Natasha Hazel Celeste Easton

Natasha Hazel Celeste Easton

Auto-generated profile, based on publicly available information

Natasha Hazel Celeste Easton

Southampton Marine and Maritime Institute, University of Southampton, Southampton SO16 7QF, UK

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
FBFlorentin Bulot
Florentin Bulot
Steven OssontSteven Ossont
Steven Ossont
PBPhilip J. Basford
Philip J. Basford
NENatasha H. C. Easton
Natasha H. C. Easton
MAMihaela Apetroaie-Cristea
Mihaela Apetroaie-Cristea
MLMatthew Loxham
Matthew Loxham
Exposure to ambient particulate matter (PM) air pollution is a leading risk factor for morbidity and mortality, associated with up to 8.9 million deaths/year worldwide. Measurement of personal exposure to PM is hindered by poor spatial resolution of monitoring networks. Low-cost PM sensors may improve monitoring resolution in a cost-effective manner but there are doubts regarding data reliability. PM sensor boxes were constructed using four low-cost PM micro-sensor models. Three boxes were deployed at each of two schools in Southampton, UK, for around one year and sensor performance was analysed. Comparison of sensor readings with a nearby background station showed moderate to good correlation (0.61 < r < 0.88, p < 0.0001), but indicated that low-cost sensor performance varies with different PM sources and background concentrations, and to a lesser extent relative humidity and temperature. This may have implications for their potential use in different locations. Data also indicates that these sensors can track short-lived events of pollution, especially in conjunction with wind data. We conclude that, with appropriate consideration of potential confounding factors, low-cost PM sensors may be suitable for PM monitoring where reference-standard equipment is not available or feasible, and that they may be useful in studying spatially localised airborne PM concentrations.

8 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Steven OssontSteven Ossont
Steven Ossont
PBPhilip Basford
Philip Basford
FBFlorentin Bulot
Florentin Bulot
MAMihaela Apetroaie-Cristea
Mihaela Apetroaie-Cristea
NENatasha H. C. Easton
Natasha H. C. Easton
SCSimon J Cox
Simon J Cox
Air Quality (AQ) is a very topical issue for many cities and has a direct impact on citizen health. The AQ of a large UK city is being investigated using low-cost Particulate Matter (PM) sensors, and the results obtained by these sensors have been compared with government operated AQ stations. In the first pilot deployment, six AQ Internet of Things (IoT) devices have been designed and built, each with four different low-cost PM sensors, and they have been deployed at two locations within the city. These devices are equipped with LoRaWAN wireless network transceivers to test city scale Low-Power Wide Area Network (LPWAN) coverage. The study concludes that (i) the physical device developed can operate at a city scale; (ii) some low-cost PM sensors are viable for monitoring AQ and for detecting PM trends; (iii) LoRaWAN is suitable for city scale sensor coverage where connectivity is an issue. Based on the findings from this first pilot project, a larger LoRaWAN enabled AQ sensor network is being deployed across the city of Southampton in the UK.

15 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
FBFlorentin Bulot
Florentin Bulot
Hugo Savill RussellHugo Savill Russell
Hugo Savill Russell
MRMohsen Rezaei
Mohsen Rezaei
Matthew Stanley JohnsonMatthew Stanley Johnson
Matthew Stanley Johnson
Steven OssontSteven Ossont
Steven Ossont
SCSimon J Cox
Simon J Cox
Airborne particulate matter (PM) exposure has been identified as a key environmental risk factor, associated especially with diseases of the respiratory and cardiovascular system and with almost 9 million premature deaths per year. Low-cost optical sensors for PM measurement are desirable for monitoring exposure closer to the personal level and particularly suited for developing spatiotemporally dense city sensor networks. However, questions remain over the accuracy and reliability of the data they produce, particularly regarding the influence of environmental parameters such as humidity and temperature, and with varying PM sources and concentration profiles. In this study, eight units each of five different models of commercially available low-cost optical PM sensors (40 individual sensors in total) were tested under controlled laboratory conditions, against higher-grade instruments for: lower limit of detection, response time, responses to sharp pollution spikes lasting <1 min , and the impact of differing humidity and PM source. All sensors detected the spikes generated with a varied range of performances depending on the model and presenting different sensitivity mainly to sources of pollution and to size distributions with a lesser impact of humidity. The sensitivity to particle size distribution indicates that the sensors may provide additional information to PM mass concentrations. It is concluded that improved performance in field monitoring campaigns, including tracking sources of pollution, could be achieved by using a combination of some of the different models to take advantage of the additional information made available by their differential response.

29 April 2023 in Heliyon
Verified
Journal Article
Open access
FBFlorentin Bulot
Florentin Bulot
Steven OssontSteven Ossont
Steven Ossont
AMAndrew Morris
Andrew Morris
PBPhilip Basford
Philip Basford
NENatasha H.C. Easton
Natasha H.C. Easton
MLMatthew Loxham
Matthew Loxham
Particulate Matter (PM) low-cost sensors (LCS) present a cost-effective opportunity to improve the spatiotemporal resolution of airborne PM data. Previous studies focused on PM-LCS-reported hourly data and identified, without fully addressing, their limitations. However, PM-LCS provide measurements at finer temporal resolutions. Furthermore, government bodies have developed certifications to accompany new uses of these sensors, but these certifications have shortcomings. To address these knowledge gaps, PM-LCS of two models, 8 Sensirion SPS30 and 8 Plantower PMS5003, were collocated for one year with a Fidas 200S, MCERTS-certified PM monitor and were characterised at 2 min resolution, enabling replication of certification processes, and highlighting their limitations and improvements. Robust linear models using sensor-reported particle number concentrations and relative humidity, coupled with 2-week biannual calibration campaigns, achieved reference-grade performance, at median PM2.5 background concentration of 5.5 μg/m3, demonstrating that, with careful calibration, PM-LCS may cost-effectively supplement reference equipment in multi-nodes networks with fine spatiotemporality.

1 July 2025 in European Respiratory Review
Verified
Journal Article
Open access
CSCarmelo Sofia
Carmelo Sofia
JPJames G.H. Parkin
James G.H. Parkin
JBJoseph A. Bell
Joseph A. Bell
LDLareb S.N. Dean
Lareb S.N. Dean
LELiam J. Edgeway
Liam J. Edgeway
MLMatthew Loxham
Matthew Loxham
Exposure to air pollution has been associated with up to 9 million premature deaths per year worldwide, with the respiratory system a key site for its effects. Air pollution exposure is a well-established risk factor for the development and exacerbation of airways diseases and lung cancer, however relatively little is known regarding the risks associated with air pollution interacting with areas of gas exchange – the alveoli and pulmonary interstitium. In recent years, evidence has emerged identifying a role in the development and progression of sub-clinical interstitial lung abnormalities as well as progression and risk of exacerbation of fibrotic interstitial lung diseases. This review outlines the epidemiologic evidence that air pollution perturbs alveolar health. It considers the different components of ambient air pollution, how penetration to the alveoli is determined by particle size and whether the response to alveolar exposure may be modulated by personal susceptibility factors. We discuss potential acute and chronic pathogenic mechanisms of injury upon the pulmonary interstitium and how these may contribute to the development and/or progression of interstitial processes. Finally, we explore current knowledge gaps and the potential for air pollution interventions in vulnerable individuals to support alveolar homeostasis and so prevent disease development and/or progression.

4 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
FBFlorentin Bulot
Florentin Bulot
Hugo Savill RussellHugo Savill Russell
Hugo Savill Russell
MRMohsen Rezaei
Mohsen Rezaei
Matthew Stanley JohnsonMatthew Stanley Johnson
Matthew Stanley Johnson
Steven OssontSteven Ossont
Steven Ossont
SCSimon J Cox
Simon J Cox
Low-cost Particulate Matter (PM) sensors offer an excellent opportunity to improve our knowledge about this type of pollution. Their size and cost, which support multi-node network deployment, along with their temporal resolution, enable them to report fine spatio-temporal resolution for a given area. These sensors have known issues across performance metrics. Generally, the literature focuses on the PM mass concentration reported by these sensors, but some models of sensors also report Particle Number Concentrations (PNCs) segregated into different PM size ranges. In this study, eight units each of Alphasense OPC-R1, Plantower PMS5003 and Sensirion SPS30 have been exposed, under controlled conditions, to short-lived peaks of PM generated using two different combustion sources of PM, exposing the sensors’ to different particle size distributions to quantify and better understand the low-cost sensors performance across a range of relevant environmental ranges. The PNCs reported by the sensors were analysed to characterise sensor-reported particle size distribution, to determine whether sensor-reported PNCs can follow the transient variations of PM observed by the reference instruments and to determine the relative impact of different variables on the performances of the sensors. This study shows that the Alphasense OPC-R1 reported at least five size ranges independently from each other, that the Sensirion SPS30 reported two size ranges independently from each other and that all the size ranges reported by the Plantower PMS5003 were not independent of each other. It demonstrates that all sensors tested here could track the fine temporal variation of PNCs, that the Alphasense OPC-R1 could closely follow the variations of size distribution between the two sources of PM, and it shows that particle size distribution and composition are more impactful on sensor measurements than relative humidity.