Grid-forming inverters can establish frequency and voltage regulation in autonomous microgrids by themselves without relying on the external grid and as such are significant enablers for the integration of inverter-interfaced renewable energy sources. The most prominent grid-forming strategies, the droop-based techniques, cannot provide an error-free frequency regulation after a step-wise disturbance and thus are completed by the secondary integral action. In this paper, we propose a model predictive control for fast frequency response in an AC, purely inverter-based microgrid operating in islanded mode. The controller acts as a secondary control unit and adjusts the control actions of the underlying droop controllers leading to an error-free frequency transient control. The controller has been designed leveraging the concept of frequency divider - a simple analytical formulation that estimates the frequency at every system bus. The proposed control is successful in providing a fast frequency response, i.e., it assures a system-wide error-free frequency regulation under different operating circumstances including load changes and varying X/R-ratios. Numerical simulations are carried out in the WSCC 9-Bus and IEEE 39-Bus systems to verify the performance of the proposed method during transients and a comparison with respect to the more common secondary frequency control is given.
17 December 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
DC microgrids require advanced protection techniques for fault detection and isolation (FDI). In this work, an FDI method able to respond to different types of component faults is developed based on system modeling. First, the state-space representation of a multi-terminal DC microgrid with component faults is derived. Then, an FDI function based on H-/H∞ observers is designed. To achieve the desired selectivity in fault isolation, the linear matrix inequality (LMI) optimization approach is adopted in the observer design. The performance of the proposed FDI method is verified under the real-time (RT) simulation of a three-terminal low voltage DC microgrids and with a small-scale laboratory DC grid. The proposed FDI method is proved to be effective to detect and isolate different faults in DC microgrids with a response time of 1 ms.
The Andronov-Hopf based Virtual Oscillator Control (AHO) is an emerging control strategy for grid-forming converters (GFC) to ensure the stability of the future power system with high level of penetration of renewable energies. AHO allows converters to operate in either grid-connected and islanded operating modes. However, the application of this control strategy is limited due to the inherent problem in simultaneous controlling active and reactive power output of GFCs. This paper presents a modification in AHO control structure, and adopts a wide-band grid impedance estimation to improve the dispatchability of AHO in grid-connected mode. The impedance estimation algorithm is embedded into the control loop of AHO, and requires only the measurement of the voltages and currents at the point of common coupling. Thus it is cost-effective and practical. The performance of the proposed method is validated in both simplestructure, and large low-voltage benchmark distribution systems, using MATLAB/Simulink software and the real-time Opal-RT platform. The simulation results confirm the high-accuracy of the estimation and the capability of AHO in simultaneously controlling active and reactive power with zero steady-state errors. Additionally, this paper discusses the small-signal stability and Lyapunov large signal stability of the proposed AHO and compares it to existing methods.
Modelling the fast dynamics of power converters is of growing concern in power grids and Microgrids. Dynamic phasor (DP) concept has been widely applied to switched power converter for modelling fast transients efficiently due to the inherent frequency shift property of DPs. The dynamics introduced by the DC/AC power converters depend on the controllers, which are implemented either in the stationary frame or on the synchronous reference frame (SRF). Hybrid closed-loop modelling methods that consider DP-based power converter plant model are not established and the applicability and accuracy of such hybrid approaches are not fully understood. This paper attempts to address this gap by proposing two hybrid closed-loop modelling approaches: Hybrid DP-DQ and Hybrid DP-EMT and discusses the applicability and accuracy for various controller types. Furthermore, this paper presents a DP switched model of single and three phase two level power converter and discusses the selection of harmonics to reduce model complexity. The proposed hybrid approaches were validated against detailed switched power converter models and for a wide range of scenarios, the Hybrid DP-EMT method is found to be superior compared other methods. Finally, application dependent recommendations are made for the selection of suitable hybrid closed-loop model for the accurate simulation of single phase and three phase power converters.
The increasing dominance of inverter-based resources (IBRs) in power generation leads to significantly faster frequency dynamics in modern power systems. Therefore, the secondary control within the classical hierarchical structure must operate significantly faster. However, high communication burdens are inherent to centralized implementations of secondary control. This paper proposes a faster, distributed model predictive control (MPC) scheme for secondary frequency control of inverter-based power systems. The controller predicts the IBRs’ local frequency dynamics by considering the impact of the primary control of nearby IBRs. To obtain an optimal model-predictive control problem consisting of distributable subproblems, we introduce a novel trimming procedure to the frequency divider concept, an analytical formulation that estimates the local frequency at system buses. These subproblems have a tunable degree of mutual coupling. The presented distributed MPC achieves fast, error-free frequency regulation in the presence of abrupt load changes while also being robust to communication losses of participating IBRs. By design, the distributed control relies on a sparse neighbor-to-neighbor communication structure and uses local MPC problems that do not scale in complexity with system size. Numerical simulations of the IEEE 39-bus system and an extended CIGRE medium voltage power system demonstrate the fast performance of the proposed distributed MPC scheme for secondary frequency control.
17 November 2023 in IEEE Transactions on Power Systems
It is well known in the power system community that frequency is not a global variable during transients. The previously proposed frequency divider (FD) is a valid approach to estimate load bus frequencies in large transmission networks wherein the load dynamics are typically ignored. In converter-driven grids, load dynamics may have a significant impact on the local frequency dynamics. This article determines that the FD has low accuracy under such conditions. This paper proposes a centralized dynamic phasor estimator (DPE) to track the frequency of the load buses and additionally estimate the branch current phasors and load bus voltage phasors. The key idea is to formulate the power system state-space model in the dynamic phasor domain such that grid-forming converter (GFC) bus voltage phasors and load power measurements are inputs and the load bus voltage and branch current phasors as states. The dynamic phasor of the GFC bus voltage is calculated by measuring the terminal voltage of the GFC bus and the internal frequency available within the droop-control loop of the GFC. A complex-PLL (C-PLL) is proposed to track the rotation of the load bus voltage phasors to estimate the actual frequency at the load buses. Numerical simulations are carried out on the modified WSCC 9-bus system and the IEEE 39-bus system to demonstrate the effectiveness of the proposed method.