Burde Alexandru

Dr. Burde Alexandru

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
MBMichel Beyer Michel Beyer
Michel Beyer Michel Beyer
LSLena Scheller
Lena Scheller
BABurde Alexandru
Burde Alexandru
SASead Abazi
Sead Abazi
ASAdelita Sommacal
Adelita Sommacal
Florian Markus ThieringerFlorian Markus Thieringer
Florian Markus Thieringer
Background: Three-dimensional (3D) printing technologies such as Stereolithography (SLA) and Digital Light Processing (DLP) are widely used in dental implantology for the fabrication of surgical guides. While both methods offer clinical viability, their comparative accuracy, efficiency, and material consumption remain subjects of debate. Objectives: To compare the dimensional accuracy, printing time, and material consumption of dental surgical guides fabricated using an SLA printer (Formlabs Form 3B) and a DLP printer (NextDent 5100) at various printing orientations. Methods: A standardized surgical guide was designed and printed on both printers across seven orientations (0–90°). Five guides per angle were fabricated per technology (n = 35 per printer), scanned, and compared with the CAD reference to evaluate dimensional accuracy. Printing time and resin consumption were recorded. Statistical analyses included the Shapiro–Wilk test and Mann–Whitney U test (α = 0.05). Results: Within the evaluated printers and resins, SLA-printed guides demonstrated slightly lower Root Mean Square (RMS) values in most regions, especially in occlusal and drill hole surfaces, while DLP guides tended to undersize Optimal accuracy was observed at 45° for SLA and 60° for DLP. Material consumption was lower for the SLA printer compared with the DLP printer, but SLA required longer printing time (90–200 min vs. 25–75 min for DLP). Conclusions: Both technologies produced clinically acceptable guides under the tested conditions. The tested SLA printer tended to offer slightly higher accuracy and material efficiency, whereas the DLP printer achieved shorter printing times, supporting its use in high-throughput workflows. Printing orientation significantly influenced accuracy and resource use.

16 March 2022 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Closed access
MMManuela Maria Manziuc
Manuela Maria Manziuc
Cristina GasparikCristina Gasparik
Cristina Gasparik
BABurde Alexandru
Burde Alexandru
JRJavier Ruiz-López
Javier Ruiz-López
Smaranda BuduruSmaranda Buduru
Smaranda Buduru
DDDiana Dudea
Diana Dudea

20 April 2021 in Coatings
Verified
Journal Article
Open access
PDF file
Stanca CucStanca Cuc
Stanca Cuc
BABurde Alexandru
Burde Alexandru
Cosmin CosmaCosmin Cosma
Cosmin Cosma
DLDanut Vasile Leordean
Danut Vasile Leordean
MRMircea Aurelian Rusu
Mircea Aurelian Rusu
RERazvan Ene
Razvan Ene
This study was concerned with the adhesion of resin cement to metal surfaces obtained by selective laser melting process (SLM), and how it could be improved the bond strength at the biocomposite-metal junction. The SLM substrates were manufactured out of pure titanium (Ti), Ti6Al7Nb, and CoCr alloys. The metallic surfaces were covered with 5 types of biocomposites: 2 commercially resin-modified glass-ionomer cements (GC Fuji Plus and KETAC CEM) and 3 types of in-house developed materials. These biocomposites were mechanical characterized under compression and bending trials. The biocomposites-metal adhesion was settled both on as built metallic surfaces and after they were sandblasted with alumina. All the sandblasted SLM surfaces presented higher adhesion strength in comparison with the untreated specimens. The CoCr specimens show the highest bonding value. Additionally, the morphological aspects of joining interfaces were investigated using a scanning electron microscope (SEM). The mechanical properties and metal adhesion of these biocomposites were influenced by the liquid powder ratio. It is essential to apply a surface treatment on SLM substrate to achieve a stronger bond. Also, the chemical composition of biocomposite is a major factor which may improve the adhesion of it on different metallic substrates.

31 August 2025 in Medicina
Verified
Journal Article
Open access
PDF file
MMMarius Ciprian Manole
Marius Ciprian Manole
MNMihnea Ionuț Nicoară
Mihnea Ionuț Nicoară
BABurde Alexandru
Burde Alexandru
IHIoana Hedesiu
Ioana Hedesiu
DBDan Nicolae Bele
Dan Nicolae Bele
Meda-Lavinia NegrutiuMeda-Lavinia Negrutiu
Meda-Lavinia Negrutiu
Background and Objectives: Medication-related osteonecrosis of the jaw (MRONJ) is a serious complication of antiresorptive and antiangiogenic therapies. Early and accurate imaging is crucial for diagnosis and management. This review summarizes the current evidence on MRONJ imaging findings across modalities and identifies gaps for future research. Materials and Methods: This narrative review analyzed 32 studies (2010–2024) retrieved from PubMed and EBSCO examining imaging findings and diagnostic patterns of medication-related osteonecrosis of the jaw across different modalities. Two independent reviewers screened all articles, extracted data, and assessed methodological quality. Results: Early-stage MRONJ findings included osteosclerosis, lamina dura thickening, and increased prominence of the inferior alveolar canal, while late-stage findings included periosteal reactions, sequestration, and cortical erosion. CBCT and MRI were most sensitive for early detection and lesion extent. However, substantial variability in imaging protocols limited direct comparisons between studies. Conclusions: This review highlights the variable imaging findings of MRONJ and the need for standardized protocols. Advanced imaging techniques and quantitative indices hold promise for improving early diagnosis, staging, and management.

25 November 2021 in Medical Ultrasonography
Verified
Journal Article
Closed access
PDF file
MDMarina Dudea-Simon
Marina Dudea-Simon
Sorin Marian DudeaSorin Marian Dudea
Sorin Marian Dudea
CSCalin Schiau
Calin Schiau
RCrazvan ciortea
razvan ciortea
DCDelia Clinciu
Delia Clinciu
DMDan Mihu
Dan Mihu
Aims: To analyse the intra- and interobserver variability of two elastographic methods of quantification available on the same machine, the technical factors that may influence variability as well as the intra- and interobserver variability for the same indices between two different ultrasound machines in an in vitro experimental setting.Material and methods: Three different types of silicone experimental devices (ED) were conceived for the purpose of this study. Two observers performed repeated measurements on two ultrasound machines. Strain elastography, with strain ratio determination between the ED was performed on both machines. Shear wave ratio was also assessed. The data obtained were used to calculate intra- and interobservervariability. Reproducibility was assessed in relation to the size of the elastographic region of interest (ROI) and to the difference in stiffness between the ED, through the value of the ICCs (Intraclass Correlation Coefficient).Results: Strain ratio had high inter- and intraobserver reproducibility, regardless of the machine used, on a large number of determinations.The choice of a small ROI diameter (5 mm) over a large ROI diameter (15mm) increased reproducibility (ICC = 0.87 vs 0.78, p=0.000). It is observed that, by Shear Wave Elastography, only when analysing structures with a large difference in hardness, significance is obtained in terms of interobserver reproducibility (ICC = 0.75, p=0.000).Conclusions: On a large number of determinations, both techniques are inter- and intraobserver reproducible. It is preferable to opt for a smaller ROI diameter in order to increase interobserver reproducibility. SWE Ratio provides significant reproducibility only when analysing structureswith large difference in hardness.

21 January 2026 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
ALAnca Labunet
Anca Labunet
Andreea KuiAndreea Kui
Andreea Kui
AVAlexandra Vigu
Alexandra Vigu
AVAndrada Feliciana Voina-Tonea
Andrada Feliciana Voina-Tonea
BABurde Alexandru
Burde Alexandru
SSSorina Andrea Sava
Sorina Andrea Sava
Background and Objectives: Preheated composite resins have been proposed as an alternative to conventional luting agents due to their improved resistance, color stability, and adaptation. This review aims to critically evaluate the current literature on the use of preheated composites as luting agents exclusively on dentin and enamel, focusing on their mechanical behavior, optical properties, and biological effects, in order to determine whether they provide superior clinical outcomes compared with conventional resin cements. Materials and Methods: A comprehensive literature search from 2015 to 2025 was conducted in accordance with PRISMA-ScR guidelines. Eligible studies included in vitro investigations comparing the preheated composite with other luting agents performed on human, bovine, analog dentin or enamel substrates. Studies meeting these criteria were screened, evaluated, and synthesized. Results: Fifteen studies met the inclusion criteria: nine focused on the mechanical performance, and the remaining six studies examined additional properties such as color stability, pulpal temperature changes during preheating, film thickness characteristics, and the influence on marginal discrepancy. Conclusions: Preheated composite resins offer improved mechanical properties, marginal adaptation, and fracture resistance compared with conventional luting agents. However, their performance is highly technique-sensitive, and clinical outcomes depend on operator skill, restoration thickness, and material selection. Preheating generally does not compromise color stability, but it can elevate pulpal temperature, particularly when residual dentin is thin. Overall, preheated composites have potential clinical advantages, provided that careful handling and appropriate application are ensured.