Representative Publications

View All Publications
14 October 2022 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
JKJaewon Kim
Jaewon Kim
JJJin Ho Jung
Jin Ho Jung
YCYong Choi
Yong Choi
JJJiwoong Jung
Jiwoong Jung
SLSangwon Lee
Sangwon Lee

25 June 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
JJJiwoong Jung
Jiwoong Jung
YCYong Choi
Yong Choi
KKKyu Bom Kim
Kyu Bom Kim
SLSangwon Lee
Sangwon Lee
HCHyeok-Jun Choe
Hyeok-Jun Choe
The time over threshold (TOT) method has been recently proposed as a signal processing method used to calculate time and energy information by measuring the pulse arrival time and pulse duration over a preset threshold. Although TOT has been reported as an effective method for front end readout in PET applications, it has several limitations, including its non-linearity, lower dynamic range, and a trade-off between energy resolution and coincidence resolving time (CRT). In this study, we propose a novel design we developed to improve performance with regard to these problems occurring in the conventional TOT by employing a bipolar signal and two comparators. Using a high frequency CR shaping filter, a detected signal was converted into a bipolar signal, and the positive pulse of the converted bipolar signal had a fast rising time, while the negative pulse had a linear slope. The bipolar TOT circuit was composed of a preamplifier, a CR shaping filter, and two comparators. The PET detector was composed of a single LYSO coupled with 4 × 4 SiPM arrays, a bipolar TOT circuit, and an FPGA based TDC. And this was constructed to evaluate the performance of the proposed bipolar TOT method. A 16-ch PET detector module consisting of a 4 × 4 array LYSO coupled to a 4 × 4 SiPM arrays, an Anger logic discretized positioning circuit, and a 4-ch bipolar TOT circuit was also constructed to evaluate the functionality of the bipolar TOT method for PET applications. The pulse height resolution and CRT were measured using both the bipolar TOT method and the conventional TOT method. While the bipolar TOT method provided a similar pulse height resolution (10.4% ± 0.1%), the integral non-linearity (1.4%) and CRT (168 ± 4 ps) measured using the bipolar TOT method were greatly improved compared to those (17.2% and 258 ± 15 ps, respectively) measured with the conventional TOT method. The positions of the crystals were clearly identified, as seen in the flood histogram acquired using the 4-ch bipolar TOT circuit. The measured average pulse height resolution and average CRT for the 16-ch detector module were 11.5% ± 0.2% and 516 ± 24 ps. The results obtained in this study indicate that the bipolar TOT method requiring a relatively small number of electronic components could effectively improve the CRT, linearity and dynamic range. Furthermore, they also demonstrated the extendibility allowing the development of a PET system that consists of a large number of detectors.

10 February 2022 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
HLHyuntae Leem
Hyuntae Leem
YCYong Choi
Yong Choi
JJJiwoong Jung
Jiwoong Jung
Kuntai ParkKuntai Park
Kuntai Park
YKYeonkyeong Kim
Yeonkyeong Kim
JJJin Ho Jung
Jin Ho Jung

13 September 2021 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
JJJiwoong Jung
Jiwoong Jung
YCYong Choi
Yong Choi
Kuntai ParkKuntai Park
Kuntai Park
YKYeonkyeong Kim
Yeonkyeong Kim
JJJin Ho Jung
Jin Ho Jung
Multiplexing circuits in pixelated PET detectors are being studied with the goal of minimizing the degradation of detector performance. The purpose of this study was to develop a diode-based symmetric charge division (SCD) circuit with reducing the crosstalk caused by the leakage currents of adjacent channels connected in rows and columns. Four different SCD circuits (diode-based SCD with grounding path, diode-based SCD, resistor-based SCD with grounding path, and resistor-based SCD) were constructed and their performance was evaluated and compared after being combined with a PET detector consisting of Lutetium Yttrium Orthosilicate crystals optically coupled with SiPM. The diode-based SCD circuit with grounding path achieved a crosstalk ratio, energy resolution, coincidence timing resolution (CTR), and mean peak to valley ratio of 0.02, 14.3%, 0.5 ns, and 27.9: 1, respectively; the diode-based SCD circuit achieved 0.03, 15.9%, 0.7 ns, and 19.4: 1, respectively; the resistor-based SCD circuit with grounding path achieved 0.04, 14.5%, 0.9 ns, and 19.4: 1, respectively; and the resistor-based SCD circuit achieved 0.05, 17.8%, 1.8 ns, and 17.7: 1, respectively. These results indicate that the proposed SCD has the potential to improve not only the crosstalk but also the energy linearity, energy resolution, and CTR characteristics in PET detectors.

13 February 2024 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
JJJin Ho Jung
Jin Ho Jung
YCYong Choi
Yong Choi
JYJohyeon Yun
Johyeon Yun
JJJiwoong Jung
Jiwoong Jung
SLSangwon Lee
Sangwon Lee

1 February 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
SLSangwon Lee
Sangwon Lee
YCYong Choi
Yong Choi
JJJin Ho Jung
Jin Ho Jung
JJJiwoong Jung
Jiwoong Jung
KKKyu Bom Kim
Kyu Bom Kim
YHYong-Min Huh
Yong-Min Huh
Small animal positron emission tomography (PET) is a noninvasive imaging modality that enables in vivo imaging and quantification of the biological processes of small experimental animals. We have developed a small animal PET that utilizes a high-resolution multiplexed readout and charge signal transmission (CST) method. The small animal PET was composed of six detector blocks consisting of SiPMs and LYSO arrays. Six detector blocks were mounted on a PET gantry having an inner diameter of 76 mm, outer diameter of 112 mm, and axial length of 40.8 mm. The charge signals of SiPM output were transmitted to the input of multiplexed readout using 4 m flexible flat cables. The multiplexed readout was composed of six main boards, each of which included 36 detector boards, to reduce the number of readout channels by a factor of 36, with a multiplexing ratio of 144:4. The performance of the small animal PET was evaluated using NEMA NU 4-2008 standards, and its imaging capability was demonstrated by in vivo mouse imaging studies. The average energy and time resolutions were 13.2% ± 0.3% and 3.8 ns, respectively. The spatial resolution at the center of the transaxial FOV was 1.1 mm, and the peak sensitivity at the center of the axial FOV was 1.5%. The peak noise equivalent count (NEC) rate and scatter fraction were 21.1 kcps at 18.2 MBq and 21%, respectively. The acquired images demonstrated high quality tracer uptake patterns of small experimental animals. The results of performance evaluation and animal imaging indicate that the small animal PET developed in this study can provide high-quality small animal imaging with cost-effectiveness and compactness.