature, and with varying PM sources and concentration profiles. In this study, eight units each of five different models of commercially available low-cost optical PM sensors (40 individual sensors in total) were tested under controlled laboratory conditions, against higher-grade instruments for: lower limit of detection, response time, responses to sharp pollution spikes lasting <1 min , and the impact of differing humidity and PM source. All sensors detected the spikes generated with a varied range of performances depending on the model and presenting different sensitivity mainly to sources of pollution and to size distributions with a lesser impact of humidity. The sensitivity to particle size distribution indicates that the sensors may provide additional information to PM mass concentrations. It is concluded that improved performance in field monitoring campaigns, including tracking sources of pollution, could be achieved by using a combination of some of the different models to take advantage of the additional information made available by their differential response.

29 April 2023 in Heliyon
Verified
Journal Article
Open access
FBFlorentin Bulot
Florentin Bulot
Steven OssontSteven Ossont
Steven Ossont
AMAndrew Morris
Andrew Morris
PBPhilip Basford
Philip Basford
NENatasha H.C. Easton
Natasha H.C. Easton
MLMatthew Loxham
Matthew Loxham
Particulate Matter (PM) low-cost sensors (LCS) present a cost-effective opportunity to improve the spatiotemporal resolution of airborne PM data. Previous studies focused on PM-LCS-reported hourly data and identified, without fully addressing, their limitations. However, PM-LCS provide measurements at finer temporal resolutions. Furthermore, government bodies have developed certifications to accompany new uses of these sensors, but these certifications have shortcomings. To address these knowledge gaps, PM-LCS of two models, 8 Sensirion SPS30 and 8 Plantower PMS5003, were collocated for one year with a Fidas 200S, MCERTS-certified PM monitor and were characterised at 2 min resolution, enabling replication of certification processes, and highlighting their limitations and improvements. Robust linear models using sensor-reported particle number concentrations and relative humidity, coupled with 2-week biannual calibration campaigns, achieved reference-grade performance, at median PM2.5 background concentration of 5.5 μg/m3, demonstrating that, with careful calibration, PM-LCS may cost-effectively supplement reference equipment in multi-nodes networks with fine spatiotemporality.

4 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
FBFlorentin Bulot
Florentin Bulot
Hugo Savill RussellHugo Savill Russell
Hugo Savill Russell
MRMohsen Rezaei
Mohsen Rezaei
Matthew Stanley JohnsonMatthew Stanley Johnson
Matthew Stanley Johnson
Steven OssontSteven Ossont
Steven Ossont
SCSimon J Cox
Simon J Cox
Low-cost Particulate Matter (PM) sensors offer an excellent opportunity to improve our knowledge about this type of pollution. Their size and cost, which support multi-node network deployment, along with their temporal resolution, enable them to report fine spatio-temporal resolution for a given area. These sensors have known issues across performance metrics. Generally, the literature focuses on the PM mass concentration reported by these sensors, but some models of sensors also report Particle Number Concentrations (PNCs) segregated into different PM size ranges. In this study, eight units each of Alphasense OPC-R1, Plantower PMS5003 and Sensirion SPS30 have been exposed, under controlled conditions, to short-lived peaks of PM generated using two different combustion sources of PM, exposing the sensors’ to different particle size distributions to quantify and better understand the low-cost sensors performance across a range of relevant environmental ranges. The PNCs reported by the sensors were analysed to characterise sensor-reported particle size distribution, to determine whether sensor-reported PNCs can follow the transient variations of PM observed by the reference instruments and to determine the relative impact of different variables on the performances of the sensors. This study shows that the Alphasense OPC-R1 reported at least five size ranges independently from each other, that the Sensirion SPS30 reported two size ranges independently from each other and that all the size ranges reported by the Plantower PMS5003 were not independent of each other. It demonstrates that all sensors tested here could track the fine temporal variation of PNCs, that the Alphasense OPC-R1 could closely follow the variations of size distribution between the two sources of PM, and it shows that particle size distribution and composition are more impactful on sensor measurements than relative humidity.

21 April 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
FBFlorentin Bulot
Florentin Bulot
Hugo Savill RussellHugo Savill Russell
Hugo Savill Russell
MRMohsen Rezaei
Mohsen Rezaei
Matthew Stanley JohnsonMatthew Stanley Johnson
Matthew Stanley Johnson
Steven OssontSteven Ossont
Steven Ossont
SCSimon J Cox
Simon J Cox
Low-cost particulate matter (PM) sensors offer an excellent opportunity to improve our knowledge about this type of pollution. Their size and their cost, which support multi-node network deployment, along with their temporal resolution, enable them to report fine spatio-temporal resolution for a given area. These sensors have known issues across performance metrics. Generally, the literature focuses on the PM mass concentration reported by these sensors but some models of sensors also report particle number concentrations (PNC) segregated into different PM size bins. In this study, 8 units of each Alphasense OPC-R1, Plantower PMS5003 and Sensirion SPS30 have been exposed, under controlled conditions, to short-lived peaks of PM generated using two different combustion sources of PM, exposing the sensors to different particle size distributions to quantify and better understand the low cost sensors performance across a range of relevant environmental ranges. The PNC reported by the sensors were analysed. This study showed that there is added value in directly using the PNC reported by the sensors instead of the mass concentrations, which could aid the efforts to calibrate these sensors to a known accuracy. It demonstrated that all sensors tested here could track the fine temporal variation of PNC, that the Alphasense OPC-R1 could closely follow the variations of size distribution between the two sources of PM, and it showed that particle size distribution and composition are more impactful on the sensors measurement than relative humidity.

7 July 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
SLSarah Elizabeth Lu
Sarah Elizabeth Lu
GCGeraldine Clinton-Bailey
Geraldine Clinton-Bailey
FBFrances Burrell
Frances Burrell
RMRichard M. Marsh
Richard M. Marsh
JLJake Ludgate
Jake Ludgate
PWPhillip E. Warwick
Phillip E. Warwick
Microfluidic lab-on-chip (LoC) systems offer significant potential for in situ radiometric analysis while reducing sample handling and secondary waste generation. However, optimisation of photon transport and optical detection efficiency in radiometric microfluidic systems remains underexplored. Here, finite element ray-tracing modelling was combined with experimental validation to develop and optimise a Cherenkov-based microfluidic detection platform for pure β-emitting radionuclides. Two prototype microfluidic detection units (MDUs) incorporating serpentine channel architectures were designed, fabricated, and integrated with a photomultiplier tube detection system. Numerical modelling was used to evaluate photon transport, reflective geometries, and channel configurations prior to fabrication. Experimental validation was conducted using 90Sr/90Y, 36Cl, and 99Tc to assess analytical response and radionuclide compatibility. Both MDUs demonstrated linear response with increasing activity (R² > 0.91), with minimum detectable activities of 21 Bq and 51 Bq obtained for the single- and dual-channel configurations, respectively. Reflective channel configurations enhanced photon collection efficiency, and strong agreement was observed between modelled and experimental results. This work demonstrates the value of modelling-guided optimisation for the development of radiometric microfluidic analytical platforms and highlights the potential of Cherenkov-based LoC systems for in situ radionuclide detection.