The work presents the results of an experimental campaign carried out on concrete elements in order to investigate the potential of using artificial neural networks (ANNs) to estimate the compressive strength based on relevant parameters, such as the water–cement ratio, aggregate–cement ratio, age of testing, and percentage cement/metakaolin ratios (5% and 10%). We prepared 162 cylindrical concrete specimens with dimensions of 10 cm in diameter and 20 cm in height and 27 prismatic specimens with cross sections measuring 25 and 50 cm in length, with 9 different concrete mixture proportions. A longitudinal transducer with a frequency of 54 kHz was used to measure the ultrasonic velocities. An ANN model was developed, different ANN configurations were tested and compared to identify the best ANN model. Using this model, it was possible to assess the contribution of each input variable to the compressive strength of the tested concretes. The results indicate an excellent performance of the ANN model developed to predict compressive strength from the input parameters studied, with an average error less than 5%. Together, the water–cement ratio and the percentage of metakaolin were shown to be the most influential factors for the compressive strength value predicted by the developed ANN model.
This work aims to study the influence of using construction and demolition waste in the replacement of coarse and fine aggregate to produce recycled aggregate concrete (RAC). A moderate compressive strength concrete made with usual fine and coarse aggregate was used as a benchmark material. Compressive and split tensile tests were performed using 120 cylindrical concrete specimens with 150 mm diameter and 300 mm length. Four-point flexural tests in reinforced beams made with conventional concrete and RAC were performed. The results obtained showed that the use of recycled fine aggregates, in both percentages of substitution investigated—50% and 100%—did not generate any deleterious influence on the values of compressive strength and split tensile strength of the RACs produced. Tin fact, the mechanical strengths of RACs produced with recycled fine aggregate were equal or higher than those from the reference concrete. The same behavior was not observed, however, when the recycled coarse aggregate was used. For this case, decreases in concrete mechanical strengths were observed, especially in compressive strength, with values around 35% lower when compared to the reference concrete. Tensile mechanical tests results confirmed the excellent behavior of all RACs made with replacement of usual fine aggregates by recycled. Bending tests performed in reinforced RAC beams had as objective to evaluate the deformation profile of the beams. The obtained results showed that RAC beams with full replacement of usual fine aggregate by the recycled aggregates have presented little changes in the global behavior, an aspect that encourages its use.
The environmental problems caused by sewage sludge generated by the growth of the global population and urbanization are drawing the attention of the scientific community worldwide to the need of developing sustainable solutions to use that material. This work investigated the possibilities of using sewage sludge, generated in wastewater treatment plants, as a strategy to improve and stabilize collapsible soils. Different soil–sludge mixtures, with 5%, 10%, and 15% of sludge, were analyzed. For the characterization and analysis of the soil–sludge interaction, physical, chemical, and edometric experiments were performed. The results showed that the addition of sludge to the soil causes a void index reduction, improves particle packaging, and reduces soil collapsibility to the same specific dry apparent weights, i.e., showed to be a promising method for the improvement of collapsible soils.
This work analyzes the use of sewage sludge, generated in wastewater treatment plants, as an alternative for small aggregate to be used in concrete. Concrete cylindrical specimens with height h = 20 cm and diameter D = 10 cm were prepared using different amounts of sludge in the substitution of fine aggregates. Portland cement (CP II Z 32 RS cement) was used in all concrete mixtures, and two water-cement ratios and four cement-sludge mixtures were investigated. Compressive strength, sclerometer index, ultrasonic wave transmission velocity, and water absorption capillary tests were performed. The results showed that the use of sewage sludge as a replacement for fine aggregate to produce concrete exhibited a positive effect on both its compressive strength and its capillary water absorption. The results, even preliminary ones, demonstrated that the sludge could be used as an effective replacement for fine aggregate to produce concrete. The replacement of fine aggregate with 5% sewage sludge proved to be the optimal replacement value for the type of sewage sludge investigated.
Detailed information about concrete behavior in real structures is an important issue in controlling its performance during its service life, and the use of embedded sensors to obtain desired information such as temperature, onset of the cracking process and evolution of strains, has gained the attention of the building concrete industry. Data obtained using this technology can provide valuable information for decision making about the need for corrective interventions that can ensure the integrity and safety of concrete structures for long period of time. This paper presents a review of the current state-of-the-art of embedded fiber optic sensors used to assess concrete information of a wide range of aspects, comprising: existing alternative technologies, characteristics and advantages, practical applications and future developments. Complementarily, the work presents preliminary results of the use of fiber optic sensors to automatically and continuously perform expansion readings of AAR in concrete elements that facilitate both the storage—with elimination of the usual interruptions for manual readings—and the availability of continuous results of expansion data that are not possible to obtain with usual AAR tests code reading recommendations.
31 August 2018 in Construction and Building Materials