Chiara Romano

Mrs. Chiara Romano

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
CRChiara Romano
Chiara Romano
Emiliano SchenaEmiliano Schena
Emiliano Schena
SSSergio Silvestri
Sergio Silvestri
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Respiratory monitoring is receiving growing interest in different fields of use, ranging from healthcare to occupational settings. Only recently, non-contact measuring systems have been developed to measure the respiratory rate (fR) over time, even in unconstrained environments. Promising methods rely on the analysis of video-frames features recorded from cameras. In this work, a low-cost and unobtrusive measuring system for respiratory pattern monitoring based on the analysis of RGB images recorded from a consumer-grade camera is proposed. The system allows (i) the automatized tracking of the chest movements caused by breathing, (ii) the extraction of the breathing signal from images with methods based on optical flow (FO) and RGB analysis, (iii) the elimination of breathing-unrelated events from the signal, (iv) the identification of possible apneas and, (v) the calculation of fR value every second. Unlike most of the work in the literature, the performances of the system have been tested in an unstructured environment considering user-camera distance and user posture as influencing factors. A total of 24 healthy volunteers were enrolled for the validation tests. Better performances were obtained when the users were in sitting position. FO method outperforms in all conditions. In the fR range 6 to 60 breaths/min (bpm), the FO allows measuring fR values with bias of −0.03 ± 1.38 bpm and −0.02 ± 1.92 bpm when compared to a reference wearable system with the user at 2 and 0.5 m from the camera, respectively.

6 October 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
CRChiara Romano
Chiara Romano
Emiliano SchenaEmiliano Schena
Emiliano Schena
Domenico FormicaDomenico Formica
Domenico Formica
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
The demand for wearable devices to simultaneously monitor heart rate (HR) and respiratory rate (RR) values has grown due to the incidence increase in cardiovascular and respiratory diseases. The use of inertial measurement unit (IMU) sensors, embedding both accelerometers and gyroscopes, may ensure a non-intrusive and low-cost monitoring. While both accelerometers and gyroscopes have been assessed independently for both HR and RR monitoring, there lacks a comprehensive comparison between them when used simultaneously. In this study, we used both accelerometers and gyroscopes embedded in a single IMU sensor for the simultaneous monitoring of HR and RR. The following main findings emerged: (i) the accelerometer outperformed the gyroscope in terms of accuracy in both HR and RR estimation; (ii) the window length used to estimate HR and RR values influences the accuracy; and (iii) increasing the length over 25 s does not provide a relevant improvement, but accuracy improves when the subject is seated or lying down, and deteriorates in the standing posture. Our study provides a comprehensive comparison between two promising systems, highlighting their potentiality for real-time cardiorespiratory monitoring. Furthermore, we give new insights into the influence of window length and posture on the systems’ performance, which can be useful to spread this approach in clinical settings.

8 June 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
CRChiara Romano
Chiara Romano
Andrea NicolòAndrea Nicolò
Andrea Nicolò
LILorenzo Innocenti
Lorenzo Innocenti
MBMarco Bravi
Marco Bravi
SMSandra Miccinilli
Sandra Miccinilli
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Emerging evidence suggests that respiratory frequency (fR) is a valid marker of physical effort. This has stimulated interest in developing devices that allow athletes and exercise practitioners to monitor this vital sign. The numerous technical challenges posed by breathing monitoring in sporting scenarios (e.g., motion artifacts) require careful consideration of the variety of sensors potentially suitable for this purpose. Despite being less prone to motion artifacts than other sensors (e.g., strain sensors), microphone sensors have received limited attention so far. This paper proposes the use of a microphone embedded in a facemask for estimating fR from breath sounds during walking and running. fR was estimated in the time domain as the time elapsed between consecutive exhalation events retrieved from breathing sounds every 30 s. Data were collected from ten healthy subjects (both males and females) at rest and during walking (at 3 km/h and 6 km/h) and running (at 9 km/h and 12 km/h) activities. The reference respiratory signal was recorded with an orifice flowmeter. The mean absolute error (MAE), the mean of differences (MOD), and the limits of agreements (LOAs) were computed separately for each condition. Relatively good agreement was found between the proposed system and the reference system, with MAE and MOD values increasing with the increase in exercise intensity and ambient noise up to a maximum of 3.8 bpm (breaths per minute) and −2.0 bpm, respectively, during running at 12 km/h. When considering all the conditions together, we found an MAE of 1.7 bpm and an MOD ± LOAs of −0.24 ± 5.07 bpm. These findings suggest that microphone sensors can be considered among the suitable options for estimating fR during exercise.

2 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MČMilena Čukić
Milena Čukić
CRChiara Romano
Chiara Romano
Francesca De TommasiFrancesca De Tommasi
Francesca De Tommasi
CMCarassiti Massimiliano
Carassiti Massimiliano
Domenico FormicaDomenico Formica
Domenico Formica
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Heart rate variability (HRV) indexes are becoming useful in various applications, from better diagnosis and prevention of diseases to predicting stress levels. Typically, HRV indexes are retrieved from the heart’s electrical activity collected with an electrocardiographic signal (ECG). Heart-induced mechanical signals recorded from the body’s surface can be utilized to record the mechanical activity of the heart and, in turn, extract HRV indexes from interbeat intervals (IBIs). Among others, accelerometers and gyroscopes can be used to register IBIs from precordial accelerations and chest wall angular velocities. However, unlike electrical signals, the morphology of mechanical ones is strongly affected by body posture. In this paper, we investigated the feasibility of estimating the most common linear and non-linear HRV indexes from accelerometer and gyroscope data collected with a wearable skin-interfaced Inertial Measurement Unit (IMU) positioned at the xiphoid level. Data were collected from 21 healthy volunteers assuming two common postures (i.e., seated and lying). Results show that using the gyroscope signal in the lying posture allows accurate results in estimating IBIs, thus allowing extracting of linear and non-linear HRV parameters that are not statistically significantly different from those extracted from reference ECG.

19 April 2023 in IEEE Transactions on Dependable and Secure Computing
Verified
Journal Article
Open access
EMEmanuele Maiorana
Emanuele Maiorana
CRChiara Romano
Chiara Romano
Emiliano SchenaEmiliano Schena
Emiliano Schena
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Wearable devices have been recently proposed to perform biometric recognition, leveraging on the uniqueness of the collectable physiological traits to generate discriminative identifiers. Most of the studies conducted on this topic have exploited heart-related signals, sensing the cardiac activity either through electrical measurements using electrocardiography, or with optical recordings employing photoplethysmography. In this paper we instead propose a system performing BIOmetric recognition using Wearable Inertial Sensors detecting Heart activity (BIOWISH). In more detail, we investigate the feasibility of exploiting mechanical measurements obtained through seismocardiography and gyrocardiography to verify the identity of a subject. Several feature extractors and classifiers, including deep learning techniques relying on siamese training, are employed to derive distinctive characteristics from the considered signals, so as to differentiate between legitimate users and impostors. A multi-session database, comprising acquisitions taken from subjects performing different activities, is employed to perform experimental tests. The obtained results testify that identifiers derived from measurements of chest vibrations, collected by wearable inertial sensors, could be employed to guarantee high recognition performance, even when considering short-time recordings. Explainability methods have been also employed to derive some insights about the aspects relevant to perform predictions for both people and activity recognition tasks.

21 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
CRChiara Romano
Chiara Romano
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
SSSergio Silvestri
Sergio Silvestri
Emiliano SchenaEmiliano Schena
Emiliano Schena
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Respiratory rate (fR) monitoring through wearable devices is crucial in several scenarios, providing insights into well-being and sports performance while minimizing interference with daily activities. Strain sensors embedded into garments stand out but require thorough investigation for optimal deployment. Optimal sensor positioning is often overlooked, and when addressed, the quality of the respiratory signal is neglected. Additionally, sensor metrological characterization after sensor integration is often omitted. In this study, we present the design, development, and feasibility assessment of a smart t-shirt embedded with two flexible sensors for fR monitoring. Guided by a motion capture system, optimal sensor design and position on the chest wall were defined, considering both signal magnitude and quality. The sensors were developed, embedded into the wearable system, and metrologically characterized, demonstrating a remarkable response to both static (sensitivity 9.4 Ω⋅%−1 and 9.1 Ω⋅%−1 for sensor A and sensor B, respectively) and cyclic loads (min. hysteresis span 20.4% at 36 bpm obtained for sensor A). The feasibility of the wearable system was assessed on healthy volunteers both under static and dynamic conditions (such as running, walking, and climbing stairs). A mean absolute error of 0.32 bpm was obtained by averaging all subjects and tests using the combination of the two sensors. This value was lower than that obtained using both sensor A (0.53 bpm) and sensor B (0.78 bpm) individually. Our study highlights the importance of signal amplitude and quality in optimal sensor placement evaluation, as well as the characterization of the embedded sensors for metrological assessment.